Super Bright LEDS XS2-R is a versatile LED exit sign designed for indoor use with a variety of mounting options for top or side mounting and rear wall mount installations. It features a durable construction with a lightweight 2.4 lb body and operates within a temperature range of 32°–104° F (0°–40° C). The XS2-R provides clear and efficient "EXIT" signage, adhering to safety regulations and illuminating pathways during emergencies.

Super Bright LEDS XS2-R is a versatile LED exit sign designed for indoor use with a variety of mounting options for top or side mounting and rear wall mount installations. It features a durable construction with a lightweight 2.4 lb body and operates within a temperature range of 32°–104° F (0°–40° C). The XS2-R provides clear and efficient "EXIT" signage, adhering to safety regulations and illuminating pathways during emergencies.

LED Exit Sign
XS2 Series
4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com
Specications
Converting for Dual-Sided Operation
XS2-R
Operating Temperature 32°–104° F (0°–40° C)
Fixture Weight 2.4 lb (1.1 kg)
User Manual
XS2-R
¹
¹Limited 2-year warranty on battery.
Rev Date: V1 05/07/2021
Wiring Diagram
Important: Read all instructions prior to installation. SAVE THESE INSTRUCTIONS.
Safety Instructions
Read and follow all safety instructions. When using electrical
equipment, basic safety precautions should always be
followed including the following:
All wiring should be performed by a qualied electrician.
Disconnect power before installing or servicing. This xture
must be wired in accordance with the National Electical
Code and applicable to local codes and ordinances.
Proper grounding is required to ensure personal safety.
Do NOT use this equipment for other than its intended use.
WARNING: Make certain power is OFF before installing or
maintaining xture. No user serviceable parts inside.
WARNING: When re-lamping, only use lamps specied
in the exit sign. Using other lamp types may result in
transformer damage or unsafe conditions
WARNING: Battery in this unit may not be fully charged.
After electricity is hooked up to the unit, let the battery
charge for at least 24 hours. Then normal operation of this
unit should take eect (when applicable).
WARNING: Equipment should be mounted in locations
and at heights where it will not be subject to tampering by
unauthorized personnel. Flexible conduit only.
WARNING: do NOT use outdoors.
WARNING: do NOT mount near gas or electric heaters.
1. Carefully remove the blank panel using a at-head
screwdriver to release tabs.
2. Install additional “exit” panel in place of the removed panel.
Check product label for specific electrical
specifications related to installation.
Improper installation will void warranty.
277 VAC(RED)
COMM(WHITE)
120 VAC (BLACK)
AC input
Battery
TEST
AC ON
Fixture Housing
Mounting Bracket
Crossbar Bracket
Junction Box
Fixture Housing
Mounting Bracket
Crossbar Bracket
Junction Box
Fixture Housing
Crossbar Bracket
Junction Box
Top or Side Mounting Installation
4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com
LED Exit Sign
Important: Read all instructions prior to installation. XS2 Series
User Manual
¹
¹Limited 2-year warranty on battery.
Rev Date: V1 05/07/2021
1. Turn o supply power.
2. Carefully remove one of the panels using a at-
head screwdriver to release tabs.
Note: If the unit will need both sides to use “exit
panels, the blank panel should be removed for this
step.
3. Run wiring through mounting bracket, then attach
mounting bracket to light.
4. Install crossbar bracket on junction box.
5. Connect wiring to junction box, corresponding to
voltage. Cap unused wire.
Note: Red and black wires should never be
connected at the same time.
6. Securely attach to crossbar/junction box.
7. Connect battery to board.
8. Reinstall panel and install directional arrow covers
as needed.
9. Turn on AC supply and allow battery pack to
charge for at least 24 hours before initial test.
10. After 24-hour period, press test button to make
certain light is functioning as intended.
Fixture Housing
Mounting Bracket
Crossbar Bracket
Junction Box
Fixture Housing
Mounting Bracket
Crossbar Bracket
Junction Box
Fixture Housing
Crossbar Bracket
Junction Box
Rear Wall Mount Installation
4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com
LED Exit Sign
Important: Read all instructions prior to installation. XS2 Series
User Manual
¹
¹Limited 2-year warranty on battery.
Rev Date: V1 05/07/2021
1. Turn o supply power.
2. Carefully remove “exit” panel using a at-
head screwdriver to release tabs.
3. Create holes in the blank panel for wiring
and mounting in blank panel.
4. Connect wiring to junction box,
corresponding to voltage. Cap unused wire.
Note: Red and black wires should never be
connected at the same time.
5. Mount to junction box/surface.
6. Reinstall “exit” panel, and install directional
arrow covers as needed.
7. Turn on AC supply and allow battery pack to
charge for at least 24 hours before initial use.
8. After 24-hour period, press test button to
make certain light is functioning as intended.
Fixture Housing
Mounting Bracket
Crossbar Bracket
Junction Box
Fixture Housing
Mounting Bracket
Crossbar Bracket
Junction Box
Fixture Housing
Crossbar Bracket
Junction Box
  • Page 1 1
  • Page 2 2
  • Page 3 3

Super Bright LEDS XS2-R User manual

Type
User manual

Super Bright LEDS XS2-R is a versatile LED exit sign designed for indoor use with a variety of mounting options for top or side mounting and rear wall mount installations. It features a durable construction with a lightweight 2.4 lb body and operates within a temperature range of 32°–104° F (0°–40° C). The XS2-R provides clear and efficient "EXIT" signage, adhering to safety regulations and illuminating pathways during emergencies.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI