Danfoss SpeedUp Eco - Direct load User guide

Type
User guide
Application sheet
SpeedUp Eco
Parquet
Direct load
1
2
3
4
5
1 Parquet ≥ 14 mm
2 Sound insulation 2 mm
3 SpeedUp Eco heat panel + FH composite pipe 30 mm
4 Support batten (30mm)
5 Load bearing panel ≥ 15 mm
6 Wood bre insulation 20 mm
7 SpeedUp Eco perimeter insulation
8 If necessary moisture barrier
Floor nish ≥ 14 mm Parquet
Construction height ≥ 81 mm Height including oor nish
Weight 31 kg / m² Weight including oor nish
Thermal resistance R 1,26 m²K / W The minimum thermal resistance requirement of DIN EN 1264 is
fullled.
Thermal transmission coecient U 0,70 W / m²K If the architectural design species better thermal insulation, this
must be taken into account.
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 1,0 kN Sum point load ≤ design load; please notice special heavy ob-
jects (aquaria etc.)
Impact subsonic noise reduction 22 dB Test value according to DIN ISO 140-8; applies to concrete slabs
thicker than 12 cm (DIN 4109: m’ > 276 kg/m²)
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Requirements & special features
A level, smooth and structurally sound surface is necessary for full surface contact with
the heating elements (elevated requirements according to DIN 18202 Table 3, row 4).
Structural sealing according to DIN 18195 must be placed beneath the oor panel in
case of structures facing the ground, and otherwise on the unnished oor. The R value
must be increased if the groundwater level is less than or equal to 5 m. A U value not
exceeding 0.5 W/m²K must be maintained in existing buildings and additions with areas
up to 50 m². If necessary, protect oorboards and prefabricated parquet against mois-
ture penetration from below (vapour barrier). Observe all installation instructions and
manufacturer’s instructions.
Additional insulation
20 mm wood bre insulation 150kPa, renovation: 50 mm wood bre insulation 150 kPa,
WLG 050
Construction
According to EnEV, EN 1264, DIN 1055, 18195 and 18202
Construction number 87
Technical Data Floors/ceilings facing unheated rooms or the ground
6
7
8
© Danfoss 11/2008
VA.CS.K1.02