  • Hello! I'm your chat assistant and I've reviewed the installation instructions for the Focal Point Seem 1 Louver (models FSM1CS and FSM1CBS). This document provides details on individual and run configurations, electrical connections, and safe component handling. I'm ready to answer any questions you have about the installation process or the product itself.
  • Who should install the luminaires?
    What should be done before installation or servicing?
    What is the contractor responsible for?
1 of 2
IS0807 REV. A
©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
Seem® 1 Louver
Suspended | FSM1CS | FSM1CBS
Congurationsarerunspecic,
pleaseconsultfactorydrawings
beforebeginninginstallation.
Luminaires must be installed by a qualied
electrician (check with local and national
codes for proper installation).
To prevent electrical shock, disconnect
electrical supply before installation or
servicing.
Contractor is responsible for adequately
reinforcing walls and/or ceilings to support
xture weight.
Focal Point, LLC accepts no responsibility
for inadequately reinforced walls and/or
ceilings.
The information contained in this drawing
is the sole property of Focal Point, LLC.
Any reproduction in part or whole without
the written permission of Focal Point, LLC
is prohibited.
POWER OFF
POWER ON
ATTENTION
SEE ADDITIONAL
INSTRUCTIONS
BEFORE YOU BEGIN COMPONENT KEY
INSTRUCTION KEY
U - Individual
S - Start of run
I - Intermediate
E - End of run
FOCAL POINT SHIPPED INSTALLED
Joiner
(A46895-01)
Alignment Plate
(A46949-01)
Alignment Plate Screw
8-32 x 7/8"
(700366)
Joiner Screw
10-32 x 3/4"
(700365)
Product ID label
on reector
INDIVIDUAL INSTALLATIONS FOLLOW STEPS 1 & 2
21
Two cable grippers each for individual and
start, one for intermediate and end housings.
Follow Focal Point instructions for
Universal Suspension System assembly.
See IS0166
3
Flush Lens
Louver
Faceplate
IS0807 REV. A ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference 2 of 2
4
MAKE ELECTRICAL CONNECTION
5
7 8
11
6
DO NOT OVERTIGHTEN.
Note: Screw head may not seat to bracket. Seat screw rmly.
DRIVER SERVICE
Avoid all contact with LED surface,
LEDs are easily damaged!
Alignment Plate
Screw (700366) Joiner Screw
(700365)
EM- MOUNTING HEIGHT
See Battery Manufacturer
Instructions
Emergency maximum mounting height:
ExternalSwitch:26.4'
InternalSwitch:8.0'
Use a non-maring tool with
thin blade to safely remove louver
without causing damage
1a 1b
1c
Fully louvered Louver and lens
Louver and faceplate
2