H3C LSQM1EPSB0 User manual

Type
User manual
Manual version: APW102-20191215 BOM: 3123A1VH
i
H3C LSQM1EPSB0 EPS endpoint security module
1 Identifier
The module identifier LSQM1EPSB0 is in the upper right corner of the front panel.
2 About the module
The LSQM1EPSB0 is an EPS endpoint security module built with server components required for
EPS solutions. It can provide converged solutions to manage endpoint access and authentication for
small and medium-sized campus networks, eliminating the need for installing a physical server.
Figure 1 LSQM1EPSB0 front panel
(1) USB ports (3 in total) (2) VGA connector
(3) Management Ethernet port (4) Management Ethernet port LED (LINK/ACT)
(5) Console port (CONSOLE) (6) Shutdown LED and button (SHUTDOWN)
(7) Ejector lever (8) Captive screw
3 Specifications
Table 1 Module specifications
Item Specifications
Hard disk 480GB SSD
Memory
Two memory slots
Standard configuration: 64 GB (two 32GB memory bars)
Dimensions (H × W × D) 40 × 399 × 355 mm (1.57 × 15.71 × 13.98 in)
Weight 3.40 kg (7.50 lb)
Power consumption 102 to 124 W
Hot swapping Not supported
Ports
3 × USB2.0 ports (used by technical support for debugging only)
1 × VGA connector
1 × 10/100/1000BASE-T management Ethernet port
1 × console port (used by technical support for debugging only)
Ambient temperature
Operating: 0°C to 45°C (32°F to 113°F)
Storage: –40°C to +70°C (–40°F to +158°F)
Manual version: APW102-20191215 BOM: 3123A1VH
ii
Item Specifications
Ambient humidity
Operating: 5% RH to 95% RH, noncondensing
Storage: 5% RH to 95% RH, noncondensing
NOTE:
To verify the compatibility of the card with the software release you are using, see the release
notes.
For information about transceiver modules and cables available for the card, see the cards and
transceiver modules compatibility matrixes for the device.
Table 2 10/100/1000BASE-T management Ethernet port specifications
Item Specification
Standard 802.3, 802.3u, and 802.3ab
Auto-MDI/MDIX Supported
Cable Category 5 or above twisted pair cable
Transmission distance 100 m (328.08 ft)
Rate and duplex mode 10/100/1000 Mbps, full-duplex mode
4 LEDs
Table 3 LED description
LED Status Description
10/100/1000BASE-T
management Ethernet port
LED (LINK/ACT)
Steady green A 10/100/1000M link is present on the port.
Flashing green
The port is sending or receiving data at 10/100/1000
Mbps.
Off No link is present on the port.
Shutdown LED
(SHUTDOWN)
Steady green The module is operating.
Flashing green
The module is being shut down. You can shut down the
module only after the LED turns off.
Off The module is not operating.
5 Installing and removing the module
CAUTION:
Wear a reliably grounded ESD wrist strap or ESD gloves when installing or removing the module.
Do not touch the components on the module.
The module can be installed in a horizontal or vertical slot. When installing the module in a horizontal
slot, make sure its component side faces up. When installing the module in a vertical slot, make sure
its component side faces left.
The installation and removal procedures are the same for horizontal and vertical slots. The following
procedures install and remove the module in a horizontal slot.
Manual version: APW102-20191215 BOM: 3123A1VH
iii
5.1
Installing the module
1. Face the front panel of the device. Remove the filler panel from the target slot.
This example installs the module in slot 2 on an S7506E switch.
2. Place the module on a workbench with its component side facing up. Open the ejector levers of
the module.
3. Gently push the module into the slot along the guide rails.
4. Close the ejector levers and make sure the module makes close contact with the backplane.
5. Use a Phillips screwdriver to fasten the captive screws on the module.
Figure 2 Installing the module
5.2
Removing the module
IMPORTANT:
Before removing the module, press the shutdown button on the module for a minimum of 2 seconds
until the shutdown LED flashes green. You can remove the module only after the shutdown LED
turns off.
To remove the module:
1. Use a Phillips screwdriver to loosen the captive screws on the module until all pressure is
released.
2. Simultaneously open the ejector levers of the module to disengage the module connector from
the backplane. Then pull the module gently out of the slot along the guide rails.
3. Place the removed module on an anti-static workbench or put it in an anti-static bag, with the
component side facing up.
4. If you are not to install a new module, install a filler panel in the slot to prevent dust and ensure
good ventilation in the device.
1
2
3
Manual version: APW102-20191215 BOM: 3123A1VH
iv
6 Software upgrade
For information about upgrading the software, see the release notes for the module.
Copyright © 2019 New H3C Technologies Co., Ltd.
The information in this document is subject to change without notice.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

H3C LSQM1EPSB0 User manual

Type
User manual

Ask a question and I''ll find the answer in the document