ViziT EXIT 300M Operating instructions

Type
Operating instructions
EXIT 300
24 .
M Button
EXIT 300M
PARTS LIST
SAFETY INSTRUCTIONS
DO NOT expose the device to voltages above 24VDC.
Button with LED ring illumination for doorphone / video doorphone (the button hereinafter) is intended for
.
The button does not contain voltage above
Do not make any connections or repair when the power is on
Take care not to spill any liquids or chemically active substances on the product. Switch the power off before cleaning the
product. Clean by wiping with dry soft cloth. Do not use any liquid cleaners, aerosol cleaners or abrasive agents
.
.
VDC
OPERATING INSTRUCTION
use
with an electromagnetic lock to ensure lock release from inside of the building
www. 5EXIT 300M Button Operating Instruction (revision 12)vizit-group.com 1 2/201 -
(1)
(2) Illuminated ring
(3) Metal button
(4) Connecting wires
Metal housing
1
2
Destination
Wire colour
NC contact wires (NC contact provides
lock release in case of the Control Unit failure)
White
Green
NO contact wires (NO contact commands
lock release to the Control Unit)
Red
Supply voltage for LEDs of ring illumination
Black
4
3
Front view Back view
EXIT 300M button appearance, destination of wires and schematic diagram
Blue
Red
Green
White
Black
Blue
Operating Instruction
x1
x1
EXIT 300M
button
Fasteners
Screw 4 40
x2 x2
Gag
x 4
Anchor 4- 6х 0
INSTALLATION AND CONNECTION
SPECIFICATIONS
The button is mounted on a wall near the entrance door, inside the entrance doorway.
Connection of button to the doorstation / control unit and electromagnetic lock is made through 5 wires of
different colour. Wiring diagrams on connection of to various doorstations / control units and
electromagnetic locks are given in operating instructions on corresponding doorstations / control units.
Strikes, no less than
Contacts: NO, NC
Max. switchable current
Operating voltage
Dimensions (W)x(H)x(D)
Weight
Ambient temperature range to
Relative humidity of air up to at
EXIT 300M
EXIT 300M VIZIT
WARNING It is not allowed to use the button, if the door lock is not provided with degaussing circuitry.
M
A
VDC
mm
kg
OPERATING CONDITIONS
-10 +
93% +
,
!
EXIT 300 300000
1
24
75 х 47 х 22
0.1
°C 50°C
25°C
For qualified installation, wiring and servicing refer to technical and commercial partners of VIZIT TM.
The list of companies is given on VIZIT.EU ( .http://vizit.eu/eurounion/)
www. 5EXIT 300M Button Operating Instruction (revision 12)vizit-group.com 2 2/201 -
- Drill 2 holes (1) with diameter 6 mm and depth 40 mm.
- Drive anchors (2) into the holes.
- Drill a hole for wires ( ) with diameter 5 mm3.
60 mm
3
1
2
-
х0 ()
().
Attach the EXIT 300M button to the wall and
fasten two screws 4 4 4 in the anchors.
- Drive in gags 5
Note. Anchors and screws are supplied.
- Strip the ends of connecting wires that
will go to the , and
solder the ends to the button’s wires
following the diagrams given in the
section
.
Put tightly over each soldered
connection a PVC tube or a heat-shrink
tube around 10 mm long (3).
PVC tubes and heat shrink tubes are
not supplied
-
EXAMPLES OF WIRING DIAGRAMS
doorstation / control unit
on corresponding doorstation / control unit
EXIT 300M button mounting on a wall
4
5
3
  • Page 1 1
  • Page 2 2

ViziT EXIT 300M Operating instructions

Type
Operating instructions

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI