VTAJ-50K20-x

Super Bright LEDS VTAJ-50K20-x User manual

  • Hello! I've reviewed the user manual for the superbrightleds VTAJ Series VTAJ-50K20-x Vapor-Proof Jelly Jar Light. This document provides detailed installation instructions for both surface mounting and conduit mounting, as well as safety guidelines. It also includes important specifications such as the operating temperature and IP rating. I'm ready to answer any questions you have about this device.
  • What is the operating temperature range for this light?
    What is the IP rating of the light?
    What are the two installation methods?
Vapor-Proof Jelly Jar Lights
User Manual
Important: Read all instructions prior to installation. VTAJ Series
4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com
Rev Date: V2 01/11/2022
Specications
Wiring Diagram
Exploded View
Model VTAJ-50K20-x
Operating Temperature -40°–113° F (-40°–45° C)
IP Rating IP65
Safety and Notes
Installation
Product should be installed by a certied electrician in
accordance with applicable national, state, and local
building and electrical codes.
To reduce risk of electric shock, ensure main power source
and circuit breakers are switched o before performing any
installation or wiring procedures.
Ensure all mounts are securely attached and will support
weight of xture. Failure to properly support xture may
result in damage or injury, for which the manufacturer does
not assume responsibility.
Surface Mount
1. Remove junction box section.
2. Apply supplied gasket or silicone compound (WFLS-GL1OZ
or equivalent) to back of junction box and attach to surface.
3. Connect wires according to wiring diagram.
4. Reattach xture to junction box using supplied gasket.
Mounting Using Junction Box Conduit NPT Knockouts
1. Remove junction box section.
2. Remove 3/4” plug from intended direction of conduit feed. Apply
supplied gasket or silicone compound (WFLS-GL1OZ
or equivalent) to back of junction box and attach to wall.
3. Feed conduit into junction box. Apply silicone compound (WFLS-
GL1OZ or equivalent) to areas where conduit and junction box
meet to create seal.
4. Connect wires according to wiring diagram.
5. Reattach xture to junction box using supplied gasket.
Line
Neutral
Ground
Black
L L
N N
GND GND
White
Dim (+)
Dim (-)
Purple
+ +
- -
Gray
Green
Check product label for specific electrical
specifications related to installation.
Improper installation will void warranty.
4.88in
124.07mm
3.85in
97.79mm
6.46in
164.19mm
5.02in
127.51mm
5.00in
127mm
WIRES
4.18in
106.30mm
10.00in
254.08mm
12.125in
307.97mm
90°
3/4 THREADED CONDUIT
POSITION LOCK NUT
GASKET
/