Focal Point AirCore Bridge AUABG Installation guide

Type
Installation guide
1 of 8
IS0768 REV. C
©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
AirCore BridgeTM
AUABG
Configurations are run specific, please
consult factory drawings before
beginning installation.
Luminaires must be installed by a qualified
electrician (check with local and national
codes for proper installation).
To prevent electrical shock, disconnect
electrical supply before installation or
servicing.
Contractor is responsible for adequately
reinforcing walls and/or ceilings to support
fixture weight.
Focal Point, LLC accepts no responsibility
for inadequately reinforced walls and/or
ceilings.
The information contained in this drawing
is the sole property of Focal Point, LLC. Any
reproduction in part or whole without the
written permission of Focal Point, LLC is
prohibited.
POWER OFF
POWER ON
ATTENTION
SEE ADDITIONAL
INSTRUCTIONS
BEFORE YOU BEGIN COMPONENT KEY
INSTRUCTION KEY
U - Individual
S - Start of run
I - Intermediate
E - End of run
Flush Lens
FOCAL POINT SHIPPED INSTALLED
Joiner
(A46895-01)
Alignment Plate
(A46949-01)
Alignment Plate Screw
8-32 x 7/8"
(700366)
Joiner Screw
10-32 x 3/4"
(700365)
Product ID label
on reflector
AirCore Blade - Truss
AirCore Blade - Cantilever
Blade Mounting Bracket
8" - (A55758-01)
12" - (A55758-02)
16" - (A55758-03)
Blade Mounting
Bracket Screw
6-20 x 1/4"
(72026)
Pop-Down Lens
SHIPPED IN HARDWARE BAG
AirCore Technology
2 of 8
IS0768 REV. C ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
SEEM  INSTALLATION
21
4
Two cable grippers each for individual and start,
one for intermediate and end housings.
Follow Focal Point instructions for
Universal Suspension System assembly.
See IS0166
MAKE ELECTRICAL CONNECTION
35
CEILING INSTALLATIONS:
CEILING STRUT  PG 
DRYWALL/HARD SURFACE  PG 
GRID CEILING  PG 
INDIVIDUAL INSTALLATIONS
FOLLOW STEPS ,  & 
PROPERLY AFFIX JBOX
TO STRUCTURE ABOVE
INSTALL POWERED/UNPOWERED
JBOX ACCORDING TO LOCAL CODE
7 8
11
6
DO NOT OVERTIGHTEN.
Note: Screw head may not seat to bracket. Seat screw firmly.
Alignment Plate
Screw (700366) Joiner Screw
(700365)
DO NOT HANDLE BY LIP OF
ACOUSTIC MATERIAL
3 of 8
IS0768 REV. C ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
DRIVER SERVICE
1 2
Avoid all contact with LED surface,
LEDs are easily damaged!
AIRCORE BRIDGE TRUSS INSTALLATION
9
Repeat installation steps for second Seem 1 row (Truss only)
MOUNTING LOCATIONS  TRUSS
On-center spacing tolerance between suspension points
is critical for proper installation of AirCore Blades
7'
6'
8'
5'
84.75"
2152.7mm
72.00"
1828.8mm
60.00"
1524mm
72.75"
1847.9mm
48.00"
1219.2mm
60.75"
1543.1mm
95.00"
2413mm
84.00"
2133.6mm
7'
6'
8'
5'
84.75"
2152.7mm
72.00"
1828.8mm
60.00"
1524mm
72.75"
1847.9mm
48.00"
1219.2mm
60.75"
1543.1mm
95.00"
2413mm
84.00"
2133.6mm
7'
6'
8'
5'
84.75"
2152.7mm
72.00"
1828.8mm
60.00"
1524mm
72.75"
1847.9mm
48.00"
1219.2mm
60.75"
1543.1mm
95.00"
2413mm
84.00"
2133.6mm
7'
6'
8'
5'
84.75"
2152.7mm
72.00"
1828.8mm
60.00"
1524mm
72.75"
1847.9mm
48.00"
1219.2mm
60.75"
1543.1mm
95.00"
2413mm
84.00"
2133.6mm
4 of 8
IS0768 REV. C ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
2
Repeat installation of blade mounting brackets on
second Seem 1 row
3a
54
Install remaining AirCore Blades
Ensure bale is seated against Seem 1 housing.
Do not apply excessive pressure.
3b
1
Evenly space and install the blade mounting brackets on the Seem 1 run.
Refer to submittal drawings for specific installation dimensions of the blade mounting brackets.
Brackets may be installed prior to Seem 1 installation,
but it is recommended to do so after (as shown).
5 of 8
IS0768 REV. C ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
MOUNTING LOCATIONS  CANTILEVER WAVE
On-center spacing tolerance between suspension points
is critical for proper installation of AirCore Blades
MOUNTING LOCATIONS  CANTILEVER
On-center spacing tolerance between suspension points
is critical for proper installation of AirCore Blades
AIRCORE BRIDGE CANTILEVER/ CANTILEVER WAVE INSTALLATION
7'
6'
8'
84.75"
2152.7mm
64.75"
1644.7mm
64.75"
1644.7mm
72.75"
1847.9mm
95.00"
2413mm
64.75"
1644.7mm
18.375"
466.7mm
28.625"
727.1mm
6.375"
161.9mm
7'
6'
8'
84.75"
2152.7mm
64.75"
1644.7mm
64.75"
1644.7mm
72.75"
1847.9mm
95.00"
2413mm
64.75"
1644.7mm
18.375"
466.7mm
28.625"
727.1mm
6.375"
161.9mm
7'
6'
8'
84.75"
2152.7mm
64.75"
1644.7mm
64.75"
1644.7mm
72.75"
1847.9mm
95.00"
2413mm
64.75"
1644.7mm
18.375"
466.7mm
28.625"
727.1mm
6.375"
161.9mm
7'
6'
8'
5'
84.75"
2152.7mm
76.75"
1949.5mm
64.75"
1644.7mm
72.75"
1847.9mm
52.75"
1339.9mm
60.75"
1543.1mm
95.00"
2413mm
87.88"
2232mm
7'
6'
8'
5'
84.75"
2152.7mm
76.75"
1949.5mm
64.75"
1644.7mm
72.75"
1847.9mm
52.75"
1339.9mm
60.75"
1543.1mm
95.00"
2413mm
87.88"
2232mm
7'
6'
8'
5'
84.75"
2152.7mm
76.75"
1949.5mm
64.75"
1644.7mm
72.75"
1847.9mm
52.75"
1339.9mm
60.75"
1543.1mm
95.00"
2413mm
87.88"
2232mm
7'
6'
8'
5'
84.75"
2152.7mm
76.75"
1949.5mm
64.75"
1644.7mm
72.75"
1847.9mm
52.75"
1339.9mm
60.75"
1543.1mm
95.00"
2413mm
87.88"
2232mm
6 of 8
IS0768 REV. C ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
2
Measure the specified on-center spacing of the
AirCore Blades and install hang points
(strut installation shown for example)
3a
Install AirCore Blade onto blade mounting bracket prior to cable installation
Install first
Install second
1
Evenly space and install the blade mounting brackets on the Seem 1 run.
Refer to submittal drawings for specific installation dimensions of the blade mounting brackets.
Brackets may be installed prior to Seem 1 installation,
but it is recommended to do so after (as shown).
3c
3b
4
Install remaining AirCore Blades
5
Ensure bale is seated against Seem 1 housing.
Do not apply excessive pressure.
7 of 8
IS0768 REV. C ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
6
CEILING STRUT INSTALLATION
1 2
HARDWARE BY OTHERS
/" 
THREAD
WITH CANOPY WITHOUT CANOPY
3
8 of 8
IS0768 REV. C ©2022 Focal Point, LLC | 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com/reference
FOLLOW FOCAL POINT
INSTRUCTIONS FOR UNIVERSAL
SUSPENSION SYSTEM ASSEMBLY.
SEE IS
GRID CEILING INSTALLATION
1 32
3
DRYWALL/HARD SURFACE CEILING INSTALLATION
1 2
INSTALL /"  ANCHOR BY OTHERS
IN CEILING SUBSTRATE WITH CANOPY WITHOUT CANOPY
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Focal Point AirCore Bridge AUABG Installation guide