  • Hello! I'm a chat assistant, and I've reviewed the installation instructions for the Focal Point FSM2PR LED Perimeter lighting fixture. This document covers various installation methods, includes adjustable housings, sliding sleeves, and corners. I'm ready to help answer any questions you have about installing this device.
  • What should be done before starting the installation?
    Who is responsible for reinforcing the walls or ceilings?
    What is the recommended mounting height for emergency lighting?
1 of 10
IS0722 REV. H
©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
Luminaires must be installed by a qualified
electrician (check with local and national
codes for proper installation).
To prevent electrical shock, disconnect
electrical supply before installation or
servicing.
Contractor is responsible for adequately
reinforcing walls and/or ceilings to support
fixture weight.
Focal Point, LLC accepts no responsibility
for inadequately reinforced walls and/or
ceilings.
The information contained in this drawing
is the sole property of Focal Point, LLC. Any
reproduction in part or whole without the
written permission of Focal Point, LLC is
prohibited.
POWER OFF
POWER ON
ATTENTION
SEE ADDITIONAL
INSTRUCTIONS
BEFORE YOU BEGIN COMPONENT KEY
INSTRUCTION KEY
HOUSING TYPES  ' SHOWN
1
3
5
11
17
16
4
9
10 12
8
2
7
6
13
1 Housing
2 Adjustable housing
3 Sliding sleeve (ss)
(shipped installed. SSB indicates
a sliding sleeve at both ends)
4 Finish plate
5 J-rail
6 Z-rail
7 Housinf rail kit
8 Tie-wire/grid bracket
9 Tie-wire bracket
10 Joiner pin
11 Joiner bracket assembly
12 Corner j-rail
13 Lens end piece
14 Lens tool
15 Hardware bag
16 Outside corner
17 Inside corner
BY OTHERS:
Grid ceiling -
15/16" or 9/16" flat tee main
runner required
for finish edge.
INDIVIDUAL MAY INCLUDE SLIDING SLEEVES START SHOWN WITH SLIDING SLEEVE
INTERMEDIATE END SHOWN WITH SLIDING SLEEVE
PARTS LIST
ADJUSTABLE HOUSING
14
15
Seem® 2 LED Perimeter
FSM2PR | GRID/TRIMLESS DRYWALL
2 of 10
IS0722 REV. H ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
1.50"
4.68" 4.88"
2.64"
3.15" - 3.5"
0.5" - 0.88"
0.31"
1.50"
4.5" 4.88"
2.64"
3.15" - 3.5"
0.5" - 0.88"
1.50"
4.5" 4.88"
0.5" - 0.88"
WALL/CEILING PREPARATION
1.50"
7.00" 7.38"
2.64"
3.15" - 3.5"
0.5" - 0.88"
CEILING LINE
2.50"
1.50"
8.5" 8.88"
2.64"
3.15" - 3.5"
0.5" - 0.88"
CEILING LINE
4.00"
Flush Lens Lay-In Grid Flush Lens Slot Tee/Tegular
Regressed 2.5" Grid Regressed 4" Grid
GRID CEILING  /" OR /" FLAT TEE MAIN
RUNNER REQUIRED FOR FINISH EDGE.
GRID CEILING  /" OR /" FLAT TEE MAIN
RUNNER REQUIRED FOR FINISH EDGE.
GRID CEILING  /" OR /" FLAT TEE MAIN
RUNNER REQUIRED FOR FINISH EDGE.
GRID CEILING  /" OR /" FLAT TEE MAIN
RUNNER REQUIRED FOR FINISH EDGE.
3 of 10
IS0722 REV. H ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
BASIC INSTALLATION
21 3
1.50"
7.00" 7.38"
2.64"
3.15" - 3.5"
0.5" - 0.88"
CEILING LINE
2.50"
1.50"
8.5" 8.88"
2.64"
3.15" - 3.5"
0.5" - 0.88"
CEILING LINE
4.00"
WALL/CEILING PREPARATION
Regressed 2.5" Trimless Drywall Regressed 4" Trimless Drywall
DRYWALL/HARD CEILING MOUNT BELOW HOUSING
DRYWALL/HARD CEILING MOUNT BELOW HOUSING
FOCAL POINT RECOMMENDS
STARTING WITH CORNER
INSTALLATION IF APPLICABLE
BASIC INSTALLATION, STEPS 
ADJUSTABLE HOUSING, PAGE 
SLIDING SLEEVES, PAGE 
CORNERS, PAGE 
SLIDING SLEEVE PAIRS SSB START
& END WITH A SLIDING SLEEVE
MOUNT JRAIL TO WALL
HARDWARE BY OTHERS START, INTERMEDIATE, & END UNITS ONLY START, INTERMEDIATE, & END UNITS ONLY
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
GRAZER LENS DISTRIBUTION DIRECTION
ASYMMETRIC ROOM FILL LENS
DISTRIBUTION DIRECTION
OPTIONAL
REMOVE END CAP FLANGE ON
START AND/OR END OF RUN
HOUSINGS WHEN FLUSH
INSTALLATION AGAINST
FINISHED WALL
IS DESIRED
4 of 10
IS0722 REV. H ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
9
7
5
11
6 8
10
GRID
LIFT HOUSING
INTO PLACE
ENGAGING
JRAIL AND
TEE GRID
LEVEL HOUISNG
AND SECURE
TO STRUCTURE
ABOVE WITH
TIEWIRE
FOR ALL
HOUSING TYPES
INDIVIDUAL HOUSING SKIP TO STEP 
MAKE ELECTRICAL CONNECTIONS MAKE ELECTRICAL CONNECTIONS
13
DRYWALL/HARD CEILING
DRYWALL/HARD CEILING MOUNTS BELOW
HOUSING STRUCTURE BY OTHERS
11
12
REFERENCE INSTRUCTIONS ON INCLUDED
TOOL FOR LENS INSTALLATION
SEE BATTERY MANUFACTURER
INSTRUCTIONS
EMERGENCY MAXIMUM MOUNTING HEIGHT
FROM FLOOR TO SURFACE OF LENS:
.'
EMERGENCY
REPEAT STEPS   
FOR EACH HOUSING SECTION
5
DRYWALL/HARD CEILING
USE CAUTION:
DAMAGE MAY
RESULT I F
HOUSING
IMPACTS WALL
4
GRID
BEND TEE TABS
5 of 10
IS0722 REV. H ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
6
3
111
2
411
5
ADJUSTABLE HOUSING
97 11
8
1210 11
11
IF HOUSING LENGTH IS CORRECT SKIP TO STEP 
ADJUST HOUSING TO
DETERMINED LENGTH
REMOVE KNOCKOUTS FOR
ELECTRICAL ACCESS IF NECESSARY
CUT HOUSING RAILS TO DETERMINED LENGTH
USE PROVIDED RAIL KIT WHEN
LENGTHENING HOUSING CUT JRAIL TO DETERMINED LENGTH
CUT ZRAIL TO DETERMINED LENGTH
FOLLOW BASIC INSTALLATION
INSTRUCTIONS  ON PAGES 
6 of 10
IS0722 REV. H ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
1513 11
14
SLIDING SLEEVES
CUT LENS TO DETERMINED LENGTH MAKE ELECTRICAL CONNECTIONS
31 11
2
64 11
5
REMOVE KNOCKOUTS FOR
ELECTRICAL ACCESS IF NECESSARY
MAKE ELECTRICAL CONNECTIONS
CUT FINISH PLATE TO
DETERMINED LENGTH
SINGLE SLIDING SLEEVE SS:
EXAMPLE:
' RUN LENGTH  ' HOUSING = " SLIDING SLEEVE
SLIDING SLEEVE DOES NOT INTEGRATE WITH ADJUSTABLE HOUSING
SLIDING SLEEVE PAIR SSB:
EXAMPLE:
' RUN LENGTH  ' HOUSING /  = " SLIDING SLEEVE ON EACH END
12" 6" 6"
MAX LENGTH " PER SLEEVE
7 of 10
IS0722 REV. H ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
711
8
CORNERS
1
4
2
5
3
7 8
LIFT HOUSING INTO
PLACE ENGAGING JRAIL
SECURE TO STRUCTURE ABOVE
WITH TIEWIRE
6
FOLLOW BASIC INSTALLATION
INSTRUCTIONS  ON PAGES 
MAKE ELECTRICAL CONNECTIONS
8 of 10
IS0722 REV. H ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
DRIVER SERVICE
2
START, INTERMEDIATE, & END UNITS ONLY
1
START, INTERMEDIATE, & END UNITS ONLY
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
GRID ONLY
WATTSTOPPER
8
56
DA– DA+
79
SEE CONTROLS MANUFACTURER
FOR WIRING INSTRUCTIONS
1 32
4
CEILING
CUTOUT
"
RECOMMENDED
Ø ."
9 of 10
IS0722 REV. H ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
1 3
6
2
5
4
GRID ONLY
CEILING
CUTOUT
"
RECOMMENDED
Ø ."
WAVELINX
56
ENLIGHTED
1 32
4
CEILING
CUTOUT
"
RECOMMENDED
Ø .
10 of 10
IS0722 REV. H ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
GRID ONLY
12 3
45
1
CAT CABLE
CONNECT CAT CABLE
CONNECT
CAT CABLE
1
CONNECT
CAT CABLE
WAVELINX
8
7a 7b 7c 7d
ACUITY nLIGHT
WATTSTOPPER HUBBELL NX
/