Danfoss SpeedUp ECO - Gypsum fibre element User guide

Type
User guide
Application sheet
SpeedUp Eco
Carpet / tiles / parquet / laminate / synthetics
Gypsum bre element (Fermacell)
1
2
3
4
5
1 Carpet / tiles / parquet
2 Gypsum bre element (Fermacell) 25 mm
3 SpeedUp Eco heat panel + FH composite pipe 30 mm
4 Support batten (30mm)
5 Wood bre insulation 30 mm
6 SpeedUp Eco perimeter insulation
7 If necessary moisture barrier
Floor nish NA mm Carpet / tiles / parquet / laminate / synthetics
Construction height 85 mm Height excluding oor nish
Weight ~ 45 kg / m² Weight excluding oor nish
Thermal resistance R 1,35 m²K / W The minimum thermal resistance requirement of DIN EN 1264 is
fullled.
Thermal transmission coecient U 0,66 W / m²K If the architectural design species better thermal insulation, this
must be taken into account.
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 1,0 kN Sum point load ≤ design load; please notice special heavy ob-
jects (aquaria etc.)
Impact subsonic noise reduction 28 dB Test value according to DIN ISO 140-8; applies to concrete slabs
thicker than 12 cm (DIN 4109: m’ > 276 kg/m²)
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Requirements & special features
A level, smooth and structurally sound surface is necessary for full surface contact with
the heating elements (elevated requirements according to DIN 18202 Table 3, row 4).
Structural sealing according to DIN 18195 must be placed beneath the oor panel in case
of structures facing the ground, and otherwise on the unnished oor. The R value must
be increased if the groundwater level is less than or equal to 5 m. A U value not exceed-
ing 0.5 W/m²K must be maintained in existing buildings and additions with areas up to
50 m². The screed thicknesses must be adjusted in case of higher design load or point
load values. Observe all installation instructions and manufacturer’s instructions.
Additional insulation
30 mm wood bre insulation 150 kPa; alternative: 20 mm Gutex Thermosafe wd ≥ 50 kPa.
Existing buildings: wood bre insulation 60 mm 150 kPa, WLG 050; alternatively 40 mm
50 kPa, WLG 040.
Construction
According to EnEV, EN 1264, DIN 1055, 4108 and 18202
Construction number 53
Technical Data Floors/ceilings facing unheated rooms or the ground
6
7
© Danfoss 11/2008
VA.CS.G1.02
Danfoss HES
  • Page 1 1

Danfoss SpeedUp ECO - Gypsum fibre element User guide

Type
User guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI