Instructions
Manitowoc Beverage Systems Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
020004047
11/14
Subject: Selectable Ice ADA Retrofit Installation
These instructions are for installations with this option
and cover the external ADA key pad boxes for the Flavor
Magic features.
TOOLS REQUIRED
• Phillips Head Screwdriver
• Flat Blade Screwdriver
INSTALLATION OF ADA KEY PADS
1 Remove power from the unit.
Merchandiser Removal
2 Gain access to the merchandiser area of the dispenser by one
of the following methods;
A. SV & SVi Series units, loosen the two knurled fasteners
located in the top of the merchandiser that hold the
merchandiser in place. Then remove the merchandiser by
lifting up and tilting forward.
ADA Wire Harness
3 Route the ADA ribbon cable under the drain pan.
4 Continue routing the ADA cable behind the valve mount cap
on the left hand side of the unit.
KIT 020004044 CONTENTS
QTY DESCTRIPTION Part Number
1 Box Control - SCI/FS ADA 020003885
1 Harness SCI ADA 020003893
1 Lever Open Center Long 020003945
1 Label Sheet / ADA Set 020003960
2 Screw #10 X 3/4 Hex HD 00216417
2 Flat Washer 0.281ID X 0.625OD X.062 00850357
1 Wire & Cord Clip 0905403
Electric Shock & Moving Parts Hazard
Unplug unit before servicing.
ADA Box
Ribbon Cable
Drain Pan
ADA Harness
ADA Box
Ribbon Cable
ADA Box
Ribbon Connector