1 Card view
Figure 1 NSQ1SUPB0 MPU
2 Specifications
Figure 2 Front panel of the NSQ1SUPB0
(1) Console port (CONSOLE) (2) 10/100/1000BASE-T copper combo port GE3
(3) Mana
g
ement Ethernet port LED (4) Fan status LED
(5) Card status LED (6) MPU status LED (ACTIVE)
(7) Reset button
Table 1 Card specifications
Item S
p
ecification
Dimensions (H × W × D) 40 × 399 × 352 mm (1.57 × 15.71 × 13.86 in)
Power consumption 45 W to 50 W
Weight 2.97 kg (6.55 lb)
Hot swapping Supported
Connector type RJ-45
Interfaces
1 console port
One 10/100/1000BASE-T Ethernet port
Ambient temperature
Operating: 0°C to 45°C (32°F to 113°F)
Storage: –40°C to +70°C (–40°F to +158°F)
3
4 51 2 6 7
Manual Version: 6PW102-20170414 BOM: 3123A0R4
ii
Item S
p
ecification
Ambient humidity
Operating: 10%RH to 95%RH, noncondensing
Storage: 5%RH to 95%RH, noncondensing
Compatible device model and slot
M9006 multi-service security gateway (Slot 0 and Slot 1)
M9010 multi-service security gateway (Slot 4 and Slot 5)
M9014 multi-service security gateway (Slot 6 and Slot 7)
Table 2 Console port specifications
Item S
p
ecification
Connector RJ-45
Interface standard RS-232
Transmission baud rate 9600 bps (default) to 115200 bps
Transmission medium Asynchronous serial cable
Transmission distance 15 m (49.21 ft)
Services
Provides connection to an ASCII terminal.
Provides connection to the serial port of a local or remote (through a
pair of modems) PC running terminal emulation program.
Supports command line interface (CLI)
Table 3 10/100/1000BASE-T copper port specifications
Item S
p
ecification
Connector RJ-45
Interface standard 802.3, 802.3u, and 802.3ab
Interface type MDI/MDIX autosensing
Supported cable Category-5 (or above) twisted pair cable
Transmission distance 100 m (328.08 ft)
Port transmission rate
10 Mbps, half/full duplex
100 Mbps, half/full duplex
1000 Mbps, full duplex
3 LEDs
Table 4 Ethernet port LED description
LIN
K
ACT Descri
p
tion
On Flashing
A link is present, and the management Ethernet port is receiving or
sending data.
On Off A link is present.
Off Off No link is present.
Manual Version: 6PW102-20170414 BOM: 3123A0R4
iii
Table 5 Ethernet port LED description
O
K
FAIL Descri
p
tion
On Off The fan tray is operating correctly.
Off On A fan problem is present or the fan tray is not in position.
Off Off The gateway is not powered on.
Table 6 MPU RUN and ALM LED description
RUN ALM Descri
p
tion
Flashing Off The card is operating correctly.
Flashing On
The card is loading software.
If the LED flashes continuously, the software version of the device does
not match that of the card.
On On The card is booting or faulty.
On Off The MPU is starting up.
Off Off The card is not in position.
NOTE:
A quick flashing RUN LED indicates that the card is starting up rather than operating properly.
It is normal that the ALM LED for an LPU li
g
hts for a period of time at the initial phase of the system
startup.
Table 7 MPU ACTIVE LED description
LED status Descri
p
tion
On The MPU is active.
Off
The MPU is in standby status.
The MPU is faulty. Examine the card LED for an MPU problem.
4 Installing and removing the NSQ1SUPB0 MPU
CAUTION:
Wear a well-grounded ESD-preventive wrist before you install or remove the card.
Do not touch the surface-mounted components directly with your hands when you install or remove
the card.
4.1
Installing the NSQ1SUPB0
1. Face the front panel of the device.
2. Identify the slot to install the card, and remove the filler panel from the slot.
This manual uses slot 1 as an example.
Manual Version: 6PW102-20170414 BOM: 3123A0R4
iv
3.
Place the card horizontally with the surface-mounted components facing upward. Pull outward the
ejector levers and gently push the card in along the slot guide rails until the card is in close contact
with the backplane. (See callout 1 in Figure 3 .)
4. Push the ejector levers inward. (See callout 2 in Figure 3 .)
5. Tighten the captive screws with a Phillips screwdriver to secure the card in the slot. (See callout 3
in Figure 3 .)
Figure 3 Installing the
NSQ1SUPB0
(1) Gently push the card in along the slot guide rails until the card is in close contact with the backplane.
(2) Push the ejector levers inward.
(3) Ti
g
hten the captive screws with a Phillips screwdriver, and installation is finished.
4.2
Removing the NSQ1SUPB0
1. Use a Phillips screwdriver to loosen the captive screws at both sides of the card until all pressure
is released.
2. Pull the ejector levers at both sides of the card outward, and pull the card along the guide rails until
it completely comes out of the backplane.
3. Place the card on an anti-static workbench with the surface-mounted components up, or put it in an
anti-static bag.
If no new card is to be installed, install a filler panel to prevent dust and ensure good ventilation in
the device.
5 Software upgrade
For more information, see the release notes.
6 Obtaining documentation
To access the most up-to-date H3C product documentation on the H3C website at www.h3c.com.hk:
1. Go to http://www.h3c.com.hk/Technical_Documents.
2. Choose the desired product category and model.
Copyright © 2017 New H3C Technologies Co., Ltd.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

H3C SecPath M9000 NSQ1SUPB0 MPU User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI