  • Hello! I am an AI chatbot trained to assist you with the Hagerco 7000 Series - Grade 1 Heavy Duty - Overhead Door Holder and Stop Installation guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
C
A
B
1"
25.4
BRACKET IS
MORTISED
INTO FRAME
End cap
Spring stop
Jamb Arm
Slider Arm
Channel body
** All Dimensions are in Inches and Millimeters
1. PARTS
Screw Chart
Pre Installation Notes:
1. Hollow metal frames must be properly reinforced with 3/16" [5] thick plates that are at least 12" [305] long.
2. Hollow metal doors must be properly reinforced with 3/16" [5] as shown on page 3.
3. Hold open (7017) and Friction (7015) are not permitted for use on fire doors.
4. Stop only (7016) is subject to job specification for fire door use.
1) Determine frame opening and desired degree of door opening. With
this information use the chart below to locate, mark and drill the "A" and
"C" channel mounting hole locations. Install the channel body with spring
end toward hinges.
2) Locate and mark desired dimension "B" Cut out the "Jamb Bracket
Template" from the bottom of page 3 and align on frame to locate and
drill the four jamb bracket mounting holes. Install the jamb bracket.
3)
Dimension 'A' is taken from the door edge while dimension 'B' is
taken from the jamb face
2. INSTALL OVERHEAD DOOR HOLDER/STOP (ODHS) (Right Hand Shown)
7000 SERIES- HEAVY DUTY
CONCEALED DOOR STOPS AND
HOLDERS - INSTRUCTIONS
REV: 07
DRAWING NO: I-CL00317
SHEET 1 OF 3
HAGER COMPANIES
139 Victor Street, St. Louis, MO 63104 - (800) 325-9995 - Fax (800) 782-0149
Jamb Arm
Slider Arm
Spring stop
Slider bar
Jamb Arm
Slider Arm
Slider bar
Spring stop
Hold Open adjustment screw
Hold Open
engagement switch
Friction Adjustment Screw
Hold Open engagement
switch
OFF
position
Hold Open engagement
switch
ON
position
Open the door then align and insert the
Jamb Arm into the Slider Arm.
If it applies, disengage the hold open
engagement switch (step 5a). With the
door held at the desired maximum opening
angle, position the slider bar against the
stop spring. Then tighten the three friction
screws. Tighten the screws to
12 ft-lbs
[16.3 Nm].
If dead stop is required, position the door
5-7 degrees less then the desired dead
stop, and tighten as instructed above.
5b. OPTIONAL FRICTION HOLD OPEN (7015)
Using a flat head screw driver, turn the
friction adjustment screws clockwise to
increase the friction and counter-
clockwise to lower the friction.
Using a Philips
screwdriver, turn
the hold open
adjustment screw
clockwise to
increase the hold-
open tension and
counter-clockwise
to lower the
tension.
3. ARM ALIGNMENT
4. SETTING DESIRED DOOR OPENING
5a. OPTIONAL HOLD OPEN (7017)
3x Arm Adjustment Screws
7000 SERIES- HEAVY DUTY
CONCEALED DOOR STOPS AND
HOLDERS - INSTRUCTIONS
REV:07
DRAWING NO: I-CL00317
SHEET 2 OF 3
HAGER COMPANIES
139 Victor Street, St. Louis, MO 63104 - (800) 325-9995 - Fax (800) 782-0149
DOOR REINFORCEMENT
FRAME REINFORCEMENT
Y
X
1/2"
12.7
1-5/8"
41.3
Z
1-9/32"
32.6
W
5-5/32"
131.3
2"
50.8
1-3/4"
44.5
3/16"
4.8
Body Cut-Out
Arm Cut-Out
7/16" Hold Open Selector Hole
and Screw Head Clearance Cut-Out
optional for use on
7017 ONLY
1-1/4"
31.8
A
A
Single Action - Top View
Double Action - Top View
C
L
Hinge Pivot
C
L
B
B
Section B-B
Section A-A
3/8"
9.5
1"
25.4
23/32"
18.3
5/8"
16
23/32"
18.3
3-1/2"
88.9
5/16"
7.9
11/16"
17.5
4X
9/32"
7
THRU ALL
1/2"
13
X 100°
3/8"
9.7
HINGE SIDE
1/4"
6.4
DOOR PREP FOR ALL STYLES OF HOLD OPENS AND STOPS
Cut out and tape parallel to frame at
the "B" measuremnt from step 2.
JAMB BRACKET TEMPLATE
B
REV:07
DRAWING NO: I-CL00317
SHEET 3 OF 3
HAGER COMPANIES
139 Victor Street, St. Louis, MO 63104 - (800) 325-9995 - Fax (800) 782-0149
7000 SERIES- HEAVY DUTY
CONCEALED DOOR STOPS AND
HOLDERS - INSTRUCTIONS
/