Whirlpool AKR 679 IX Program Chart

Category
Cooker hoods
Type
Program Chart
5019 318
33115
AKR 651-679-956-963-987-991
INSTALLATIONSANGABEN
Mindestabstand zur Kochfläche: 60 cm (Elektrokochplatten), 75 cm (Gas-, Öl- oder
Kohlekochplatten). Folgen Sie bei der Installation der Nummerierung (1
Ö
2
Ö
3
Ö
.....).
Schließen Sie das Gerät erst nach erfolgter Installation an die Stromversorgung an.
INSTALLATION SHEET
Minimum height above cooker: 60 cm (electric cookers), 75 cm (gas, gas oil or coal
cookers). To install follow points (1
Ö
2
Ö
3
Ö
.....). Do not connect the appliance to the
electrical power supply until installation is completed.
FICHE D’INSTALLATION
Distance minimale par rapport à la cuisinière: 60 cm (cuisinière électrique), 75 cm
(cuisinière à gaz, mazout ou charbon). Pour le montage, suivez la numérotation
(1
Ö
2
Ö
3
Ö
.....). Ne branchez pas l’appareil tant que l’installation n’est pas terminée.
INSTALLATIEKAART
Minimumafstand tot het kooktoestel: 60 cm (elektrische kooktoestellen), 75 cm
(kooktoestellen op gas, olie of kolen). Volg voor de montage de nummering
(1
Ö
2
Ö
3
Ö
.....). Geef het apparaat geen stroom totdat de installatie geheel voltooid is.
FICHA DE INSTALACIÓN
Distancia mínima desde los quemadores: 60 cm (quemadores eléctricos), 75 cm
(quemadores de gas, gasóleo o carbón). Para el montaje, siga la numeración
(1
Ö
2
Ö
3
Ö
...). No enchufe el aparato hasta que su instalación no esté terminada.
FICHA DE INSTALAÇÃO
Distância mínima dos fogões: 60 cm (fogões eléctricos), 75 cm (fogões a gás, óleo ou
carbono). Para montar siga a numeração (1
Ö
2
Ö
3
Ö
.....). Não ligue o aparelho à
corrente eléctrica até a instalação estar concluída.
SCHEDA INSTALLAZIONE
Distanza minima dai fuochi: 60 cm (fuochi elettrici), 75 cm (fuochi a gas, gasolio o
carbone). Per il montaggio seguire la numerazione (1
Ö
2
Ö
3
Ö
.....). Non dare corrente
all’apparecchio finchè l’installazione non è totalmente completata.
ùüùü+ùùùþ
ü$12.)12.1.)2"0120"FP02!"0120"FP0120"
.0! #02!0. #0! # +.22  21.  #1202
.!1
Ö
Ö
Ö
2! 3 / 2020002!)!0*.21#10#!
2  !&12"0.212.1"
D
GB
F
NL
E
P
I
*5
31833115.fm Page 1 Wednesday, December 24, 2003 12:47 PM
5019 318
33115
AKR 651-679-956-963-987-991
R
T
Y
Y
Y
Y
R
T
!
S
U
1
2
V
Z
W
31833115.fm Page 2 Wednesday, December 24, 2003 12:47 PM
5019 318
33115
AKR 651-679-956-963-987-991
31833115.fm Page 3 Wednesday, December 24, 2003 12:47 PM
5019 318
33115
AKR 651-679-956-963-987-991
Assembly - Fig. 1-2-3-4
In order to facilitate installation of the hood and flue support, trace a centre line on the wall between the
hob and ceiling (
Z
).
Position the template against the wall, then mark and drill the holes where indicated (
Y
).
Insert two wall plugs with hooks (
V
).
Hang the hood and adjust the position by turning the adjustment screws (
S
).
Remove the grease filters and mark the holes for secure fixing (
T-R
).
Remove the hood and drill the holes (4 x Ø 8 mm).
Insert 4 wall plugs and two screws in the top holes: they will ensure secure fixing (
X
).
Fix the flue support (
Z
) as close as possible to the ceiling with two screws and wall plugs.
Important! Check that the support is perfectly aligned with the hood.
Rehang the hood on the wall.
Fix the hood with two screws at the bottom (
D
).
Installing the exhaust pipe (Extractor version)
Warning! The exhaust pipe and clamps are not supplied and must be bought separately.
Connect one end of the exhaust pipe (
J
) to the hood (
G
) with the other end directed to the outside.
Installing the deflector (Filter version)
Fix the deflector (
F
) to the flue support with 4 screws.
Connect the deflector to the hood with an exhaust pipe.
Warning! The exhaust pipe and clamps are not supplied and must be bought separately.
Installing the electronic box
Some models require the installation of a box containing the electronic board that controls hood functions
(see list of models indicated in
Fig. 4
in the first pages of this booklet).
Simply snap fit the electronic box
S2
in place
S1
and secure it with a screw.
Installing the telescopic flue
Connect the hood to the power supply.
Fix the telescopic flue (
M
) to the support (
Z
) with two screws and let it slide down to its specific seat on
the top of the hood
D F NL E
GB
P I GR
31833115.fm Page 7 Wednesday, December 24, 2003 12:47 PM
5019 318
33115
AKR 651-679-956-963-987-991
1.
Control panel.
2.
Grease filters.
3.
Lighting unit (AKR 679-963 - halogen bulbs).
4.
Telescopic flue.
5.
Grease filter release-replace handle.
Removing and renewing or washing the
grease filter
1.
Disconnect the electrical power supply.
2.
Remove the grease (
Fig. 6
):
a
- push the handles backwards
b
- then downwards.
3.
After the grease filter has been replaced or
cleaned (depending on model), refit the parts in
reverse order, making sure the entire extraction
surface is covered.
Replacing bulbs
1.
Disconnect the electrical power supply.
2.
Open the extractor grille or remove the self-
supporting grease filter (depending on model).
Fig. 6 (a-b)
.
3.
Remove the burnt-out bulb.
Replace using 40W max E14 bulbs only.
4.
Refit the extractor grille or grease filter.
Only for model equipped with halogen bulbs
Use a small screwdriver or any other suitable tool to
prise off
(m-Fig. 7)
the lamp cover
(p-Fig. 7).
Replace the damaged bulb.
Use 20W max halogen bulbs only, making sure not to
touch them with your hands. Close the lighting unit
(snap-close).
Fitting or renewing the carbon filter - Fig. 8:
1.
Disconnect the electrical power supply.
2.
Remove the grease filters.
3.
If the filters are not already fitted, locate one on
each side to cover both motor protection grilles,
check that pins
R
on the duct align with slots
S
,
then turn it clockwise until it locks.
4.
To remove the carbon filter, proceed in reverse
order.
5.
Replace the grease filters.
CONTROL PANEL
(Switches or buttons)
Light switch/Button
The switch/button has two positions. To switch
on the lights: move the switch to the right (model
with switches) or press the button (model with
buttons).
Extraction speed selection Switch/Buttons
There are different extraction speed settings,
depending on the amount of steam and fumes.
To increase the extraction speed: move the
switch, or next button to the right
.
Fig. 5
4
2
3
3
1
a
b
R
R
S
S
Fig. 6
Fig. 7
Fig. 8
D F NL E
GB
P I GR
PRODUCT SHEET
31833115.fm Page 8 Wednesday, December 24, 2003 12:47 PM
1 / 1

Whirlpool AKR 679 IX Program Chart

Category
Cooker hoods
Type
Program Chart

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI

Ask the document