CAME MI Installation guide

Type
Installation guide
SIPA29
WIRELESS KEYPAD
INSTALLATION
MANUAL AND USER
INSTRUCTIONS
En
g
lis
h
EN
119PW08EN
1
2 3
5
4
62 mm 25 mm
120 mm
6
IP 54
ABS
III
±10 m
1 X CR2032
3 V DC/CC
868.032 MHz
75 g
-20°C 55°C
The data and information provided in this manual are subject to change at any time without prior notice.
Page 2 - Manual code:
119PW08
119 PW0 8 vers.
2
2 06/2013 © CAME cancelli automatici S.p.A.
EN
20 mm
Ø5 mm
82 mm
ON
2
1345
ZP11
Page 3 - Manual code:
119PW08
119 PW0 8 vers.
2
2 06/2013 © CAME cancelli automatici S.p.A.
The data and information provided in this manual are subject to change at any time without prior notice.
EN
The data and information provided in this manual are subject to change at any time without prior notice.
Page 4 - Manual code:
119PW08
119 PW0 8 vers.
2
2 06/2013 © CAME cancelli automatici S.p.A.
EN
Wireless keypad
Wireless, battery-powered keypad with password, complete with illumina-
ted and acoustic indicators.
Dimensions
Technical data
Description of the components
1) Rear half-shell 2) Board
3) Front half-shell with membrane keypad
4) Fixing screw 5) Cover 6) Battery.
Installation
Before registration, make sure that the SIPA05 article (see relative
instruction sheet) is inserted in the ZP11 board.
Register the SIPA29 on the Sipario (point 4 master password).
Check the radio signal (point 5 master password).
Do not install on metal components.
Reset the rear half-shell on the wall and drill in three points.
Secure the rear half-shell to the wall.
Attach the front half-shell to the rear half-shell.
Secure the front half-shell using the screw supplied.
Insert and secure the cover, pressing on the sides.
Description of the buttons and operating modes
A keypad off, press any key to activate it; you will hear 1 short
beep to confirm.
If the battery is flat, 6 short beeps will be emitted.
AUTOMATIC: leaf opening with detection device (radar) and auto-
matic closing.
OPENING: leaves open, all detection devices disabled.
CLOSING
: leaves closed, all detection devices disabled.
PARTIAL: partial opening of the leaf up to max 99% of the total run.
EXIT ONLY: leaf opening with internal detection device (radar) and
automatic closing.
ENTER: confirmation key.
BATTERY (Sipario door): enables the battery function in the event
of a power failure.
If the function is enabled, the LED associated with the function
key remains lit.
Master and user passwords
There are two passwords for the keypad: a master password for the
installation technicians and a user password for the end user. Both are
memorised on the keypad only.
Master password: this may be a combination of between 2 and 8
digits. The default password is: 555.
User password: this may be empty or a combination of between 2
and 8 digits.
The default user password is nothing.
The two passwords MUST NOT BE THE SAME.
Page 5 - Manual code:
119PW08
119 PW0 8 vers.
2
2 06/2013 © CAME cancelli automatici S.p.A.
The data and information provided in this manual are subject to change at any time without prior notice.
EN
Master password
The master password is used to:
1. Change the master password.
- Enter the master password (the default password is 555)
and press . The keypad will emit 1 long beep to confirm.
- Press and then .
- Enter the new password and press . The keypad will emit 1 long
beep.
2. Change the user password.
- Enter the master password (the default password is 555)
and press . The keypad will emit 1 beep to confirm.
- Press and then .
- Enter the new password and press . The keypad will emit 1 long beep.
3. Change the keypad ID.
- When installing two keypads with the same default ID, the ID may be
(default) or (to be allocated when installing the second keypad).
The operations described below must be performed on both
keypads:
- Enter the master password and press .
The keypad will emit 1 long beep.
- Press and then .
- The keypad ID will flash.
- If the two IDs are the same, change one by selecting or and
then .
- The keypad will emit 1 long beep to confirm that the ID has been
changed.
4. Registration.
- Set dipswitch 4 to ON on the ZP11 board.
- Enter the master password and press .
The keypad will emit 1 long beep to confirm.
- Press to select the device registration function and press .
- The indicator lights and will flash alternately.
- Once registration is complete, 1 long beep will be emitted and the
indicator light will come on.
- Move dipswitch 4 to the off POSITION.
5. Checking the radio signal.
- Enter the master password and press .
The keypad will emit 1 long beep to show that the password has been
entered correctly.
- Press to select the radio signal checking function and confirm using .
For 30 seconds, or until any key is pressed, the device will check the
radio channel. The result of the check is shown by the flashing of one of
the keys: if the key flashes, the signal is strong. If the key flashes,
the signal is weak. If the key flashes, the signal is missing.
User password.
The user password is used to:
1. Choose an operating mode.
Enter the user password and press .
The data and information provided in this manual are subject to change at any time without prior notice.
Page 6 - Manual code:
119PW08
119 PW0 8 vers.
2
2 06/2013 © CAME cancelli automatici S.p.A.
EN
Press even if no password is set.
The keypad will emit 1 long beep to confirm.
Within 5 seconds, you can select the operating mode required including
the door battery function .
Once the 5 seconds are up, the keypad will emit 1 short beep. The
procedure must be repeated.
2. Change the user password.
Use the following procedure:
Enter the user password;
If the password is nothing, move on directly to point .
Press for 5 seconds.
If the password has been entered correctly, the keypad will emit 1 long
beep and then 3 shorter beeps after 5 seconds.
- Enter the new password and press .
The keypad will emit 1 long beep.
3. Delete the password.
- Enter the user password.
- Press for 5 seconds.
- Press again.
Resetting the default master password and
deleting SIPA29 registration
- Remove the battery from the keypad.
- Press any key.
- Replace the battery.
Proceed as follows within 60 seconds:
- Press any key to activate the selector.
- Press 3 times (3x5);
- Press 3 times (3x3);
- Press 3 times (3x1);
- Press to confirm.
The keypad will emit 1 long beep to confirm the reset.
The procedure for deleting the master password and setting it
back to the default one (555) deletes the registration on the ZP11
board but keeps the user password set.
Error alert
Incorrect password:
5 flashes of all keys and 5 beeps.
Invalid password:
5 flashes of keys - - and 5 beeps.
Incorrect password length:
5 flashes of keys - - and 5 beeps.
Block due to incorrect password:
If the incorrect password is entered 5 times in a row, the keypad will be
blocked for 120 seconds. All the keys lit for 2 seconds and 1 long beep.
Registration:
5 flashes of keys - and 5 beeps.
Communication:
Flashes of keys --- and 5 beeps.
Page 7 - Manual code:
119PW08
119 PW0 8 vers.
2
2 06/2013 © CAME cancelli automatici S.p.A.
The data and information provided in this manual are subject to change at any time without prior notice.
EN
Keypad not registered:
If no door is registered, keys --- remain lit.
Installing the second SIPA29
Change the ID of the second keypad (point 3 master password).
Register the second keypad (point 4 master password).
Replacing SIPA29
- Enter the same ID in the new SIPA29 (point 3 master password).
- Press the reset key on the Sipario's ZP11 board and, within 60
seconds, memorise the new selector (point 4 master password).
Replacing the batteries
If, when the SIPA29 is switched on, 6 beeps are emitted, the battery
must be replaced.
Replace with the same type or an equivalent type of battery
only. Risk of explosion if not replaced correctly.
Keep the batteries out of reach of children. If they are swallo-
wed, contact a doctor immediately.
Dispose of the used batteries in compliance with applicable legislation.
Declaration of conformity
Declaration - Came Cancelli Automatici S.p.A. declares that this
device complies with the essential requirements and other
relevant provisions established in Directives 2014/30/UE/CE,
2006/95/CE, 1999/5/CE.
Reference code for requesting a true copy: DDC RA Q002.
Decommissioning and disposal - Before proceeding, it is always advi-
sable to check specific regulations in force in the place of disposal.
Packaging components (cardboard, plastic etc) can be disposed of to-
gether with normal household waste without any difficulty, by simply
separating the different types of waste and recycling them.
Other components (circuit boards, transmitter batteries etc.), on the
other hand, may contain pollutants. They should therefore be removed
and handed over to companies authorised to recover and recycle them.
DISPOSE OF PROPERLY!
CAME Cancelli Automatici S.p.a.
CAME Cancelli Automatici S.p.a.
Via Martiri Della Libertà, 15
31030
Dosson Di Casier
Dosson Di Casier (Tv)
(+39) 0422 4940
(+39) 0422 4941
Assistenza Tecnica/Numero Verde 800 295830
Assistenza Tecnica/Numero Verde 800 295830
www. came.com
www. came.com
For any other information about the company, products and service in your language:
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

CAME MI Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI