  • Hello! I am an AI chatbot trained to assist you with the CTC Union EOC-101L-P User manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Description
EOC-101-P are a compact pair of Ethernet LAN
extenders, over traditional coaxial cable infrastructure,
that also supports remote power feeding and power
splitting along with high speed Ethernet transmission.
Power feeding eliminates the need for any extra power
line provisioning at the remote device.
The EOC-101-P is an excellent solution for remotely
connected IP cameras, WiFi access points, digital signage
and even low port count Ethernet switches. By eliminating
the need for expensive and sometimes prohibitive power
wiring at the remote, significant savings can be realized
while installation is made less complex. Just connect the
coaxial cable between devices, attach the LAN cables and
apply external power at the local side only.
Features
Avoid the additional expense of electrical contractors
Long transmission distance, up to 1.5Km
Remote power feeding and power splitting
Simultaneous transmission of data and power over coax
High transmission bandwidth supports 1080p/30fps IP-Cam
Supplies up to 12W (12V@1A) to remote device @1Km
Ethernet compliant with IEEE802.3 and 802.3u
Supports Auto MDI/MDI-X
Wall mounting brackets provided
Application include remote powering IP camera, Access
Point, embedded computer (sign board, digital signage)
Power, Ethernet link and coaxial link LED indicators
User Guide
Ethernet Extender with Remote Power Feeding
EOC-101-P
includes EOC-101L-P (local unit) and
EOC-101R-P (remote unit)
Notes:
Specifications
Standards IEEE802.3, IEEE802.3u, IEEE802.3x
Mode 10/100Base-T (auto-negotiation)
Connectors RJ-45x1 (LAN), F-Typex1 (Coaxial)
Power Adapter AC100~240 input, DC63V, 800mA output
Consumption 33W (max)
Remote output 12VDC x 2, 1A/12W total, @1000 meter
Performance
Distance (meters) 300 500 700 1000 1200 1500
Up stream (mbps) 76 69 55 41 25 5
Down stream (mbps) 90 90 90 82 69 55
Remote power (W) 18 16 15 12 9.5 7.5
Physical
Dimensions 95mm x 124mm x 30mm WxLxH
Weight 360 grams net (EOC-101L)
385 grams net (EOC-101R)
Environment
Operation 0 ~ 50°C (32~122°F), 20 ~ 95% RH
Storage -20 ~ 80°C (-4~176°F), < 95% RH
Compliance
EMI/EMC CE / FCC Part 15 class B
V1.0
Installation
EOC-101-P must be used in local/remote pairs. Place the
EOC-101L-P at the local location where AC power is available.
Place the EOC-101R-P unit at the remote location or where no
AC power is available. Connect the two units via coaxial cable
(RG-6 recommended) terminated with F-type connectors. At the
remote location, connect the Ethernet device to the LAN port of
EOC-101R-P unit and connect the device's power to one of the
EOC-101R-P's 12V DC Out connectors. The load must not
exceed 12watts. At the local site, connect the LAN port of the
EOC-101L-P to an uplink Ethernet switch. WITHOUT AC POWER
CONNECTED, connect the power adapter to the DC In connector.
Make sure all connections are secure first, then lastly plug the AC
adapter to mains AC power source (100-240VAC).
Application
LED Indicators
LED indicators are used to provide a quick indication of the status of
power, LAN link and Coaxial connection. The following table provides the
definition of each LED and its state.
LED
State
Indication
PWR
OFF
Power is OFF
ON
Power is applied
LAN
OFF
ON
LAN Link established
FLASH
LAN Link & Traffic
COAX
OFF
No connection
BLINK
Normal connection
FLASH
Link training or
traffic
Model Summary
EOC-101-P
Remote Power Feeding Ethernet Extender over Coax
Technical Contact
CTC Union Technologies Co., Ltd.
Far Eastern Vienna Technology Center
(Neihu Technology Park)
8F, No. 60 Zhouzi St.
Neihu District, Taipei, 114 Taiwan
Phone: +886-2-2659-1021
FAX: +886-2-2799-1355
Version 1.0 Release, January 23, 2014
This document is the current official release manual. Please check CTC Union's website
for any updated manual or contact us by E-mail at [email protected]. Please address any
comments for improving this manual or to point out omissions or errors to
[email protected]. For technical support for this product or other CTC Union
products, contact our support staff at [email protected]. Thank you.
Warning
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio
communications. However, there is no guarantee that
interference will not occur in a particular installation.
This device complies with part 15 of FCC rules. Operation is
subject to the following two conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Change or modifications that are not expressly approved by
the manufacturer could void the user’s authority to operate the
equipment.
CISPR PUB.22 Class B COMPLIANCE:
This device complies with EMC directive of the European
Community and meets or exceeds the following technical
standard. EN55022 -Limits and Methods of Measurement of
Radio Interference Characteristics of Information Technology
Equipment. This device complies with CISPR Class B.
CE NOTICE
Marking by the symbol CE indicates compliance of this equipment
to the EMC directive of the European Community. Such marking
is indicative that this equipment meets or exceeds the following
technical standards: EN55022:2010 Class B and EN61000-3-
2:2010, EN 610003-2:2006 +A1+A2 and EN61000-6-1:2007.
/