Application sheet
SpeedUp Eco
Tile / natural stone
Strongboard tile and laminate
1
2
3
4
5
1 Tile / natural stone incl. adhesive ≥ 12 mm
2 Strongboard tile and laminate 5 mm
3 SpeedUp Eco heat panel + FH composite pipe 30 mm
4 Support batten (30mm)
5 Load bearing panel 22 mm
6 Wood bre insulation - additional insulation 20 mm
7 SpeedUp Eco perimeter insulation
8 If necessary moisture barrier
Floor nish ≥ 8 mm Tile dimensions: min. 10 x 10 cm; max. 40 x 60 cm;
Natural stone thicknesses from 10 mm; Grout width 3 mm
Construction height ≥ 89 mm Height including oor nish
Weight ~ 53 kg / m² Weight including oor nish
Thermal resistance R 1,32 m²K / W The minimum thermal resistance requirement of DIN EN 1264 is
fullled.
Thermal transmission coecient U 0,67 W / m²K If the architectural design species better thermal insulation, this
must be taken into account.
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 1,0 kN Sum point load ≤ design load; please notice special heavy ob-
jects (aquaria etc.)
Impact subsonic noise reduction 22 dB Test value according to DIN ISO 140-8; applies to concrete slabs
thicker than 12 cm (DIN 4109: m’ > 276 kg/m²)
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Requirements & special features
Structural sealing according to DIN 18195 must be placed beneath the oor panel in case
of structures facing the ground, and otherwise on the unnished oor. The R value must
be increased if the groundwater level is less than or equal to 5 m. A U value not exceed-
ing 0.5 W/m²K must be maintained in existing buildings and additions with areas up to
50 m². Wooden joist oor, free from twist eects, free of deection Strongboard is only
approved for use with Danfoss components. Lay tiles using the combined method with
Mapei adhesive and Elastorapid (see installation instructions). Observe all installation
instructions and manufacturer’s instructions.
Additional insulation
20 mm wood bre insulation 150kPa, renovation: 50 mm wood bre insulation 150 kPa,
WLG 050
Construction
According to EnEV, EN 1264, DIN 1055, 4108 and 18202
Construction number 99
Technical Data Floors/ceilings facing unheated rooms or the ground
6
7
8
© Danfoss 11/2008
VA.CS.S1.02
Danfoss HES