Manual Version: 6PW104-20170414 BOM: 3123A0R3
ii
Item S
ecification
Ambient humidity
Operating: 10%RH to 95%RH, noncondensing
Storage: 5%RH to 95%RH, noncondensing
Compatible device model and slot
M9006 gateway (slot 6 to slot 9)
T9006 IPS (slot 6 to slot 9)
3 LEDs
The NSQ1FAB04B0 provides LEDs to show the operating status of the switching fabric module.
Table 2 LED description
RUN LED ALM LED Descri
tion
Flashing (0.5 Hz) Off The switching fabric module is operating properly.
Off On The switching fabric module is faulty.
Flashing (0.5 Hz) On
The temperature of the switching fabric module has exceeded the
upper or lower limit.
Off Off The switching fabric module has not started.
On Off The switching fabric module is up.
4 Installing and removing the NSQ1FAB04B0
CAUTION:
• Wear a well-grounded ESD-preventive wrist before you install or remove the switching fabric
module.
• Do not touch the surface-mounted components directly with your hands when you install or remove
the switching fabric module.
At least one switching fabric module is required. Install in to either Slot 6 or Slot 7. You can install a
maximum of 4 switching fabric modules on the device.
4.1
Installing the NSQ1FAB04B0
1. Face the rear panel of the device.
2. Identify the slot to install the switching fabric module, and remove the filler panel from the slot.
This manual uses slot 7 as an example.
3. Place the switching fabric module vertically with the surface-mounted components facing left. Pull
outward the ejector levers and gently push the switching fabric module in along the slot guide rails
until the switching fabric module is in close contact with the backplane. (See callout 1 in Figure 3 .)
4. Push the ejector levers inward. (See callout 2 in Figure 3 .)
5. Tighten the captive screws with a Phillips screwdriver to secure the switching fabric module in the
slot. (See callout 3 in Figure 3 .)