Skov DA 1800 Ceiling Inlet Mounting Guide

Type
Mounting Guide
DA 1800 CD Ceiling Inlet
Mounting Guide
603882 • 2020-08-28
DA 1800 CD Ceiling Inlet
Mounting Guide 3
Product and Documentation Changes
SKOV A/S reserves the right to change this document and the product herein described without further notice.
In case of doubt, please contact SKOV A/S.
The date of change appears from the front and back pages.
Note
All rights belong to SKOV A/S. No part of this manual may be reproduced in any manner whatsoever without
the expressed written permission of SKOV A/S in each case.
All reasonable efforts have been made to ensure the accuracy of the information contained in this manual.
Should any mistakes or imprecise information occur in spite of this, SKOV A/S would appreciate being noti-
fied thereof.
Irrespective of the above, SKOV A/S shall not accept any liability with regard to loss or damage caused or
alleged to be caused by reliance on any information contained herein.
Copyright by SKOV A/S.
DA 1800 CD Ceiling Inlet
Mounting Guide
1 Product description........................................................................................................................................5
1.1 Principle of application ............................................................................................................. 5
2 Product survey ...............................................................................................................................................6
2.1 Accessories................................................................................................................................ 6
3 Mounting guide...............................................................................................................................................8
3.1 Recommended tools.................................................................................................................. 8
3.2 Placement in ceiling .................................................................................................................. 9
3.3 Preassembly............................................................................................................................... 9
3.4 Mounting lengthwise of boarding ..........................................................................................10
3.5 Mounting across boarding...................................................................................................... 10
3.6 Mounting the string .................................................................................................................10
3.7 Mounting on sloping surfaces................................................................................................ 11
4 Maintenance instructions ............................................................................................................................12
4.1 Recycling/Disposal .................................................................................................................. 12
5 Technical data...............................................................................................................................................13
5.1 Dimensioned sketch ................................................................................................................ 13
DA 1800 CD Ceiling Inlet
Mounting Guide 5
1 Product description
DA 1800 CD ceiling inlet is an efficient and compact fresh air inlet for supplementary ventilation in vapour-per-
meable ceiling constructions. The inlet opens by slackening the string.
The ceiling inlet is made of injection-moulded ABS which is dirt-repellent and easy to clean. The inlet is insu-
lated with polystyrene in the inlet casing. The capacity is high with a max. output of 1800 m3/h at 10 Pa negative
pressure.
The inlet consists of 6 parts, arm for pull rod and string and arm for flap are mounted with screws, while pipe
holder for cooling pipe is clicked into place.
Inlet flap
Arm for flap
Inlet insulation
Inlet funnel
Inlet casing with
insulation
Arm for pull rod
and cord
Pipe holder for
cooling pipe
1.1 Principle of application
During hot periods with high ventilation require-
ments, a large volume of air can be directed
down into the animal zone.
During cold periods, the air is directed through
the ceiling.
DA 1800 CD Ceiling Inlet
6 Mounting Guide
2 Product survey
401361 DA 1800 ceiling inlet CD
DA 1800 ceiling inlet is a universal air inlet, which brings fresh air into the
house through the attic. DA 1800 is insulated and available as standard
with a regulation set.
The inlet funnel must be ordered separately.
2.1 Accessories
401323 DA 1500/1800 inlet funnel - short
401337 DA 1540/1800 inlet funnel - long
The purpose of using the inlet funnel is partly to increase the incorporation
height of the inlet to a total of 250/400 mm from the lower edge of the ceil-
ing to the upper edge of the inlet funnel. Furthermore, the aerodynamic de-
sign of the inlet funnel ensures optimized inflow conditions which reduce the
pressure loss and thus the energy loss at a given amount of air. This re-
duces the necessary negative pressure in the house.
Use one unit per inlet.
401364 DA 1540/1800 insert module
DA 1540/1800 insert module is used to reduce the air capacity in a single
pen, often at the end of an inlet row. The insert module can be used with
the inlet funnel.
The insert module reduces the air capacity by 50 %.
Use one unit per inlet.
437482 DA 1500/1800 pipe holder
For DA 1540/1800 ceiling inlet a special pipe hanger has been developed,
which can be used for securing high pressure cooling pipes from SKOV A/
S, if high pressure cooling is installed. The pipe holder can only be used
when the ceiling pitch is 0°.
Use one unit per inlet.
If the distance between the inlets exceeds approx. 1.5 m supplement the in-
let by item no. 437480 DA 1540/1800 pipe holder with adapter.
If the length of the cooling piping exceeds 40 m, the pressure impact from
the start/stop of pump may cause breakage of the rather long pipe holder.
DA 1800 CD Ceiling Inlet
Mounting Guide 7
437480 DA 1540/1800 pipe holder with adapter - 0.5 m
Used where extra support of the cooling pipe is required. Height approx. 49
cm which means that it is suited for the 437482 pipe holder for DA
1540/1800. The pipe holder can only be used when the ceiling pitch is 0°.
Mount it directly on the ceiling with the two screws supplied.
In Denmark one unit per 1.2 m free-hanging cooling pipe is used - corre-
sponding to normal lath distance.
If the length of the cooling piping exceeds 40 m, the pressure impact from
the start/stop of pump may cause breakage of the rather long pipe holder.
401335 DA 1500/1800 holder for pullrod
Is applied if the distance between the inlets exceeds 2m.
Mounted vertically with two screws in the ceiling.
DA 1800 CD Ceiling Inlet
8 Mounting Guide
3 Mounting guide
Before mounting check that
the building matches the drawings as regards placement, ceiling pitch and ceiling type.
the part delivery matches the order/item lists.
3.1 Recommended tools
A list of the recommended tools for mounting purposes can be seen below.
Item Description
Cordless drill
Screwdriver bits
Drill kit
Utility knife
Spirit level
Marker pens
Tape measure
Ladder
Try square
DA 1800 CD Ceiling Inlet
Mounting Guide 9
3.2 Placement in ceiling
The inlet should not to be placed over trough as dripping may occur.
Make sure that there is free space for pull rod and inlet flap.
The insulation material must fit tightly around the inlet.
Take care of various obstacles such as pipes, light fittings, electric cables, etc.
Here, the inlet is shown from above.
Cutout dimension 500 mm x 395 mm.
Make sure that there is room for the outer dimensions of
the inlet, see technical data.
Take care of various obstacles such as pipes, light fit-
tings, electric cables, etc.
Adapt a template of cardboard or a wooden board with
the dimensions 500 × 395mm.
Mark the selected spot and cut out.
Take care of electric cables in the ceiling, if any.
3.3 Preassembly
Mount arm for flap and arm for pull rod and lock the inlet
flap by means of the string.
Place the four screws in the corners.
DA 1800 CD Ceiling Inlet
10 Mounting Guide
3.4 Mounting lengthwise of boarding
With this kind of mounting, the tolerances are small, so
be careful not to damage the insulation on the sides of
the inlet.
Lay out insulation material.
Place the inlet funnel as shown.
3.5 Mounting across boarding
Place an extra board as shown here.
Lift the inlet into place and fasten the inlet with four
screws.
Lay out insulation material.
Place the inlet funnel as shown.
It is important that the inlet flap closes tightly.
Adjust misalignments by tightening/slackening the four mounting screws.
3.6 Mounting the string
Mount clips with string on the pull rod.
Mount string with lock for piano wire on the wire.
DA 1800 CD Ceiling Inlet
Mounting Guide 11
3.7 Mounting on sloping surfaces
In some cases, sloping surfaces/ceilings make con-
densed water which runs into the flap.
Drill two Ø 2.5 mm holes in the flap to ensure that the
flap is drained by this mounting method.
DA 1800 CD Ceiling Inlet
12 Mounting Guide
4 Maintenance instructions
TheDA 1800 does not require special maintenance. Periodically, string and spring are checked for wear.
The product may be cleaned by a high-pressure cleaner without using:
• solvents
corrosive/caustic agents
4.1 Recycling/Disposal
Products suitable for recycling are marked with a pictogram.
It must be possible for customers to deliver the products to local collection sites/recycling stations in accordance
with local instructions. The recycling station will then arrange for further transport to a certified plant for reuse,
recovery and recycling.
DA 1800 CD Ceiling Inlet
Mounting Guide 13
5 Technical data
Mechanical
Material 100% recyclable thermoplastic, high-impact material, dimensionally
stable and UV stabilized
Color Black
Fan output
30 cm opening With inlet funnel Excl. inlet fun-
nel
Air output at -5 Pa m3/h 800 1250 1400 900
Air output at -10 Pa m3/h 1150 1800 1950 1250
Air output at -20 Pa m3/h 1600 2550 2800 1800
Air output at -30 Pa m3/h 1950 3100 3400 2200
Air output at -40 Pa m3/h 2550 3550 3950 2550
Environment
Temperature, operation °C (°F) -40 to +40 (-40 to +104)
Storage temperature °C (°F) -40 to +65 (-40 to +149) – and protected against direct sunlight.
Ambient humidity, opera-
tion
% RH 0-95 % RH
Shipment
Weight g 3700
5.1 Dimensioned sketch
DA 1800 CD Ceiling Inlet
14 Mounting Guide
603882 • 2020-08-28 • en-US • Made in Denmark
SKOV A/S • Hedelund 4 • Glyngøre • DK-7870 Roslev
Tel. +45 72 17 55 55 • www.skov.com • E-mail: [email protected]
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16

Skov DA 1800 Ceiling Inlet Mounting Guide

Type
Mounting Guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI