GSS PDP 900 Assembly Instructions

  • Hello! I am an AI chatbot trained to assist you with the GSS PDP 900 Assembly Instructions. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
English
CLASS
KLASSE
PDP 900
Multiswitch Power Pack
GSS
Grundig SAT Systems GmbH
Beuthener Strasse 43
D-90471 Nuremberg
Phone: +49 (0) 911 / 703 8877
Fax: +49 (0) 911 / 703 9210
Internet: http://www.gss.de
- 2 - PDP 900
1 Important information on the safety and assembly
• Assemblyandservicingshouldbecarriedoutbyelectricians.
• Checkthesystemforshortcircuitsinthecoaxialcablesbeforestartingup.
• Onlyinstallthesystemwhenitisnotconnectedtothemainssupply(230V).
• Mountthepowerpackandthemultiswitches…
- onanon-flammablebackground(wall),
- inadust-free,dryenvironment,
-
insuchamannerthatitisprotectedfrommoisture,fumes,splashingwater
anddampness,
- somewhereprotectedfromdirectsunlight,
- notwithintheimmediatevicinityofheatsources,
• Ensurethatthesystemisadequatelyventilated.
Donotcovertheventilationslots!
• Bewareofshortcircuits!
• Noliabilityisacceptedforanydamagecausedbyfaultyconnectionsor
inappropriatehandling.
•
Observe the relevant standards, regulations and guidelines
(IEC/EN/
DINEN60065etc.).
Electronic devices should never be disposed of in the household rubbish. In
accordance with directive 2002/96/EC of the European Parliament and the
European Council from January 27, 2003 which addresses old electronic and
electrical devices, such devices must be disposed of at a designated collection
facility. At the end of its service life, please take your device to one of these
public collection facilities for proper disposal.
2 Technical description
Thepowerpackisonlyusedinconjunctionwiththecascadedmultiswitchesof
aSATreceiversystemtosupplypowertotheconnectedLNBs.
ThepowersupplytotheLNBscomesfromtheSAT-IFinputsofthemultiswitch-
es.Cascadedmultiswitchesonlyneedonepowerpack,whichcanbefittedto
anymultiswitch.TheSAT-IFinputsandoutputsareD.C.coupled.Thiscarries
thevoltagetoalltheSAT-IFlines.
- 3 - PDP 900
3 Assembly
• Unscrewthe2screwsAatthePDC….
• ConnecttheDCoutput(+18VDCOUT)ofthepowerpacktotheDCinput
(+18VDCIN)ofthePDC….
A
A
+18V DC
IN
+18V DC
OUT
• Screwthepowerpacktightlywiththe2screwsA.
A
Power LED
Ventilation openings
Ventilation openings
• Tighten4screwsB.
B
4 Specification
PDP 900
Mainsvoltage
100-230VAC,50/60Hz
Outputvoltage
18VDC
Max.outputcurrent
1000mADC
Ambienttemperature
-20°C…+50°C
Dimensions(WxHxD)[mm]approx.
70x133x55
Service:
Phone:+49(0)911/7032221•Fax:+49(0)911/7032326•Email:ser[email protected]
GrundigSATSystemsGmbH•BeuthenerStraße43•D-90471Nürnberg
Alterations reserved. Technical data E. & O.E. © by GSS GmbH 08062010
/