Rev-06-13-23INSTALLATION LED POWER SUPPLY - QTM-eLED+TW-AN
SURFACE MOUNTRECESSED MOUNT
AN-1 AN-2
0.875" KNOCKOUT 9X
(FOR 1/2" FITTINGS)
ISO VIEW
Mounted in the secondary wiring compartment only
Conduit Entry Locations Lutron Athena Node
BOTTOM VIEW
4.0"
8.0"
16
ADDITIONAL
SIDE
KNOCKOUTS
14.5"
SIDE VIEW
4.0"
14.5"
4.0"
8.0"
VERTICALHORIZONTAL RECESSED MOUNT
Plenum Door Required
Horizontal
Vertical
SURFACE SPACING SURFACE STACKING ROD SUSPENSION
9.5" O.C.
16" O.C.
19" O.C.
9.5" O.C.
9.5" O.C.
More Units can be stacked
More Units can be stacked
More Units can be stacked
NOTE: Rods not included.
RECESSED
SURFACE
ROD SUSPENSION (Vertical)
ROD SUSPENSION (Horizontal)
NOTE: Bracket can also be mounted
(Top & Bottom) for Vertical Mounts.
1/4" Rod Thru Hole
3/8" Rod Thru Hole
Double Sided
Key Hole
Athena nodes must be installed on the secondary side of power supply center and require 1.0” of clearance
in order to optimally function. Metal conduit must be 1.0” away from any node. Refer to the diagram above
for recommendations for conduit entry into secondary compartment.
Node And Conduit Entry Locations
Mounting Options