  • Hello! I've reviewed the provided installation manual for the NORAC Severe Terrain Option Low Profile brackets. This manual includes detailed instructions for installing the brackets, setting up the ultrasonic sensors, and performing the electrical connections. I'm ready to help answer any questions you may have about the installation process and the guidelines for optimal sensor performance.
  • Where should I mount the sensor brackets?
    What is the recommended torque for the M8 nut when mounting the sensor?
    Is it recommended to use dielectric grease on electrical connections?
    What should I apply to the threaded parts during installation?

SevereTerrainOption
LowProfileBrackets
InstallationManual
Copyright2023byNORACSystemsInternationalInc.
ReorderP/N:7465BCLPINSTRevC(SevereTerrainOptionLowProfileBrackets)
NOTICE:NORACSystemsInternationalInc.reservestherighttoimproveproductsandtheirspecificationswithoutnoticeandwithouttherequirementtoupdate
productssoldpreviously.Everyefforthasbeenmadetoensuretheaccuracyoftheinformationcontainedinthismanual.Thetechnicalinformationinthismanual
wasreviewedatthetimeofapprovalforpublication.
WWW.NORAC.CA
PRECISIONDEFINED
Contents
1
Introduction..........................................................................................................................1
2
PartsOverview......................................................................................................................2
3
UltrasonicSensorInstallation................................................................................................4
4
ElectricalInstallation.............................................................................................................8
5
SoftwareSetup......................................................................................................................9
6
CableDrawings....................................................................................................................10

WWW.NORAC.CA
PRECISIONDEFINED

Page1
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
1 Introduction
Pleasetakethetimetoreadthismanualcompletelybeforeattemptingtoinstallthesystem.Athorough
understandingofthismanualwillensurethatyoureceivethemaximumbenefitfromthesystem.
Yourinputcanhelpmakeusbetter!Ifyoufindissuesorhavesuggestionsregardingthepartslistorthe
installationprocedure,pleasedon’thesitatetocontactus.
Everyefforthasbeenmadetoensuretheaccuracyoftheinformationcontainedinthismanual.Allparts
suppliedareselectedtospeciallyfitthesprayertofacilitateacompleteinstallation.However,NORACcannot
guaranteeallpartsfitasintendedduetothevariationsofthesprayerbythemanufacturer.
Pleasereadthismanualinitsentiretybeforeattemptinginstallation.
Donotusehighspeedpowertools/drillswheninstallinghardware.
TheuseofdielectricgreaseisnotrecommendedonanyNORACelectricalconnections.
ToensureallstainlesssteelhardwaredoesnotgallorseizeapplyalightcoatingofthesuppliedPermatex
Antiseizegreasetoallthreadedpartsuponinstallation.PermatexAntiseizelubricantispreferred,butother
similarantiseizeproductsmaybeused.
WWW.NORAC.CA
PRECISIONDEFINED

Page2
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
2 PartsOverview
2.1. KitOverview
Figure1:SevereTerrainParts
*SevereTerrainOptionKitsforApachesprayersincludetwospacers(B12).
WWW.NORAC.CA
PRECISIONDEFINED

Page3
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
2.2. ListofParts
ItemPartNumberNameQuantity
B054470601KITCABLETIEBLACK10PCS21IN150PCS7.5IN1
B2044971SENSORMOUNTINGBRACKETLOWPROFILE16GA2
C064321010CABLENETWORK18AWG10M2
E0750300MAXSENSOR2
E1043760NETWORKCOUPLER3WAY2
M027465BC‐LPINSTMANUALINSTALLATIONSEVERETERRAINOPTIONLOWPROFILE 1
2.3. AdditionalPartsforApacheSprayers
ItemPartNumberNameQuantity
B1244747SPACER2INSQUARETUBING8IN2
WWW.NORAC.CA
PRECISIONDEFINED

Page4
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
3 UltrasonicSensorInstallation
3.1. UltrasonicSensorSerialNumberArrangement
Wheninstallingtheultrasonicsensors,startwiththesmallestserialnumberonthelefthandside,andproceed
tothelargestserialnumberontherighthandside.Eachultrasonicsensorhasaserialnumberstampedonthe
sensorhousing.
ApplyalightcoatingofthesuppliedPermatexAntiseizegreasetoallthreadedpartsuponinstallation.
Figure2:SensorSerialNumberArrangement
 Onlythecomponentsshowninblackareincludedinthiskit.
WWW.NORAC.CA
PRECISIONDEFINED

Page5
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
3.2. WingSensorInstallation
1. Thesensorbracketshouldbeorientedforward(aheadoftheboom).
2. Mountthesensorbracketsontotheboomhalfwaybetweenthetipandcenterofthesprayer.
3. MounttheMAXsensorintothesensorbracket.TorquetheM8nutto108inlb(12Nm).Runthesensor
cableeitherthroughholeinthebackorthroughthesidecutoutandbehindthebracket.Ensurethecable
isclearofmovingpartsandwillnotbedamagedduringfolding.
 
Figure3:BracketMountingExample
4. IfinstallingtheSevereTerrainOptiononanApachesprayer,spacers(B12)mustbeusedtomountthe
bracketonthelowestpartoftheboom.Thespacermustbeplacedbetweenthelowestpartoftheboom
andthebackfaceofthebracket.Theplatewouldthenbeplacedbehindtheboom.(Figure4)
Figure4:ApacheSpacerPlacementonSevereTerrainPackage
Front
Spacer
(B12)
Front
WWW.NORAC.CA
PRECISIONDEFINED

Page6
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
3.3. UltrasonicSensorMountingGuidelines
Thefollowingguidelineswillensureoptimalsensorperformanceandpreventsensormeasurement.
1. Initslowestposition,thesensormustbe9inches(230mm)ormorefromtheground.
2. Ensurethattherearenoobstructionswithina12inch(300mm)diametercircleprojecteddirectlybelow
thecenterofthesensor.
3. Thesensorshouldbeapproximatelyverticalatnormaloperatingheights.
Figure5:SensorMountingGuidelines
Figure6:BracketMountingGuidelines
WWW.NORAC.CA
PRECISIONDEFINED

Page7
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
3.4. LowProfileBracketMountingGuidelines
1. Minimizethedistancebetweentheboltstopreventbendingthebracketandpreventthebracketfrom
looseningovertime.
2. Ensurethebracketismountedtightagainstthebottomoftheboom,minimizingthedistancebetweenthe
boomstructureandtheangledflange.
Aproblemcanariseifasensorisnotmountedcorrectly.Thismayonlybecomeapparentoncethecontrol
systemisswitchedfromsoiltocropmode.
Becarefulthatthesensorbracketdoesnotcollidewithanyotherpartoftheboomwhentheboomisfolded
totransportposition.Ifpossible,mountthesensorbracketswhiletheboomsarefoldedtoensuretheywill
notcauseinterference.
WWW.NORAC.CA
PRECISIONDEFINED

Page8
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
4 ElectricalInstallation
1. Removethe2waycouplerwithterminator(E20)fromtheoutersensorandinstallitattheinnersensor.
2. Installthe3waycoupler(E10)attheoutersensor.PlugtheexistingCANbuscable(C05)andthesensor
cableintothe3waycoupler.
3. ConnecttheCANbuscable(C06)betweenthe2waycouplerwithterminator(E20)andthe3waycoupler
(E10).
Onlythecomponentsshowninblackareincludedinthiskit.
Figure7:ElectricalInstallation

WWW.NORAC.CA
PRECISIONDEFINED

Page9
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
5 SoftwareSetup
1. Startupthesprayerandtestthesprayer’sfunctionality.Thecontrolpaneldoesnotneedtobepowered
onfortheoriginalswitchestofunction.
Confirmthatthecablingandhosesareagreeabletotheentirerangeofmotion.
2. Ifanyfunctionsdonotwork,reviewthismanualtocheckforproperinstallation.
3. Turnonthepowerforthecontrolpanelusingtheswitchonthesideofthechassis.
4. RefertotheSprayHeightControlOperator’sManualtorunanautomaticinstall.
WWW.NORAC.CA
PRECISIONDEFINED

Page10
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
6 CableDrawings
6.1. ITEMC06:4321010‐CABLENETWORK18AWG‐10M

WWW.NORAC.CA
PRECISIONDEFINED

Page11
Visitwww.solutions.norac.caformoresystem
installationandtroubleshootinginfo.
 Notes
TOPCONAgricultureCanada
3702KinnearPlace
Saskatoon,SKS7P0A6
TOPCONAgricultureAmericas
W5527Hwy106
FortAtkinson,WI53538
TOPCONPrecisionAgricultureEurope
Avenidadelaindustria,
35,TresCantos,España
Spain
Support
Phone:8889799509
Email:[email protected]
Web:www.norac.ca

/