GSS PDP 900 Assembly Instructions

Type
Assembly Instructions

GSS PDP 900: This power pack is designed for use with cascaded multiswitches in a SAT receiver system. It provides power to the connected LNBs, eliminating the need for a separate power supply for each LNB. The power pack's SAT-IF inputs and outputs are D.C. coupled, allowing voltage to be carried to all SAT-IF lines. The device features a compact design and is easy to install, making it a convenient solution for powering LNBs in a multiswitch system.

GSS PDP 900: This power pack is designed for use with cascaded multiswitches in a SAT receiver system. It provides power to the connected LNBs, eliminating the need for a separate power supply for each LNB. The power pack's SAT-IF inputs and outputs are D.C. coupled, allowing voltage to be carried to all SAT-IF lines. The device features a compact design and is easy to install, making it a convenient solution for powering LNBs in a multiswitch system.

English
CLASS
KLASSE
PDP 900
Multiswitch Power Pack
GSS
Grundig SAT Systems GmbH
Beuthener Strasse 43
D-90471 Nuremberg
Phone: +49 (0) 911 / 703 8877
Fax: +49 (0) 911 / 703 9210
Internet: http://www.gss.de
- 2 - PDP 900
1 Important information on the safety and assembly
• Assemblyandservicingshouldbecarriedoutbyelectricians.
• Checkthesystemforshortcircuitsinthecoaxialcablesbeforestartingup.
• Onlyinstallthesystemwhenitisnotconnectedtothemainssupply(230V).
• Mountthepowerpackandthemultiswitches…
- onanon-flammablebackground(wall),
- inadust-free,dryenvironment,
-
insuchamannerthatitisprotectedfrommoisture,fumes,splashingwater
anddampness,
- somewhereprotectedfromdirectsunlight,
- notwithintheimmediatevicinityofheatsources,
• Ensurethatthesystemisadequatelyventilated.
Donotcovertheventilationslots!
• Bewareofshortcircuits!
• Noliabilityisacceptedforanydamagecausedbyfaultyconnectionsor
inappropriatehandling.
•
Observe the relevant standards, regulations and guidelines
(IEC/EN/
DINEN60065etc.).
Electronic devices should never be disposed of in the household rubbish. In
accordance with directive 2002/96/EC of the European Parliament and the
European Council from January 27, 2003 which addresses old electronic and
electrical devices, such devices must be disposed of at a designated collection
facility. At the end of its service life, please take your device to one of these
public collection facilities for proper disposal.
2 Technical description
Thepowerpackisonlyusedinconjunctionwiththecascadedmultiswitchesof
aSATreceiversystemtosupplypowertotheconnectedLNBs.
ThepowersupplytotheLNBscomesfromtheSAT-IFinputsofthemultiswitch-
es.Cascadedmultiswitchesonlyneedonepowerpack,whichcanbefittedto
anymultiswitch.TheSAT-IFinputsandoutputsareD.C.coupled.Thiscarries
thevoltagetoalltheSAT-IFlines.
- 3 - PDP 900
3 Assembly
• Unscrewthe2screwsAatthePDC….
• ConnecttheDCoutput(+18VDCOUT)ofthepowerpacktotheDCinput
(+18VDCIN)ofthePDC….
A
A
+18V DC
IN
+18V DC
OUT
• Screwthepowerpacktightlywiththe2screwsA.
A
Power LED
Ventilation openings
Ventilation openings
• Tighten4screwsB.
B
4 Specification
PDP 900
Mainsvoltage
100-230VAC,50/60Hz
Outputvoltage
18VDC
Max.outputcurrent
1000mADC
Ambienttemperature
-20°C…+50°C
Dimensions(WxHxD)[mm]approx.
70x133x55
Service:
Phone:+49(0)911/7032221•Fax:+49(0)911/7032326•Email:ser[email protected]
GrundigSATSystemsGmbH•BeuthenerStraße43•D-90471Nürnberg
Alterations reserved. Technical data E. & O.E. © by GSS GmbH 08062010
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

GSS PDP 900 Assembly Instructions

Type
Assembly Instructions

GSS PDP 900: This power pack is designed for use with cascaded multiswitches in a SAT receiver system. It provides power to the connected LNBs, eliminating the need for a separate power supply for each LNB. The power pack's SAT-IF inputs and outputs are D.C. coupled, allowing voltage to be carried to all SAT-IF lines. The device features a compact design and is easy to install, making it a convenient solution for powering LNBs in a multiswitch system.