KitchenCare SV & Selectable Ice ADA Retrofit 020004047 Installation guide

Category
Wall & ceiling mounts accessories
Type
Installation guide
Instructions
Manitowoc Beverage Systems Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
020004047
11/14
Subject: Selectable Ice ADA Retrofit Installation
These instructions are for installations with this option
and cover the external ADA key pad boxes for the Flavor
Magic features.
TOOLS REQUIRED
Phillips Head Screwdriver
Flat Blade Screwdriver
INSTALLATION OF ADA KEY PADS
1 Remove power from the unit.
Merchandiser Removal
2 Gain access to the merchandiser area of the dispenser by one
of the following methods;
A. SV & SVi Series units, loosen the two knurled fasteners
located in the top of the merchandiser that hold the
merchandiser in place. Then remove the merchandiser by
lifting up and tilting forward.
ADA Wire Harness
3 Route the ADA ribbon cable under the drain pan.
4 Continue routing the ADA cable behind the valve mount cap
on the left hand side of the unit.
KIT 020004044 CONTENTS
QTY DESCTRIPTION Part Number
1 Box Control - SCI/FS ADA 020003885
1 Harness SCI ADA 020003893
1 Lever Open Center Long 020003945
1 Label Sheet / ADA Set 020003960
2 Screw #10 X 3/4 Hex HD 00216417
2 Flat Washer 0.281ID X 0.625OD X.062 00850357
1 Wire & Cord Clip 0905403
!
Warning
Electric Shock & Moving Parts Hazard
Unplug unit before servicing.
ADA Box
Ribbon Cable
Drain Pan
ADA Harness
ADA Box
Ribbon Cable
ADA Box
Ribbon Connector
Selectable Ice ADA Retrofit Installation 020004047 11/14
Manitowoc Foodservice Sellersburg, 2100 Future Drive, Sellersburg, IN 47172, Tel: 812-246-7000, www.manitowocbeverage.com
5 Connect the ADA ribbon cable to the ADA wire harness
located to the left of the ice chute and held to the foam front by
a wire clip.
6 Neatly tuck in and take up any slack remaining in the ADA
ribbon cable so it will not be in the way of any moving parts or
panels when they are placed back on the unit.
Drain Pan & ADA Touch Pad Box
7 Attach the drain pan to the unit.
8 Center the ADA Key Pad Box with the unit in front of the drain
pan and secure into place.
9 Apply corresponding drink labels to the ADA key pads.
10 Drinks correspond from left to right on the left side of the unit,
and right to left on the right side of the unit. If buttons are not
used they will be blanked out. The Cubed/Crushed buttons are
only utilized on units configured with the Selectable Ice feature.
ADA Key Pad Matrix
Finish Installation
11 Put the splash panel and merchandiser back onto the unit and
reinstall the screws that hold them in place.
12 Restore power to the unit.
Important
If mounting the ADA Box directly in front of the drain pan
on the counter top leave a minimum of 1 inch space
between the bottom edge of the drain pan and the ADA
Box to allow space for drain pan removal.
ADA Box
Ribbon Cable
ADA Harness
ADA Wire
Harness Clip
Connected ADA
Cables
Drain Pan
ADA Box
12345 678910
123 456
Cubed Crushed
Cubed Crushed
6 Valve Dispensers
12345678 910
1234 5678
Cubed Crushed
Cubed Crushed8 Valve Dispensers
12345 678910
12
10 Valve Dispensers
34 5 678910
Cubed Crushed
Cubed Crushed
  • Page 1 1
  • Page 2 2

KitchenCare SV & Selectable Ice ADA Retrofit 020004047 Installation guide

Category
Wall & ceiling mounts accessories
Type
Installation guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI