Hager 2-679-0630 Installation Instructions Manual

Category
Security access control systems
Type
Installation Instructions Manual

Hager 2-679-0630 is a delayed egress wall controller that provides comprehensive instructions for door operation, especially for individuals with hearing or visual impairments. Its key features include:

  • Egress Delay: Delays egress through the door for 15 or 30 seconds, allowing personnel or security to respond.
  • Built-In Annunciation: Provides clear instructions in armed mode, nuisance mode, irreversible egress mode, release mode, and digital countdown mode.
  • Field Selectable Voice Notification: Offers a choice of male voice with a security message or a female voice with a safety message.

Hager 2-679-0630 is a delayed egress wall controller that provides comprehensive instructions for door operation, especially for individuals with hearing or visual impairments. Its key features include:

  • Egress Delay: Delays egress through the door for 15 or 30 seconds, allowing personnel or security to respond.
  • Built-In Annunciation: Provides clear instructions in armed mode, nuisance mode, irreversible egress mode, release mode, and digital countdown mode.
  • Field Selectable Voice Notification: Offers a choice of male voice with a security message or a female voice with a safety message.
Delayed Egress Wall Controller
Installation Instructions
I-EA00052
Rev 3, Rev Date: 03/24/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
Verbal Exit Instructions or
Alarm Tone Only and
Digital Countdown Display
·
Stop Employee Theft
·
Stop Retail Shoplifting
·
Restrict Airport Patrons
·
Restrict Wandering Patients
The integral verbal message, digital countdown display and sign
provide comprehensive and clear instructions of the door operation
for persons without prior knowledge of the exit delay, including the
sight and hearing impaired.
The digital keypad eliminates the need to carry and locate keys for
reset and bypass functions.
Features:
Egress Delay
· 15 or 30 second exit delay
· 1 or 2 second nuisance delay
Built-In 3 Function keypad
· Alarm and lock reset
· 1 to 30 second bypass
· Sustained bypass
· Additional keyswitch optional
Control Inputs
· 1 to 30 second request-to-exit and
bypass input with anti-tailgate and
jumper selectable door prop alarm.
· Reset
Built-In Annunciation
· Armed mode
· Nuisance mode
· Irreversible egress mode
· Release mode
· Digital countdown mode
· Field selectable voice notification or
tone
· Field selectable male voice with
security message or female voice with
safety message
Monitoring Outputs
· Armed mode
· Egress initiation status
· Released status
Trigger Modes
· Egress alarm triggered by Push Bar
· Trigger input from external device
field selectable (N/O or N/C)
Code Compliance
· IFC International fire Code
· IBC International Building Code
· NFPA 101 Life Safety Code
· NFPA 1 Uniform Fire Code
· California Building Code
· Field selectable automatic or manual power up after emergency release or power
loss. Use of manual power up complies with California Building Code (OSHPD)
requirements.
· Choice of Mounting
· Recessed mounted
(3 gang metal plaster ring included)
· Surface mounted with optional 3
gang box (2-679-0641)
· Optional shroud (2-679-0642) to be
used with (2-679-0641) surface box.
2-679-0630
WALL CONTROLLER
4500/4600
RIM MOUNT OR
VERTICAL ROD*
EXIT DEVICES
NOTE: Hager 2908 Power Supply required
Application:
When unauthorized egress is initiated 4500 DE
delays egress through the door
for 15 seconds (or 30 seconds). Meanwhile,
the person exiting must wait while personnel
or security responds. The door unlocks after
15 seconds have elapsed permitting egress.
When powered by a fire control supervised
power supply, the lock will release
immediately in an emergency.
SYSTEM SPECIFICATIONS
INPUT VOLTAGE INPUT VOLTAGE
MAX CURRENT DRAW
(SINGLE)
430mA @ 24 VDC
(TANDEM) 680mA @ 24 VDC
MONITOR RELAYS
CONTACT RATING
1 AMP @ 12/24 VDC
(RESISTIVE)
TEMPERATURE
o
0 C 70 C
o
* Note: If being used with a Surface Vertical
Rod Exit Device, rod covers are
required for security.
Page 1 of 7
Delayed Egress Wall Controller
Installation Instructions
I-EA00052
Rev 3, Rev Date: 03/24/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
SURFACE MOUNT 3 GANG BOX OVER
EXISTING RECESSED 2 GANG BOX
2) Carefully insert unit and
secure with screws supplied.
1) Attach optional 3 Gang Surface
Mount Box to existing recessed 2
gang box using screws supplied.
RECESSED DRY WALL MOUNTING
KEY CYLINDER INSTALLATION
WITH KEY CYLINDER IN PROPER
POSITION INSIDE SWITCH BLOCK,
TIGHTEN THE SET SCREW TO
LOCK CYLINDER IN PLACE.
1-1/4” KEY CYLINDER
REQUIRES COLLAR
3-3/4"
1) Cut hole in dry wall to
dimensions shown.
2) Mount wall bracket
over hole.
3) Carefully insert unit and
secure with screws supplied.
5-3/4
PUSH UNTIL ALARM
SOUNDS
.
DOOR CAN BE
OPENED IN
15
SECONDS
.
PUSH UNTIL ALARM
SOUNDS
.
DOOR CAN BE
OPENED IN
15
SECONDS
.
*ETW/
ETM
6
Wires
4
Wires
1-1/8” KEY
CYLINDER
3902
2908
Power Supply
2908
Power Supply
*ETW/
ETM
*ETW = Electric Through Wire Only
ETM = Electric Through Wire w/Monitoring
Page 2 of 7
Delayed Egress Wall Controller
Installation Instructions
I-EA00052
Rev 3, Rev Date: 03/24/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
RECOMMENDED MOUNTING PROCEDURE
WIRE UNIT AS SHOWN
(SHOWN WITH NO OPTIONS).
SLIDE PACKING FOAM BETWEEN WALL
AND UNIT TO PREVENT DAMAGE TO FACEPLATE
USE 1-1/4” SCREWS SUPPLIED WITH
WALL MOUNT FRAME TO HANG UNIT
TEMPORARILY FOR WIRING PURPOSES
W
H
T
W
H
T
R
E
D
B
L
K
TO
PANIC DEVICE
FROM
POWER SUPPLY
Page 3 of 7
Delayed Egress Wall Controller
Installation Instructions
I-EA00052
Rev 3, Rev Date: 03/24/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
**JUMPER J1 (DOOR PROP)
INSTALLED: The 4500 DE will enter the alarm mode if the
door is held open past the request to exit period.
REMOVED: The 4500 DE will remain unlocked if the door
is held open past the request to exit period. No alarm will
sound.
For the 4500 DE to relock and rearm upon closure of the
door, DPS is required.
*Door Contact or Power Transfer Hinge by DPS required for
Anti-Tailgate and Door Prop operation.
WARNING!
CONTACT THE AUTHORITY HAVING JURISDICTION FOR APPROVAL
PRIOR TO SELECTING DELAY TIME OR PWR-UP SETTINGS
DIP SWITCH
SETTINGS
15
30
1
2
15 20 30 1
N/CN/O
UNLOCKED LOCKED
VOICE/
TONE
TONE
ONLY
FEMALE
MSG
MALE
MSG
ON
DELAY
TIME
[ON]
[OFF]
1 2
3 4
5
6 7 8
NUISANCE
DELAY
REX
PERIOD
TRIGGER
TYPE
PWR UP
STATE
ALARM
TYPE
MESSAGE
JUMPER J1**
PWR
LOCK
RED R
NO C
TRIG
REX
RESET
C NOC NOC NO
To
Power
Supply
- +
- +
TANDEM UNIT
(PAIR OF DOORS)
WHT
WHT
BLK
RED
WHT
WHT
BLK
RED
POWER
TRANSFER HINGE
POWER
TRANSFER
HINGE
*DPS
*DPS
To
Power
Supply
PWR
LOCK
RED R
NO C N
TRIG
REX
RESET
C NOC NOC NO
WHT
WHT
BLK
RED
POWER
TRANSFER
HINGE
SINGLE
DOOR
DPS
*
- + - +
2-679-0630
2-679-0630
Wiring Diagrams and Options
Optional Features
External Request to Exit: The REX TERMINAL is a
wet 12/24VDC output to be used with a keypad such as
a 2915.
External Reset: The RESET TERMINAL is a wet 12/
24VDC output to be used with a keypad such as a
2915.
Lock/Unlock Monitoring: The GRN RLY TERMINAL
is a dry relay that is activated when the LOCK output is
activated.
Alarm Monitoring: The RED RLY TERMINAL is a dry
relay that is activated when the Alarm is activated.
Page 4 of 7
Delayed Egress Wall Controller
Installation Instructions
I-EA00052
Rev 3, Rev Date: 03/24/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
System Operation
The door is unlocked until the REX
timer has expired or until the door
has been opened and then closed.
AUTHORIZED EGRESS [REX] (Green LED Solid)
Door Closed
- -
- -
- -
- -
Door has been
opened
Keypad Code 22
*
The door is still locked and secure. The display is counting
down with audible alarm/voice instructions. Once the display
reaches “00, the door will unlock.
15 14 01
DELAYED EGRESS MODE
RESET [Armed] (Green LED solid)
Keypad Code 11
*
The door is locked
and secure
15
30
or
-
-
POWER-UP LOCKED
The door is
locked and
secure
15
30
or
POWER-UP UNLOCKED
The door is unlocked. To enter the
Armed Mode, turn the keyswitch to
Reset or enter the Reset Code
11 ” on the keypad
*
00
00
The door is unlocked and
has been opened
ALARMED UNLOCKED [Alternating Display]
- -
- -
- -
The door is unlocked and the alarm
is sounding. To return to Armed
Mode, close the door and turn the key
to Reset or enter the Reset Code “11
on the keypad
*
BYPASS [Extended Unlock] (Green LED Flashing)
Door Closed
- -
- -
- -
- -
Door has
been opened
Keypad Code 33
*
The door is unlocked indefinitely. To return to
Armed Mode, turn the keyswitch to Reset or
enter the Reset Code “11 “on the keypad.
*
KP
RST
C
NO
C
NO
C
NO
TRIG
REX
RESET
*
Returning the Keypad to Factory Default Settings
Short the KP RST terminal located on the main controller board.
Press 99# 1234 8# to enter programming mode and erase all users.
Press 3#1#2# . Sets the Output #1 (Reset) for 2 seconds.
Press 3#2#2# . Sets the Output #2 (Auth Exit) for 2 seconds.
Press 3#3#0# . Sets the Output #3 (Bypass) for latching.
Press 1#02#11#2# . Adds user # 2 with a code of 11 . [Reset]
Press 1#03#22#3# . Adds user # 3 with a code of 22 . [Auth Exit]
Press 1#04#33#4# . Adds user # 4 with a code of 33 . [Bypass]
Press to exit programming mode.
Remove the shorting jumper from the KP RST terminal.
*
*
*
*
*
*
*
**
*
*
*
Page 5 of 7
Delayed Egress Wall Controller
Installation Instructions
I-EA00052
Rev 3, Rev Date: 03/24/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
*
Erase All Users (Option 8)
To ERASE ALL USERS!!
1) Enter Programming Mode.
2) Press 8# .
3) *Exit Programming Model
All users are erased and the Default Master Code is reset to
1234
.
Keypad Programming
KEYPAD STATUS LEDS
GREEN
Power on, No errors, No outputs are active
Slow Flash:
Steady:
No errors, At least one output is active
RED
General error, invalid code entered
Slow Flash:
Steady:
Error condition: At least one output is active
FACTORY PROGRAMMED CODES
1234
Master Code (default)
11
Reset
22
Authorized Exit (Rex)
Function
Pin
Code
33 Bypass (toggle on)
User
No.
1
2
3
4
Output
Code
NA
2
3
4
*
*
*
*
If the factory programmed codes are acceptable for your
installation, no additional programming is required.
*
Entering and Exiting Programming Mode
Press 99# Master Code to enter programming mode.
For example:
99# 1234 Enters programming mode using the Default Master Code.
Press to exit programming mode.
*
**
YELLOW
Keypad is in Programming Mode
For ADA requirements, it will light each time
a key is pressed
Slow Flash:
Single Flash:
*
Adding a User / Changing User Pin Codes (Option 1)
To add a user:
1) Enter Programming Mode.
2) Press 1# User Number (2 digits)# New Pin Code# Output Code # .
For example:
99# 1234 1# 05# 55# 2# adds user 5's pin code (55) as one that will activate authorized exit.
3) *Exit Programming Mode.
*
*
*
Deleting a User (Option 2)
To delete a user:
1) Enter Programming mode.
2) Press 2# User Number (2 digits)# .
For example:
99# 1234 2# 05# deletes user 5.
3) *Exit Programming mode.
*
*
Changing the Master Code
User 1 is always used as the Master Code and is required to access keypad programming. The Factory Default Master Code is
1234 . It is strongly recommended that a new Master Code is assigned after installation. WRITE DOWN THE NEW CODE.
If the master code is lost, you must use the keypad reset jumper on the main circuit board to enter programming mode by
using the Default Master Code (See Page 5).
To Change the Master Code (User 1)
1) Enter Programming Mode.
2) Assign new Master Code : Press 1# 01# New Pin Code# Output Code # .
For example:
99# 1234 1# 01# 3871# 0# changes the Master code from 1234 to 3871.
3) *Exit programming mode.
*
*
*
*Multiple options may be performed without
exiting programming mode.
Page 6 of 7
Delayed Egress Wall Controller
Installation Instructions
I-EA00052
Rev 3, Rev Date: 03/24/15
Always visit www.hagerco.com for the latest Installation Instructions
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995
User
Number
Name
PIN
Code
User
Number
Name
PIN
Code
Recommended Programming Steps
1) Test the controller to verify that all default codes are working as expected.
2) Record all desired users, names, and PIN codes in the table below.
3) Enter programming mode.
4) Delete all default users using the “Delete All Users” option on page 6.
5) Change the Master Code to the desired Master Code.
6) Exit programming mode.
7) Enter programming mode using the new Master Code to test it.
8) Add all users in the table below.
9) Test all users and verify for desired functionallity.
Page 7 of 7
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7

Hager 2-679-0630 Installation Instructions Manual

Category
Security access control systems
Type
Installation Instructions Manual

Hager 2-679-0630 is a delayed egress wall controller that provides comprehensive instructions for door operation, especially for individuals with hearing or visual impairments. Its key features include:

  • Egress Delay: Delays egress through the door for 15 or 30 seconds, allowing personnel or security to respond.
  • Built-In Annunciation: Provides clear instructions in armed mode, nuisance mode, irreversible egress mode, release mode, and digital countdown mode.
  • Field Selectable Voice Notification: Offers a choice of male voice with a security message or a female voice with a safety message.