Mettler Toledo InPro 4010 User manual

Type
User manual

This manual is also suitable for

InPro 4010 pH electrode 11
© 03 / 18 Mettler-Toledo GmbH InPro 4010 pH electrode
Printed in Switzerland 52 000 522 C
en
1 Introduction ...................................................................12
2 Safetyinstructions ..........................................................12
3 Productdescription .........................................................12
4 Installation and commissioning .......................................12
5 Calibration and measurement ..........................................13
6 Maintenance ..................................................................13
7 Removalofdirtandresidue .............................................13
8 Environmental protection .................................................13
9 Guarantee ......................................................................13
Contents
InPro
4010
pH Electrode
Instruction Manual
InProisaregisteredtrademarkoftheMETTLERTOLEDO
GroupinSwitzerland,theUSA,theEuropeanUnionanda
furthervecountries.
en Instruction manual
12 InPro 4010 pH electrode
InPro 4010 pH electrode © 03 / 18 Mettler-Toledo GmbH
52 000 522 C Printed in Switzerland
1 Introduction
METTLER TOLEDO pH sensors Type InPro 4010
®
are low-maintenance measuring electrodes with
apolymerelectrolyteandbuilt-intemperaturesensor.
InPro4010sensorsaredesignedforthesimultaneous
measurement of pH value and temperature in industrial
wastewater.
Pleasereadtheseinstructionscarefullybeforeputting
thesensorintooperation,inordertoensurefaultless
function. InPro 4010 sensors are non-sterilizable/
non-autoclavable and unsuitable for measurements
atpHvalues<2,inmediacontainingchlorineorin
organic solutions.
2 Safetyinstructions
Thesensorisintendedonlyfortheusedescribedin
§1above.Thesensorconsistspartlyofglass.Ifthe
sensor is to be cleaned or calibrated using acid or
alkalinesolutions,safetygogglesandglovesshould
be worn. In addition, local and in-house-safety
regulations must be observed.
We recommend that the electrodes only be
put into operation in conjunction with original
products/accessories from METTLER TOLEDO. The
electrodes may be operated and serviced only by
personnelfamiliarwiththeequipmentinquestionand
whohavereadandunderstoodtheseinstructions.
3 Product description
The inscription on each electrode contains the
followinginformation:
METTLER TOLEDO Manufactureroftheelectrode
InPro
®
4010/xxx/yyy Typedesignation/xxx=shaft
lenghtinmm/yyy=temperature
sensor
combination pH Typeofelectrode
pH 2 12 pH measurement range
0…60°C(32140°F) Temperaturerangeforoperation
OrderNo.5200XXXX Ordernumber
4 Installation and commissioning
1. On unpacking, and again prior to installation,
checkthesensorformechanicaldamageofthe
glassmembraneandshaft.Reportanydamage
immediatelytoyourMETTLERTOLEDOsupplier.
2. Remove the watering cap and rinse the sensor
with deionized water. After rinsing, the sensor
shouldonlybedabbeddrywithatissue.Donot
rubtheglassmembrane,sincethiscanleadto
electrostatic charging and sluggish response
times.
en
InPro 4010pHelectrode 13
© 03 / 18 Mettler-Toledo GmbH InPro 4010 pH electrode
Printed in Switzerland 52 000 522 C
en
3.Checkthemembranechamberoftheelectrodefor
thepresenceofanyairbubblesandremovesame
bylightlyswingingthesensorinaverticalplane.
4. Pleaserefertotheinstructionmanualoftherelative
housinginordertoinstallthesensor.
5. Connect the sensor to the pH transmitter,
using a cable with VP (Vario Pin) connector.
Please refer to thewiring and terminal diagram
accompanyingthecable.
5 Calibration and measurement
InPro4010sensorsrequire 2-pointcalibration.The
sensoristhendippedinsuccessionintotwodifferent
buffersolutionswithgivenpHreferencevaluesandthe
transmittercalibratedtothesebuffervalues.Please
refertotheinstructionmanualofthetransmitterfor
details.
6 Maintenance
Thesensorwithpolymerelectrolytecannotberelled.
Thesensormustnotbestoreddry.Intheeventthat
the sensor dries out, it is necessary to recondition
it before use by immersion in FRISCOLYT™ (Order
No.51340053)foratleast24hours.InPro4010
sensors should be stored with tted watering cap
containingFRISCOLYT.Aftereachworkingcycle,the
sensortipandtheapertures(diaphragms)mustbe
thoroughlycleanedusingdeionizedwater.
7 Removal of dirt and residue
1. Sluggish response time. Theglass membrane
canbereactivatedusingaHFsolution(OrderNo.
51319053).Onlythatsectionofthesensortip
below the two (diaphragms) apertures may be
immersed in theHFsolution, and this duringa
periodofabout5minutes.Immediatelya f terwards,
rinse the sensor thoroughly and immerse in
FRISCOLYTforatleast12hours.
2. Insufcient sensitivity (slope). Check the
aperturesforcontaminationandrinsewithwarm
water. Check the VP connector for traces of
moisture.Ifnecessary,cleanwellusingdeionized
wateroralcohol,andafterwardsdrycarefully.
8 Environmental protection
Waste electrical products should not be
disposed of with household waste. Please
recyclewherefacilitiesexist.Checkwithyour
LocalAuthorityorretailerforrecyclingadvice.
9 Guarantee
Onmanufacturingdefects,12monthsafterdelivery.
56 InPro 4010 pH electrode
InPro 4010 pH electrode © 03 / 18 Mettler-Toledo GmbH
52 000 522 C Printed in Switzerland
zh
InPro 4010pHelectrode 57
© 03 / 18 Mettler-Toledo GmbH InPro 4010 pH electrode
Printed in Switzerland 52 000 522 C
zh
58 InPro 4010 pH electrode
InPro 4010 pH electrode © 03 / 18 Mettler-Toledo GmbH
52 000 522 C Printed in Switzerland
Notes
InPro 4010 pH electrode 59
© 03 / 18 Mettler-Toledo GmbH InPro 4010 pH electrode
Printed in Switzerland 52 000 522 C
Notes
Brazil Mettler-Toledo Ind. e Com. Ltda.
AvenidaTamboré,418–Tamboré,
BR-06460-000Barueri/SP,Brazil
Phone+551141667400
e-mail mtbr@mt.com
France Mettler-ToledoAnalyseIndustrielleS.A.S.
30,Bld.deDouaumont,FR-75017Paris,France
Phone+33147370600
e-mail mtpro-f@mt.com
Germany Mettler-ToledoGmbH
Prozeßanalytik,Ockerweg3,DE-35396Gießen
Phone+49641507-444
e-mail prozess@mt.com
Switzerland Mettler-Toledo(Schweiz)GmbH
ImLangacher,CH-8606Greifensee
Phone+41449444747
e-mailProSupport.ch@mt.com
United States METTLER TOLEDO
ProcessAnalytics
900MiddlesexTurnpike,Bld.8,Billerica,MA01821,USA
Phone+17813018800
Freephone+18003528763(onlyUSA)
e-mail mtprous@mt.com
FormoreaddressesofMETTLERTOLEDOMarketOrganizationspleasegoto:
www.mt.com/pro-MOs
Mettler-ToledoGmbH,ProcessAnalytics,ImHackacker15,CH-8902Urdorf
Phone+41447296211,Fax+41447296636
Subjecttotechnicalchanges
03/2018©METTLERTOLEDO.Allrightsreserved
PrintedinSwitzerland.52000522C
www.mt.com/pro
Addresses|Impressum
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60

Mettler Toledo InPro 4010 User manual

Type
User manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI