superbrightleds com LPD Series User manual

Type
User manual
LED Dimmable Panel Light
Important: Read all instructions prior to installation. LPD Series
4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com
Rev Date: V2.0 10/27/2021
User Manual
7yr
Recessed Installation
Wiring Diagram
Mounting Options
Safety and Notes
LPD-xK24-40 LPD-xK22-40 LPD-xK14-40
Operating Temperature -4°–104° F (-20°40° C)
IP Rating IP20
Weight 16 lb 5oz (7.4 kg) 8 lb 2oz (3.7 kg) 8 lb 12oz (4 kg)
Product should be installed and serviced by a certied
electrician in accordance with applicable national, state, and
local building and electrical codes.
To reduce the risk of electric shock, ensure that the main power
source and circuit breakers are switched o before performing
any installation or wiring procedures.
Avoid looking directly into lamp when illuminated.
Ensure all mounts are securely attached and will support the
weight of the xture. Failure to properly support xture may
result in damage or injury, for which the manufacturer does not
assume responsibility.
Specications
Check product label for specific electrical
specifications related to installation.
Improper installation will void warranty.
LPD-40K24-40-SMK
Note: Recessed Mounting Kit
Required (LPD-JBK)
1. Turn off power and remove
existing fixture or remove ceiling tile.
2. Bend each t-bar safety hook away
from panel until facing perpendicular
to panel backing. Bend hook arm
until facing perpendicular to hook
body. (Fig. 2 & 3)
3. Remove the knockout hole on the
junction box. Run wiring through
hole and secure conduit. (Fig. 4)
Connect all wiring according to the
wiring diagram.
4. Attach junction box to panel backing by
inserting the tabs from the junction box into
the slots on the panel backing. Secure to the
panel with provided screw. (Fig. 5)
5. Place panel into T-grid, making sure it is
securely supported.
FS SERIES
Surface Mounted Kit Installation
FS SERIES
Surface Mounted Kit Installation
S tep2: Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6: Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4: Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S te p 1: Remove the surface mounted kit
from the luminaire.
1
S te p5: Fix the metal string on the hook.
(Fig.2)
5
S tep3: Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8: Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S te p7: Put the wire into the J-box.
7-1
8-2
2
RECESSED INST ALLA TION
FS SERIES
FS SERIES INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2page 1 page 4page 3
RECESSED INST ALLA TION
Step3: Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1: Remove the surface mounted kit from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step: Fristly , Turn on to 100% brightness
Secondly ,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness, At last ,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the dimmer+(PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2 Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note: After 3s turn on lamp to 100% brightness.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10%
brightness
Turn On
Lamp
50%
brightness
Turn On
Lamp
100%
brightness
After 0.5S At 0.5-2s
At 0.5-2s
After 0.5S
After 0.5S
Figure7
To r i g h t p o s i ti o n
7-2
1
2
3
4
R ight pos ition
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
LINE
NEUTRAL
GROUND
PURPLE
GREY
BLACK
WHITE
GREEN
LED
PANEL
Dimming
Driver
Recessed Mounting Kit (LPD-JBK)
sold separately
Surface Mounting Kit (LPD-SMK24, LPD-SMK22, LPD-SMK14)
sold separately
1 - Junction Box
1 - Attachment Screw
1 - Surface Mount Bracket
7 - Screws
7 - Screw Anchors
1 - Cable Service Loop
1 - Cable Service Loop Screw
LED Dimmable Panel Light
Important: Read all instructions prior to installation. LPD Series
4400 Earth City Expy, St. Louis, MO 63045 866-590-3533 superbrightleds.com
Rev Date: V2.0 10/27/2021
User Manual
7yr
FS SERIES
Surface Mounted Kit Installation
FS SERIES
Surface Mounted Kit Installation
S tep2: Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6: Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S te p1 : Remove the surface mounted kit
from the luminaire.
1
S te p5: Fix the metal string on the hook.
(Fig.2)
5
S tep3: Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8: Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7 : Put the wire into the J-box.
7-1
8-2
2
RECESSED INST ALLA TION
FS SERIES
FS SERIES INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2page 1 page 4page 3
RECESSED INST ALLA TION
Step3: Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1: Remove the surface mounted kit from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step: Fristly , Turn on to 100% brightness
Secondly ,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness, At last ,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the dimmer+(PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2 Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note: After 3s turn on lamp to 100% brightness.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10%
brightness
Turn On
Lamp
50%
brightness
Turn On
Lamp
100%
brightness
After 0.5S At 0.5-2s
At 0.5-2s
After 0.5S
After 0.5S
Figure7
To r ig h t po s i ti o n
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit Installation
FS SERIES
Surface Mounted Kit Installation
S tep2: Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6: Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S te p1 : Remove the surface mounted kit
from the luminaire.
1
S te p5: Fix the metal string on the hook.
(Fig.2)
5
S tep3: Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8: Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7 : Put the wire into the J-box.
7-1
8-2
2
RECESSED INST ALLA TION
FS SERIES
FS SERIES INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2page 1 page 4page 3
RECESSED INST ALLA TION
Step3: Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1: Remove the surface mounted kit from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step: Fristly , Turn on to 100% brightness
Secondly ,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness, At last ,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the dimmer+(PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2 Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note: After 3s turn on lamp to 100% brightness.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10%
brightness
Turn On
Lamp
50%
brightness
Turn On
Lamp
100%
brightness
After 0.5S At 0.5-2s
At 0.5-2s
After 0.5S
After 0.5S
Figure7
To r ig h t po s i ti o n
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit Installation
FS SERIES
Surface Mounted Kit Installation
S tep2: Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6: Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S te p1 : Remove the surface mounted kit
from the luminaire.
1
S te p5: Fix the metal string on the hook.
(Fig.2)
5
S tep3: Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8: Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7 : Put the wire into the J-box.
7-1
8-2
2
RECESSED INST ALLA TION
FS SERIES
FS SERIES INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2page 1 page 4page 3
RECESSED INST ALLA TION
Step3: Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1: Remove the surface mounted kit from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step: Fristly , Turn on to 100% brightness
Secondly ,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness, At last ,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the dimmer+(PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2 Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note: After 3s turn on lamp to 100% brightness.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10%
brightness
Turn On
Lamp
50%
brightness
Turn On
Lamp
100%
brightness
After 0.5S At 0.5-2s
At 0.5-2s
After 0.5S
After 0.5S
Figure7
To r ig h t po s i ti o n
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit Installation
FS SERIES
Surface Mounted Kit Installation
S tep2: Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6: Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S te p1 : Remove the surface mounted kit
from the luminaire.
1
S te p5: Fix the metal string on the hook.
(Fig.2)
5
S tep3: Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8: Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7 : Put the wire into the J-box.
7-1
8-2
2
RECESSED INST ALLA TION
FS SERIES
FS SERIES INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2page 1 page 4page 3
RECESSED INST ALLA TION
Step3: Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1: Remove the surface mounted kit from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step: Fristly , Turn on to 100% brightness
Secondly ,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness, At last ,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the dimmer+(PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2 Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note: After 3s turn on lamp to 100% brightness.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10%
brightness
Turn On
Lamp
50%
brightness
Turn On
Lamp
100%
brightness
After 0.5S At 0.5-2s
At 0.5-2s
After 0.5S
After 0.5S
Figure7
To r ig h t po s i ti o n
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit Installation
FS SERIES
Surface Mounted Kit Installation
S tep2: Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6: Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S te p1 : Remove the surface mounted kit
from the luminaire.
1
S te p5: Fix the metal string on the hook.
(Fig.2)
5
S tep3: Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8: Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7 : Put the wire into the J-box.
7-1
8-2
2
RECESSED INST ALLA TION
FS SERIES
FS SERIES INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2page 1 page 4page 3
RECESSED INST ALLA TION
Step3: Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1: Remove the surface mounted kit from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step: Fristly , Turn on to 100% brightness
Secondly ,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness, At last ,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the dimmer+(PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2 Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note: After 3s turn on lamp to 100% brightness.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10%
brightness
Turn On
Lamp
50%
brightness
Turn On
Lamp
100%
brightness
After 0.5S At 0.5-2s
At 0.5-2s
After 0.5S
After 0.5S
Figure7
To r ig h t po s i ti o n
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit Installation
FS SERIES
Surface Mounted Kit Installation
S tep 2: Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6: Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S te p1 : Remove the surface mounted kit
from the luminaire.
1
S te p5: Fix the metal string on the hook.
(Fig.2)
5
S tep3: Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8: Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7: Put the wire into the J-box.
7-1
8-2
2
RECESSED INST ALLA TION
FS SERIES
FS SERIES INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2page 1 page 4page 3
RECESSED INST ALLA TION
Step3: Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1: Remove the surface mounted kit from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step: Fristly , Turn on to 100% brightness
Secondly ,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness, At last ,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the dimmer+(PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2 Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note: After 3s turn on lamp to 100% brightness.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10%
brightness
Turn On
Lamp
50%
brightness
Turn On
Lamp
100%
brightness
After 0.5S At 0.5-2s
At 0.5-2s
After 0.5S
After 0.5S
Figure7
To r i g h t p o s i ti o n
7-2
1
2
3
4
R ight pos ition
FS SERIES
Surface Mounted Kit Installation
FS SERIES
Surface Mounted Kit Installation
S tep2: Turn off power. Insert the L,N wires
of the J-box into the male connector.
2
S tep6: Plug the female connector of the
luminaire into the male connector of the AC
input wire.The Ground connects to Green
wire.Dimming wires connect according to
the same wire color.
6
S tep4:Alight the 2 longer hooks on the metal plate with
the longer hole on the luminaire(Look at the metal palte
and the luminaire with the 'STEP 1' mark). Slightly move
the luminaire forward and make sure the hooks is in
right position.
4
S te p1 : Remove the surface mounted kit
from the luminaire.
1
S te p5: Fix the metal string on the hook.
(Fig.2)
5
S tep3: Align the holes on the surface mounted kit with
the hole on the J-box Tighten 2#8-32 screws, rotate
the plate to your right position and lots of KA3.5*20mm
screws into the ceiling and make the kit flush with
the ceiling.
3
Step8: Push the luminaire on the ceiling. Make
sure the 4 hooks are inside the luminaire and
push forward the luminaire until you hear a
clicking sound.
8-1
S tep7 : Put the wire into the J-box.
7-1
8-2
2
RECESSED INST ALLA TION
FS SERIES
FS SERIES INST ALLA TION
Please read this entire manual to fully understand and safely use this product.
Specifications are subject to change without notice.
Please visit our website the most recent user guide versions.
NOTE
Unpack and carefully examine the product.
Report any damage and save all packing materials if any part(s) were damaged during shipping.
Do not attempt to use this apparatus if it is damaged.
UNP ACKING
1
2
3
Designed for use in 100V~277V,50-60Hz protected circuit. Apply class 2 power supply.
READ ALL INSTRUCTIONS BEFORE INST ALLA TION
1
2
3
4
5
6
7
8
Consult a qualified electrician to ensure correct branch circuit conductor.
The product should be installed and operated by a qualified electrician or technician in
with relevant local codes.
accordance
Risk of electric shock. Ensure that main power source is off when wiring or soldering the
of the product.
sections
Before installing this fixture or doing any maintenance, make sure to turn off the power
the circuit breaker or fuse box.
supply at
Check to make sure that all fixture connections have been properly made and the fixture
grounded to avoid potential electrical shocks.
is
Do
in water.
not handle energized fixture when hands are wet, when standing on wet or damp surfaces, or
This
conditions to ensure safety to human body.
panel lights are normally set to work at extra low voltage below DC42V and constant current
OPTIONAL
FS22-DL-XXX, FS22-DM-XXX, FS24-DM-XXX, FS24-DH-XXX,VS14-DM**
Suitable for Damp location . Access above ceiling required. Suitable for suspended ceilings
IMPORT ANT SAFETYINFORMA TION
CAUTION: Risk of Electric Shock
!
Accessory:
LED Luminaire
Installation instruction
Surface mounted kit (for surface mounted)
J-box ( for recessed )
page 2page 1 page 4page 3
RECESSED INST ALLA TION
Step3: Turn off power,remove the ceiling panel. Then place
the panel in to the T-bar,ensure he panel is attached to the
ceiling.
(Figure3)
Step4:
connect conduit to J-box with proper connector(s).
Remove appropriate round knock-out(s) and
Step5:
tightly.the line connect to the connector with the black
mark, the natural connect to another,the ground connect
to the green wire.(Figure4)
Put a connector to the end of AC input wire and
Step1: Remove the surface mounted kit from the luminaire.
Step2:
Same to 4 hang buckles.(Figure 2)
Bend hang buckle by 90° making it vertical to
the rear cover of panel light.
Step7: Push all wires back into the junction box,Close J-BOX for cap (Figure 5).
please use switch to dim and don’t need to connect the dimming
wire. Dimming step: Fristly , Turn on to 100% brightness
Secondly ,It takes about 0.5~2 seconds from turn off the light to
next trun on and lamp is in 50% brightness, At last ,It takes
about 0.5~2 seconds from turn off the light to next trun on and
lamp 10% brightness. (Figure 7)
Note: For cycle of step dimming, wait until the lamp is in brightness.
For failure of step dimming, turn off the lamp and turn on after 3 second.
For Step Dimming
,
For 0-10V Dimming
The driver PUR (D+) to the dimmer+(PUR),and the
driver GRY(D-)to the dimmer-(GRY)
Connect the wires with terminal cap as shown in wiring
diagram (Figure 6).
Incoming insulated dimming conductors shall have
voltage rated at least equal to the branch voltage.
Compatible with 0-10V dimmer
Figure1
Figure2 Figure3
Figure4
Figure5
WIRING DIAGRAM
0-10V
Dimmer
D +
D -
PURPLE
GREY
L
N
G
PURPLE
GREY
RED BLACK
BLACK
WHITE
GROUND
LED
PANEL
Dimming
Driver
Figure6
Step Dimming
One Cycle
Note: After 3s turn on lamp to 100% brightness.
Turn Off
Lamp
Turn Off
Lamp
Turn Off
Lamp
Turn On
Lamp
10%
brightness
Turn On
Lamp
50%
brightness
Turn On
Lamp
100%
brightness
After 0.5S At 0.5-2s
At 0.5-2s
After 0.5S
After 0.5S
Figure7
To r igh t p o s i ti o n
7-2
1
2
3
4
R ight pos ition
1. Turn o power and run supply wiring
through junction box. Connect wiring using
wiring diagram. (Fig. 2)
2. Attach surface mounting bracket to junction
box and align to the desired orientation. Mark
screw holes and drill pilot holes. Remove bracket
and insert screw anchors into mounting surface
at marks. Reinstall bracket to junction box and
install mounting screws. (Fig. 3)
3. Screw steel cable service loop to light
panel (Fig.5). Align the hooks labeled “Step
1” on the surface mounting bracket with
the larger slots along the edge of the panel
backing labeled “Step 1” and slide to lock in
place. (Fig. 4)
4. Attach the steel cable service loop from the
panel to one of the surface mount bracket hooks
to hold the panel while wiring. (Fig. 5)
5. Connect the ground wire. Connect the two
orange quick disconnects together. Connect
the 0–10 V dimming wires according to the
wiring diagram if needed. (Fig. 6)
6. Tuck wiring into junction box, being sure not
to pinch wires. (Fig. 7-1)
7. Lift panel onto remaining hooks on surface
mounting bracket while aligning to remaining
slots on panel. Slide panel to lock into place.
(Fig. 8-1 & 8-2)
Screw
Screw
Surface Mount Kit Installation
  • Page 1 1
  • Page 2 2

superbrightleds com LPD Series User manual

Type
User manual

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI