Roche Cedex HiRes Reference guide

Type
Reference guide

Roche Cedex HiRes is an automated cell counter and analyzer that provides accurate and reliable cell counting and analysis for various applications in life science research and biopharmaceutical manufacturing. With its advanced technology, the Cedex HiRes offers:

  • High-Resolution Imaging: Utilizes high-resolution digital imaging to capture detailed images of cells, enabling accurate cell counting and classification.

  • Automated Cell Counting and Analysis: Automates the process of cell counting and analysis, providing consistent and reproducible results. This eliminates manual counting errors and streamlines the workflow.

Roche Cedex HiRes is an automated cell counter and analyzer that provides accurate and reliable cell counting and analysis for various applications in life science research and biopharmaceutical manufacturing. With its advanced technology, the Cedex HiRes offers:

  • High-Resolution Imaging: Utilizes high-resolution digital imaging to capture detailed images of cells, enabling accurate cell counting and classification.

  • Automated Cell Counting and Analysis: Automates the process of cell counting and analysis, providing consistent and reproducible results. This eliminates manual counting errors and streamlines the workflow.

1 / 2
For use in quality control/manufacturing processes only.
Performing a Measurement — (April 2014)
Moving parts of the Multi Sampler may cause hand injuries. The Multi Sampler needle
may cause injuries during operation. Never use the Cedex HiRes Analyzer without the
protective cover in place for the Multi Sampler.
Start the Cedex HiRes Analyzer and software
1
Switch on the Cedex HiRes Analyzer.
2
Switch on the monitor and PC.
3
Log in to Windows Operating System.
4
Start the Cedex Software 2.3 by double clicking on the Cedex Client icon located on the
desktop (the Cedex Server should already be automatically started. It must be first started
before the Cedex Software 2.3 can be started). The Log In dialog box of the Cedex HiRes
Software 2.3 program will open.
5
Enter the username in the User Name field and password in the Password field and press
<Return>. The Cedex Control Center appears after a successful login.
Perform a Hardware Startup and Prime
1
Click on the HWM button in the Cedex Control Center to open the Hardware Management
dialog box.
If the Hardware Management has not been started, the current status field will
have the message “Not started”.
2
Click on HW Startup if the Hardware Management has not been started. The Hardware
Management will start and the current status field will have the message “HW started and
LM not primed”.
3
Ensure that a clean, empty Cedex Sample Cup is correctly positioned on the Multi Sample
Tray in the DefaultCup position (usually sample cup position 1), or on the single sample port,
and click on Prime in the Hardware Management dialog box.
Carry out a single measurement
1
Click on the MEASURE button in the Cedex Control Center to open the Measurement
dialog box.
2
In the Measurement dialog box, enter a clearly defined Reactor ID to describe the sample
(e.g. the name of the cell culture or bioreactor name) in the Reactor ID area. You may either
choose a Reactor ID from the drop down list or enter a new Reactor ID.
3
Enter a clearly defined Sample ID in the Sample ID area. Multiple Sample IDs can be listed
under one Reactor ID. The Sample ID can be freely defined.
4
Choose the appropriate dilution factor from the Dilution drop-down list. For undiluted
samples, enter a dilution factor of 1:1. When a dilution of 1:2 is prepared, then
1 part cell
suspension has been added to 1 part dilution medium. A dilution of 1:3 means that 1 part
cell suspension has been added to 2 parts dilution medium. The dilution factor will be
automatically taken into account in the results.
5
Select the sample volume of 300 µL in the Volume drop-down menu.
6
Enter comments (if desired) in the Comment box.
7
Select the sample port type in the Sample Port drop-down list:
c Auto Sampler or Multi Sampler: for systems with a Multi Sampler.
c Single: for systems with a single sample port.
8
Enter the cup position for the sample in the Cup Position dialog box if there is a Multi
Sampler.
9
Select the cell type that optimally recognizes your cells from the Cell Type drop-down list:
c Min. Size: small cells with a diameter of about 6 µm.
c Std. Size: normal sized cells with a diameter of about 12 µm.
c Max. Size: large cells of more than 16 µm.
If a new cell type has been created, it can also be selected from the same Cell Type
drop-down list.
Do not select the Cell Type option HR-Illumination, if it is available. This Cell Type is
designed for service purposes only and is not intended for analysis of cells.
ccc
Cedex HiRes Software 2.3.2 Quick Guide
2 / 2
07267070001
3
042014
For use in quality control/manufacturing processes only.
CEDEX is a trademark of Roche.
All other product names and trademarks are the property of their respective owners.
Performing a Measurement — (April 2014)
10
Select the desired precision level in the Precision drop-down list:
c Minimum: 3 images are used for the analysis.
c Normal: 6 images are used for the analysis.
c Superior: 8 images are used for the analysis.
c Maximum: 11 images are used for the analysis.
11
Prepare the sample. The Cedex HiRes Analyzer requires a volume of 300 µL +/- 10%.
Any greater variation in sample volume will lead to inaccurate results.
12
Attach the Cedex Sample Cup containing the sample to the sample port, or place it in the
appropriate
sample cup position on the Multi Sample Tray. The sample cup is correctly
attached to the
single sample port when it is in an upright position directly beneath it and
the capillary tube almost reaches the base of the sample cup.
13
Click on the START MEASUREMENT button to start the measurement.
14
When the measurement is finished, the top section of the Result Data area in the
Measurement dialog box will display the overall results from the measurement. The bottom
section displays, in succession, the results from each image taken.
Logging out and/or shutting down
1
Open the Hardware Management dialog box (HWM button on the Cedex Control
Center).
2
Click on LM Shutdown to shut down the Liquid Management system.
3
Click on the LOGOUT button on the Cedex Control Center to log out of the Cedex Control
Center. The Cedex Control Center software program will be ended, and the login dialog
box will
reappear.
4
Alternatively, shut down the software by selecting Exit under the System menu or by
clicking on to close the Cedex Control Center dialog box.
5
The security query, “Do you really want to exit the Cedex Control Center?“, will appear.
Click on Yes to shut down the program.
6
In the case of a Multi Sampler, a sample cup should always be left in the DefaultCup position
on the Multi Sample Tray (see Quick Guide “Working with the Multi Sampler”). In the case of
a single sample port, the sample cup from the last measurement should remain attached to
the sample port during the entire shutdown procedure and should only be removed when a
new sample cup has been attached for the next measurement.
Published by:
Roche Diagnostics GmbH
Sandhofer Strasse 16
68305 Mannheim
Germany
Cedex HiRes Software 2.3.2 Quick Guide
  • Page 1 1
  • Page 2 2

Roche Cedex HiRes Reference guide

Type
Reference guide

Roche Cedex HiRes is an automated cell counter and analyzer that provides accurate and reliable cell counting and analysis for various applications in life science research and biopharmaceutical manufacturing. With its advanced technology, the Cedex HiRes offers:

  • High-Resolution Imaging: Utilizes high-resolution digital imaging to capture detailed images of cells, enabling accurate cell counting and classification.

  • Automated Cell Counting and Analysis: Automates the process of cell counting and analysis, providing consistent and reproducible results. This eliminates manual counting errors and streamlines the workflow.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI