Focal Point Amica 2x2 FAML-22 Installation guide

Type
Installation guide

This manual is also suitable for

make electrical connections
amica
FAML 2x2 | 2x4
5x4 6x2
4
2x4 3x4
1
focal point
key
Luminaires must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, diconnect electrical supply before installation or servicing.
7 8 9
power off
power on
IS0509 REV. B 2015 ©Focal Point, LLC 4201 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 2
drywall frame kit
specify “DF” Drywall Frame Kit for drywall
ceiling conditions.
Use tie–wire or screws
to secure frame kit.
cut out dimensions:
2': Min: 24.25"
Max: 24.563"
grid
for lay–in grid, specify G1, G2 or G3.
g1
15/16"
g2
9/16"
g3
slot 9/16"
SLOT TEE (G3)
drywall frame kit
specify “DF” Drywall Frame Kit for drywall
ceiling conditions.
Use tie–wire or screws
to secure frame kit.
cut out dimensions:
2': Min: 24.25"
Max: 24.563"
grid
for lay–in grid, specify G1, G2 or G3.
g1
15/16"
g2
9/16"
g3
slot 9/16"
FLAT TEE (G1, G2)
attention
AVOID ALL CONTACT WITH LED SURFACE, LEDs ARE EASILY DAMAGED!
AIR RETURN (AR)
1
Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls
and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC
is prohibited.
IS0509 REV. B 2015 ©Focal Point, LLC 4201 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 2
serVice
remoVe DriVer coVer
11
32
0-10V DIMMING & NON-DIMMING STANDARD WIRING
WHITE
(NEUTRAL)
BLACK
(LINE)
GREEN
PURPLE (+)
GRAY (-)
PURPLE
GRAY
**OPTIONAL**
(individually capped at factory
for non-dimming applications)
(if capped together, xture will
automaticaly dim to lowest setting)
0-10V DIMMER
*OUTPUT WIRE VARIATIONS:
RED (+), BLUE (-)
RED (+), BLACK (-)
BLACK (+), YELLOW (-)
(-)*
(+)*
LED
reference DriVer manUfactUrer’s spec sHeets for DriVer specific wirinG DiaGrams.
emerGency lUminaires wireD accorDinG to Battery MANUFACTURER’s instrUctions.
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
1 11113112
air retUrn installation
make electrical connections
  • Page 1 1
  • Page 2 2

Focal Point Amica 2x2 FAML-22 Installation guide

Type
Installation guide
This manual is also suitable for

Ask a question and I''ll find the answer in the document