Q-TRAN QTM-eLED+WD-AWN LED Power Supply

Q-tran Q-TRAN QTM-eLED+WD-AWN LED Power Supply Installation guide

  • I've reviewed the installation instructions for the QTM-eLED+WD-AWN, QTM-eLED+WD and QTM-eLED+0-10V LED Power Supplies. This document provides important safety information, including the requirement for installation by a licensed electrician. It also details mounting options and safety precautions. I'm ready to answer your questions about these power supplies.
  • Who should install this power supply?
    What safety precautions should be followed during installation?
    Where should this power supply not be installed?
© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-08-03-23
INSTALLATION LED POWER SUPPLY - QTM-eLED+WD-AWN
Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
This power supply must be installed according to the National Electric
Code and local codes and ordinances.
This power supply is to be installed and serviced only by an licensed
electricians.
This power supply is to be installed so that it is not likely to be contacted
by people.
To avoid a hazard to children, account for all parts and destroy all
packaging materials.
Do not install in wet locations.
LOW VOLTAGE LIGHTING SYSTEM
CLASS: 3425-15
3425-95
COMPLIANT
Must be installed by licensed electrician.
© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-08-03-23
INSTALLATION LED POWER SUPPLY - QTM-eLED+WD-AWN
VERTICALHORIZONTAL RECESSED MOUNT
Plenum Door Required
Horizontal
Vertical
SURFACE SPACING SURFACE STACKING ROD SUSPENSION
9.5" O.C.
16" O.C.
19" O.C.
9.5" O.C.
9.5" O.C.
More Units can be stacked
More Units can be stacked
More Units can be stacked
NOTE: Rods not included.
RECESSED
SURFACE
NOTE: AWN-3 is available for QTM-eLED+WD and QTM-eLED+0-10V only.
AWN-1 AWN-2 AWN-1 AWN-2 AWN-3
ROD SUSPENSION (Vertical)
ROD SUSPENSION (Horizontal)
NOTE: Bracket can also be mounted
(Top & Bottom) for Vertical Mounts.
1/4" Rod Thru Hole
3/8" Rod Thru Hole
Double Sided
Key Hole
14.5"
4.0"
8.0"
ISO VIEW
SURFACE MOUNTRECESSED MOUNT
Athena nodes must be installed on the secondary side of power supply center and require 1.0” of clearance
in order to optimally function. Metal conduit must be 1.0” away from any node. Refer to the diagram above
for recommendations for conduit entry into secondary compartment.
Mounted in the secondary wiring compartment only
Conduit Entry Locations Lutron Athena Node
0.875" KNOCKOUT 9X
(FOR 1/2" FITTINGS)
BOTTOM VIEW
4.0"
8.0"
16
ADDITIONAL
SIDE
KNOCKOUTS
14.5"
SIDE VIEW
4.0"
Node And Conduit Entry Locations
Mounting Options
© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-08-03-23
INSTALLATION LED POWER SUPPLY - QTM-eLED+WD-AWN
SECONDARY
PRIMARY
: for interior
LED DRIVER 2
(120V - 277V)
LED DRIVER 1
(120V - 277V)
LED DRIVER 3
(120V - 277V)
GND
HOT
NEU
NEU HOT GND+24V Cool− Warm− +24V Cool− Warm− +24V Cool− Warm− 0-10V 0-10V 0-10V
*By others.
Warm
Cool
+24V
*By others.
Warm
Cool
+24V
*By others.
Warm
Cool
+24V
Warm-Dim
Module
Warm-Dim
Module
Warm-Dim
Module
Driver with Lutron Athena Node
QTM-eLED-300W+WD-AWN-3
© 2023 Q-Tran Inc. All rights reserved | 155 Hill St. Milford, CT 06460 | 203-367-8777 | [email protected] | www.q-tran.com Specification subject to change. Rev-08-03-23
INSTALLATION LED POWER SUPPLY - QTM-eLED+WD-AWN
CSA Requirements
Suitable for indoor use
This power supply must be installed according to the National Electric Code and local codes and ordinances and in
accordance with applicable installation code by a person familiar with the construction and operation of the product and
the hazards involved.
Wear rubber shoes and work on a sturdy wooden or fiberglass ladder.
This power supply is to be installed in a location where it is not likely to be contacted by non-electricians.
To avoid a hazard to children, account for all parts and destroy all packaging materials.
/