Hagerco 5200 Series - Grade 1 Heavy Duty - Door Closer Installation guide

Type
Installation guide
BACKCHECK VALVE
CLOSER BODY
PARALLEL
ARM BR
ACKET
POWER ADJUSTMENT SHAFT
REGULAR ARM/TO
P
JAMB SHO
E
CONNECTING RO
D
INSE
RT CUTOUTS
COVER INSE
RT
FOREAR
M
SCRE
W
SCREW
PACK
MAIN AR
M
CLOSER ARM
CLOSER C
OVER
LATCH VALVE
SWEEP
VALVE
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 • Fax (800) 782-0149
TOOLS REQUIRED
COMPONENT
PARTS
ME
TAL
1/4"- 20
#7
3/16"
WOOD
Self Drilling Screws
Wood and Metal
For wood, drill 3/16" hole
Sle
eve Nut and Bolt
Drill 9/32" thru from Closer Side
3/8" Drill other Sid
e
Machine Screws
#7 Drill, 1/4"- 20 Tap
An incor
rectly installed or
imp
roperly adjusted door closer
can cause p
roperty damage or
personal injur
y. These installation
instructions should be followe
d
to avoid the possibility o
f
misapplication or misadjustment
.
NOTE: For special applications, a separate door
and frame preparation template is packed wit
h
these instructions. Use this instruction sheet fo
r
installation sequence and closer adjustments onl
y.
Dimensions are based on standard doors an
d
frames with 1/8" clearance, 5/8" stops, an
d
square edge doors.
Door and frame must be properly reinfo
rced.
Non-Handed Door Closers
.
• These door closers should NOT be installed on the exposed side (weather side) of exterior doors.
Regular Arm
Installatio
n
See Page
2
Left Hand Door - LH
Right Hand Reverse - RH
R
Regular Arm
Installatio
n
See Page
2
Right Hand Door - RH
Left Hand Reverse - LH
R
Top Jamb
Installatio
n
See Page
5
Top Jamb
Installatio
n
See Page
5
Left Hand Door - LH
Right Hand Reverse - RHR
Right Hand Door - R
H
Left Hand Reverse - LH
R
Parallel Arm
Installatio
n
See Page
s
3 &
4
Parallel Ar
m
Installatio
n
See Page
s
3 &
4
Left Hand Door - LH
Right Hand Reverse - RH
R
Right Hand Door - R
H
Left Hand Reverse - LH
R
5200 Series Door Closer
Installation Instruction
s
I-CL00187 R2
Check building and fire codes to
see if your application requires
the use of sleeve nuts and bolts
.
NOTE: For Top Jamb
Applicatio
n
A longer connecting
rod is required for
reveals greater
than 3" (76 mm
)
Reveal
FRAME
WHEN ASSEMBLING TO SPINDLE
PINION FLAT
L
H
R
POSITION OF MAIN ARM
RIGHT HAND DOOR
90 RIGHT ANGL
E
1-3/8"
(35 mm)
1-3/4"
(44 mm
)
1"
(25 mm
)
12"
(305 mm
)
5-1/2
"
(140 mm)
3/4
"
(19 mm)
A
1. PARTS
3. INSTALL CLOSER
2. MARK AND DRILL HOLES ( Right Hand Shown)
4. INSTALL MAIN ARM
5. INSTALL MAIN ARM AND
CONNECTING
ROD
7. ADJUSTMENTS
COVER
Select hand of door and degree
of door opening. Fold template
on
the corresponding line for
desired
degree of door opening
and hand. Match this line with
the
hinge edge of door and
attach template to door. Be sure
frame
line on template lines up
with
the bottom edge of frame
face. Mark, prep and drill/tap
1/4"-20
holes for closer body
and
jamb shoe mounting screws.
Remove template and use mounting screws
to install the closer body to the door and the
jamb shoe to the frame. Closer body should
be oriented so that the speed regulating valves
are toward the hinge stile of doo
r.
Slide cover over closer body and secure
by tightening screws.
Orient main arm so that the “H”, located on
the main arm, lines up with the flat on th
e
spindle. Press arm down on spindle an
d
secure with spindle bolt
.
Slide connecting rod into forearm of main arm.
Rot n down forearm screw.
Door Opening Dimension “A
To 100
7-1/2
"
(191 mm
)
6"
(152 mm
)
4-1/2
"
(114 mm
)
101 to 13
0
131 to *18
0
*Door/Wall/Hardware/Jamb
conditions permitting
Speed regulating valves toward hinge edge
5200 Series Door Closer - Regular Arm
Installation Instruction
s
I-CL0087 R2
2
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 • Fax (800) 782-0149
See Adjustments on Page
6 for setting Spring
Powe
r, Sweep Speed,
Latch Speed, and
Backcheck.
NOTE: Do not fully unscrew valves or
hydraulic fluid will leak and closer will
no longer be functional
.
Identify direction of hold-open nut according to hand of
door and mount arm.
Adjust by loosening hold-open nut, then open door to
desired position and tighten hold-open nut securely.
6. OPTIONAL HOLD-OPEN ARM
RH
LH
8. INSTALL COVER
R
o
t
a
t
e
4
5
˚
3-1/2"
(89 mm)
3/4"
(19 mm)
12"
(305 mm)
Top of
Door
B
Frame
(Center on Hinge)
(Center on Hinge)
2-3/4"
(70 mm)
7/16"
(11 mm)
2"
(51 mm)
A
3/8"
(10 mm)
1/2"
(13 mm)
Speed regulating valves toward lock stile
CONNECTING ROD
1. PARTS
3. INSTALL CLOSER
2. MARK AND DRILL HOLES ( Right Hand Shown)
4. INSTALL CONNECTING ROD
5. INSTALL MAIN ARM
Select hand of door and the degree of door
opening. Fold template on the corresponding line
for desired degree and hand. Fold or cut upper
corner illustrated on template and align template
with the hinge edge of doo
r. At the “Frame Stop
Line” fold toward you and attach template to doo
r.
Mark, prep and drill/tap 1/4"-20 holes for closer
body and parallel arm bracket mounting screws
.
Use adjustable wrench to rotate spindle 4 counte
rclockwise for Right Hand
Door or clockwise for Left Hand Doo
r. Place main arm on spindle so that the
“R(Right Hand Door) or “L(Left Hand Door) lines up with the spindle flat.
Secure main arm and spindle by tightening spindle bolt
.
Remove template and use
mounting screws to install the
closer body to the door and
the parallel arm bracket to
the frame soffit. Closer body
should be oriented so that the
speed regulating valves are
toward the lock stile of door.
For parallel arm application only, remove regular arm /
top jamb shoe. Attach connecting rod to the parallel
arm plate
.
5200 Series Door Closer - Parallel Arm
Installation Instruction
s
I-CL00187 R2
3
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 • Fax (800) 782-0149
Door Opening
To 120
*121 to 18
0
9-1/2
"
(241mm
)
3-3/4
"
(95mm
)
7"
(178mm
)
1-1/4
"
(32mm
)
*Door/
Wall/Hardware/Jamb
conditions permitting
See Adjustments on
Page 6 for setting
Spring Powe
r, Sweep
Speed, Latch Speed,
and Backcheck.
NOTE: Do not fully unscrew valves
or hydraulic fluid will leak and closer
will no longer be functional
.
Identify direction of hold-open nut according to hand of
door and mount arm.
Adjust by loosening hold-open nut, then open door to
desired position and tighten hold-open nut securely.
7. OPTIONAL HOLD-OPEN ARM
LH RH
6. INSTALL MAIN ARM AND CONNECTING ROD
8. ADJUSTMENTS 9. INSTALL COVER
Slide connecting rod into forearm of main arm.
Rotate main arm until the pivot point is 1-1/2" from door su
rface.
While holding arm in this position, tighten down forearm scre
w.
5200 Series Door Closer - Parallel Arm
Installation Instruction
s
I-CL00187 R2
a)
b) c)
4
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 • Fax (800) 782-0149
1-1/2
"
(38 mm)
1-1/2"
(38 mm)
COVER
Slide cover over closer body and
secure by tightening screws.
12"
(305 mm
)
Top of
Fram
e
A
3/4"
(19 mm)
1/2"
(13 mm
)
1-7/8
"
(48 mm
)
1-3/4"
(44 mm)
5-1/2"
(140 mm)
L
H
R
1. PARTS
3. INSTALL CLOSER
2. MARK AND DRILL HOLES (Right Hand Shown)
4. INSTALL MAIN ARM
5. INSTALL MAIN ARM AND
CONNECTING
ROD
7. ADJUSTMENTS 8. INSTALL COVER
COVER
MAIN ARM
CONNECTIN
G
RO
D
MAIN
ARM
Select hand of door and the degree of door
opening. Separate template sections “A” and
“B”. Fold template on the corresponding line
for desired degree and hand. Match this line
with the hinge edge of door and attach template
to doo
r. Be sure “Frame” line on template lines
up with the top edge of doo
r. Using a square,
project “Closer Projection Line” on section “A”
of template onto frame and use to align and
attach section “B”. Be sure to align bottom
edge of section “B” with edge of frame. Mark,
prep and drill/tap 1/4"-20 holes for connecting
rod shoe and closer body mounting screws.
Remove template and use mounting screws to
install the closer body to the top jamb and the
connecting rod shoe to the door. Closer body
should be oriented so that the speed regulating
valves are toward the hinge stile of door.
A longer connecting
rod is required for
reveals greater
than 4" (102 mm
)
Slide cover over closer body and
secure by tightening screws.
Orient main arm so that the “H”, located on the main
arm, lines up with the flat on the spindle. Press arm
down on spindle and secure with spindle bolt.
Slide connecting rod into forearm
of main arm. Rotate main arm until
connecting rod is at a 90˚ angle to
frame. While holding arm in this
position, tighten down forearm screw.
Door Opening Dimension “A”
To 100
7-1/2
"
(191 mm
)
6"
(152 mm
)
4-1/2
"
(114 mm
)
101 to 13
0
131 to *18
0
*Door/Wall/Hardware/Jamb
conditions permitting
Speed regulating valves toward hinge edge
5200 Series Door Closer - Top Jamb Arm
Installation Instruction
s
I-CL00187 R2
5
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 • Fax (800) 782-0149
Reveal
FRAME
WHEN ASSEMBLING TO SPINDLE
POSITION OF MAIN AR
M
RIGHT HAND DOO
R
90
RIGH
T
ANGL
E
PINION FLAT
See Adjustments on Page 6
for setting Spring Power,
Sweep Speed, Latch Speed,
and Backcheck.
NOTE: Do not fully unscrew valves or
hydraulic fluid will leak and closer will no
longer be functional
.
6. OPTIONAL HOLD-OPEN ARM
Identify direction of hold-open nut according to hand of
door and mount arm.
Adjust by loosening hold-open nut, then open door to
desired position and tighten hold-open nut securely.
LH RH
L
S
L
S
ADJUSTMENTS (USE 5/32" HEX WRENCH FOR THESE ADJUSTMENTS)
SPRING
POWER ADJUST (Sizing in accordance to BHMA/ANSI 156.4)
ARM
PLACEMENT IN SHOE
SWEEP
SPEED
5200 Series Door Closer - Adjustments
Installation Instruction
s
I-CL00187 R2
6
HAGER COMPANIES 139 Victor Street, St. Louis, MO 63104 (800) 325-9995 • Fax (800) 782-0149
(Use 5/32" Hex Wrench
for this adjustment)
Adjust latch speed so door
completely closes and latches.
Adjust backcheck accordingly
to prevent excessive opening
speed.
Note: Adjust closing time speed
to between 3 and 7 seconds
from 90˚ to 0˚. Greater closing
times may be required for
elderly or handicapped.
TABLE OF SIZES
Closer is shipped set to size
3. To change the closer size,
use a hex wrench to rotate
th
e spring power adjust.
Follow the chart to make the
correct numbers of 36
turns to set the closer size
appropriately for the door
application.
The
number of turns is an
approximation
and does not
account for environmental or
door hardware affects.
Approx. 5 turns to
increase/decrease one size.
cw = clockwise
ccw = counterclockwise
7-1/2% Stronger
7-1/2%
Weaker
or
or
OPTIONAL DELAY ACTION
Adjust delay action accordingly to
obtain desired delay time.
L
S
ADJUSTMENT DIAGRAM
Y
A
L
E
D
LATCH SPEED
BACKCHECK
Interior Door Width
24"
(610 mm)
30"
(762 mm)
34"
(865 mm)
38"
(965 mm)
48"
(1219 mm)
54"
(1372 mm)
Size 2
(4ccw)
Size 3
(0)
Size 4
(4cw)
Size 5
(8cw)
Size 6
(12cw)
Size 5
(12cw)
Size 1
(4ccw)
Size 1
(8ccw)
Size 2
(0)
Size 3
(4cw)
Size 4
(8cw)
Exterior (and Vestibule) Door Width
24"
(610 mm)
30"
(762 mm)
36"
(914 mm)
42"
(1067 mm)
48"
(1219 mm)
Size 3
(0)
Size 4
(4cw)
Size 4
(8cw)
Size 5
(8cw)
Size 6
(12cw)
Size 5
(12cw)
Size 3
(4cw)
Regular Arm &
Top Jamb
Parallel
Arm
Regular
Arm &
Top Jamb
Parallel
Arm
Minimum Door Width (24")
Minimum Door Width (24")
- - - -
- - - - -
60"
(1524 mm)
-
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6

Hagerco 5200 Series - Grade 1 Heavy Duty - Door Closer Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI