Securityline
CP4044E - CP4092E - CP8192E
Expanding inputs/outputs
and upgrading features on control units
CP4020 - CP4060 - CP8192
obtained through fi rmware and software
downloaded from www.came.com:
CPxxxxE Firmware version 1.0.12 or superior
SWLINK Software version 1.0.8 or superior
SWFWUPDATER Software version 1.0.8 or superior
Store and refer to this document
along with manual 319V43
SECURITY CONTROL UNITS
UPGRADED VIA SOFTWARE
English EN
9((1
Page
2
- Installers manual code:
319V43E
319V43E ver.
1.0
1.0 - 05/2012 © CAME Cancelli Automatici S.p.A. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.A. to notify said changes.
ENGLISH
Comparison of TECHNICAL CHARACTERISTICS among UPGRADED and BASIC versions of the CP control units
Characteristic CP4044E CP4020 CP4092E CP4060 CP8192E CP8192
Areas 44881616
Scenarios 32 32 32 32 32 32
Total inputs 44 20 92 60 192 192
Wire inputs 20 4 44 20 128 128
Radio inputs 24 16 48 40 64 64
Control unit inputs 444488
Types of control unit inputs NC, NA, SB, DB, CI NC, NA, SB, DB, CI NC, NA, SB, DB, CI NC, NA, SB, DB, CI NC, NA, SB, DB, CI NC, NA, SB, DB, CI
Types of BUS inputs NC, NA, SB, DB, CI NC, NA, SB, DB, CI NC, NA, SB, DB, CI NC, NA, SB, DB, CI NC, NA, SB, DB, CI NC, NA, SB, DB, CI
Onboard relay outputs 112233
Total programmable outputs 20 4 44 20 128 128
Programmable control unit outputs 444488
Programmable bus outputs 16 / 40 16 120 120
Inputs managed expansion modules 2 (See Note 1) / 5 (See Note 2) 1+1 15 (See Note 3) 14+1
Bus outputs expansion modules 2 / 5 2 15 15
Bus radio concentrator modules 2 2 8 8 16 16
Inserters 44881616
Keypads 44881616
Touch Screen Yes No Yes Yes Yes Yes
Transponder keys 20 {(99 with
GV256)
20 {(99 with
GV256)
50 {(999 with
GV256)
50 {(999 with
GV256)
50 {(999 with
GV256)
50 {(999 with
GV256)
Installer's codes 111111
User codes 20 {(99 with
GV256)
20 {(99 with
GV256)
50 {(999 with
GV256)
50 {(999 with
GV256)
50 {(999 with
GV256)
50 {(999 with
GV256)
Radio transmitters 8 8 32 32 32 32
Timer programmer Daily / Weekly Daily / Weekly Daily / {Weekly Daily / Weekly Daily / {Weekly Daily / Weekly
Events 200 {(999 with
GV256)
200 {(999 with
GV256)
999 {(9999 with
GV256)
999 {(9999 with
GV256)
999 {(9999 with
GV256)
999 {(9999 with
GV256)
BUS 485 111122
PSTN combiner Yes Yes Yes Yes Yes Yes
GSM combiner Optional Optional Optional Optional Optional Optional
Voice synthesis Optional Optional Optional Optional Optional Optional
Telephone numbers 8 8 16 16 16 16
CONTACT-ID Yes Yes Yes Yes Yes Yes
Power supply units on BUS 8 8 8 8 16 16
Reprogramming control unit FW Yes Yes Yes Yes Yes Yes
LAN Optional Optional Optional Optional Optional Optional
Control from SMS Yes (with GSM) Yes (with GSM) Yes (with GSM) Yes (with GSM) Yes (with GSM) Yes (with GSM)
Control from VOICE Yes (with GVxx) Yes (with GVxx) Yes (with GVxx) Yes (with GVxx) Yes (with GVxx) Yes (with GVxx)
Programming and LAN Remote
Assistance Yes (with LAN) Yes (with LAN) Yes (with LAN) Yes (with LAN) Yes (with LAN) Yes (with LAN)
Programming and PSTN Remote
Assistance Yes Yes Yes Yes Yes Yes
Programming and GSM Remote
Assistance Yes (with GSM) Yes (with GSM) Yes (with GSM) Yes (with GSM) Yes (with GSM) Yes (with GSM)
RTC + buffer battery No No No No Yes Yes
Note 1: The control unit manages one 001SEXP8 control unit input expansion module and one 001SMR8ICI bus input expansion module, or two 001SMR8ICI bus
input expansion modules.
Note 2: The control unit manages one 001SEXP8 control unit input expansion module and four 001SMR8ICI bus input expansion modules, or five 001SMR8ICI bus
input expansion modules.
Note 3: The control unit manages one 001SEXP8 control unit input expansion module and 14 001SMR8ICI bus input expansion modules, or 15 001SMR8ICI bus input
expansion modules.
Download and install the updated SWLINK and SWUPDATER
software.
Start SWLINK and click on
Control unit->Subtype->Update
rmware
: the SWFWUPDATER programme will start automatically.
Choose the control unit to update and the proper fi le to launch
to complete the procedure.
Then continue with the control unit's FW updating instructions that
follow, in the relative User's Manual .
WARNING! In the SWFWUPDATER and SWLINK software, the control
units with expanded inputs and outputs are called CP4044E,
CP4092E and CP8192E.
PROCEDURE
Page
3
- Installers manual code:
319V43E
319V43E ver.
1.0
1.0 - 05/2012 © CAME Cancelli Automatici S.p.A. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.A. to notify said changes.
ENGLISH
SW1
=ON
=OFF
ADDRES. CP4044E CP4092E CP8192E
SW1
=ON
=OFF
ADDRES. CP4044E CP4092E CP8192E
ON
1
0 not valid not valid not valid
ON
1
8Inputs
65..72
ON
1
1{see Note 1 Inputs
5..12
Inputs
5..12
Inputs
9..16
ON
1
9Inputs
73..80
ON
1
2Inputs
13..20
Inputs
13..20
Inputs
17..24
ON
1
10 Inputs
81..88
ON
1
3Inputs
21..28
Inputs
25..32
ON
1
11 Inputs
89..96
ON
1
4Inputs
29..36
Inputs
33..40
ON
1
12 Inputs
97..104
ON
1
5Inputs
37..44
Inputs
41..48
ON
1
13 Inputs
105..112
ON
1
6Inputs
49..56
ON
1
14 Inputs
113..120
ON
1
7Inputs
57..64
ON
1
15 Inputs
121..128
Note 1: Address 1 is only good when the 001SEXP8 control unit input expansion module is replaced with the 001SMR8ICI bus input expansion module.
ADDRESSING
8.2 MR8ICI (8 input bus expansion)
ADDRESSING
SW1
=ON
=OFF
ADDRES. CP4044E CP4092E CP8192E
SW1
=ON
=OFF
ADDRES. CP4044E CP4092E CP8192E
ON
1
0 not valid not valid not valid
ON
1
8Outputs
65..72
ON
1
1Outputs
5..12
Outputs
5..12
Outputs
9..16
ON
1
9Outputs
73..80
ON
1
2Outputs
13..20
Outputs
13..20
Outputs
17..24
ON
1
10 Outputs
81..88
ON
1
3Outputs
21..28
Outputs
25..32
ON
1
11 Outputs
89..96
ON
1
4Outputs
29..36
Outputs
33..40
ON
1
12 Outputs
97..104
ON
1
5Outputs
37..44
Outputs
41..48
ON
1
13 Outputs
105..112
ON
1
6Outputs
49..56
ON
1
14 Outputs
113..120
ON
1
7Outputs
57..64
ON
1
15 Outputs
121..128
The di erences in characteristics and procedure (managed by SWLINK or by the keypads after the Firmware is updated to the
mentioned versions) only concern 3 paragraphs of the 319V43 manual and are summarised below.
8.3 MR8O4R (8 output expansion)
Page
4
- Installers manual code:
319V43E
319V43E ver.
1.0
1.0 - 05/2012 © CAME Cancelli Automatici S.p.A. - The data and information in this manual may be changed at any time and without obligation on the part of Came Cancelli Automatici S.p.A. to notify said changes.
ENGLISH
STEP 1: Enabling input expansion in control unit
1. Enter user code (if less than 6 digits confirm with
*
).
2. Enter technical code to access technical menu.
3. With
select SYSTEM and press
*
.
4. With
select MODIFY SYSTEM and press
*
.
5. With
select INPUT MODULES .
6. Press
1
to enable expansion by adding the # sign on position 1 (#
= enabled, - disabled), and then press
.
7. With
+ -
select INSTALL. MODULE EXP8 .
8. press
#
to save, exit and return to previous menus
08:23 16/05/10
ENTER CODE 123456
STAND BY FOR COMM.
*=USER MENU 222222
SYSTEM 02
MODIFY
SYSTEM
*
INPUT MODULES
------------------
*
INPUT MODULES
#-----------------
#
1
ACQUIRING INPUT EXPANSION MODULES IN CONTROL UNIT
The local input expansion module has 1 as permanent address and the control units are not enabled to expand by factory default.
To enable the control unit to expand inputs, do the following:
ACQUIRING INPUT EXPANSION MODULES ON BUS
The system cannot have bus input expansion modules with the same addresses.
All expansions are made with address 2 and the control units do not have any enabled, factory-default expansions.
To enable the control unit to expand, do the following:
STEP 1: Address the expansion
1. Set the address on the expansion that you want to assign using the
four micro-switches (example 2:
ON
1
).
STEP 2: Enabling input expansion on bus
1. Enter user code (if less than 6 digits confirm with
*
).
2. Enter technical code to access technical menu.
3. With
select SYSTEM and press
*
.
4. With
select MODIFY SYSTEM and press
*
.
5. With
select INPUT MODULES .
6. Press the numerical key related to the expansion address you wish
to enable and then add
#
(# = enabled, - disabled).
7. If fitting to the system a bus input expansion module with address
1 to the system (which excludes installing the EXP8 into the control
unit), once the various input modules are enabled, press
.
8. With
+ -
select MODULE INSTALL. MR8ICI
.
9. Press
#
to save, exit and return to previsou menus
10. The module's communication on bus LED starts flashing.
08:23 16/05/10
ENTER CODE 123456
STAND BY FOR COMM.
*=USER MENU 222222
SYSTEM 02
MODIFY
SYSTEM
*
INPUT MODULES
------------------
*
INPUT MODULES
-#----------------
#
2
10.4 Addressing and learning of peripherals
/