  • Hello! I am an AI chatbot trained to assist you with the WaterLogic WL100 Operating, Installation And Service Manual. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Waterlogic Commercial Products, LLC
11710 Stonegate Circle
Omaha, NE 68164
(800) 288-1891 www.waterlogic.us
Tech Portal Website: www.techportal.waterlogic.com
WL100
OPERATING, INSTALLATION, AND SERVICE MANUAL
WL100Operating,Installation,andServiceManual Page2Revision:5202016
WL100OPERATING,INSTALLATION,ANDSERVICEMANUAL
CongratulationsonyourchoiceoftheWaterlogicWL100WaterTreatmentSystem.TheWL100
WaterTreatmentSystemdispensescold,andhot.EveryWL100WaterTreatmentSystemincludes:
BioCoteAntiMicrobialProtection
Filterconfigurationcanbeoptimizedforallwaterconditions
TheWaterlogicWL100WaterTreatmentSystemprovidesexceptional
qualityandgreattasting
waterwitheveryuse.
TABLEOFCONTENTS
FeaturesandBenefits.................................................................3
Certifications...............................................................................4
IntroductionandSafetyAlertSymbols.......................................5
SafetyPrecautions......................................................................6
ModelandPartDesignations......................................................7
Specifications..............................................................................7
OperatingInstructions................................................................8
HotTankPrinciplesofOperation................................................9
FlowDiagram............................................................................10
DisablingEnergyStarSleepMode............................................11
ChangingHotWaterModetoAmbient....................................12
AdjustColdSetPoint................................................................13
PreInstallationProcedures......................................................14
DrainingProcedures..................................................................17
InstallationProcedures.............................................................21
ServiceRequirements...............................................................23
ReplacementComponents.......................................................24
HotTankDescalingInstructions...............................................25
ResettingtheHotTankOverloadorHighLimitSafety.............27
HeaterCircuitHotTankWiring..............................................29
CounterTopDrawingsandPartLists……………………..................30
TowerDrawingsandPartsLists................................................36
ElectricalDiagrams....................................................................42
Troubleshooting........................................................................43
Warranty..................................................................................65
WL100Operating,Installation,andServiceManual Page3Revision:5202016
WL100FEATURESANDBENEFITS
Ambient,ColdandHotWater
Ambient,ColdandHotWaterSelectionstomeetawiderangeofcustomerdemands.Cold
temperatureisadjustable.
HighVolumeStorageandWaterCapacity
WL100WaterTreatmentSystemshave2Liter(0.5Gallon)Coldtanksand1.6Liter(0.4Gallon)Hot
Tanks.
BioCote®AntiMicrobialProtection
Plasticsurfacessurroundingdispensingareasanddriptrayareinfusedwithan
exclusivesilveradditivecalledBioCote®.Silverisanaturalantimicrobialthat
inhibitsthegrowthofmicroorganismsprovidingadditionalsurfaceprotection.
RecessedFaucet
BioCote®Faucet(Spigot)isrecessedintounittoprotectfromcrosscontamination.
LargeDispenseArea
8.5inchdispenseheighttoaccommodatemostcupandbottlesizes.
ChildSafeguard
TheWL100WaterTreatmentSystemrequiresusertoselectandholdbothRedButtonstoprevent
accidentaldispensingofhotwater.

EnergySavingSleepMode
EnergysavingSleepModecanbeprogrammedtoturnoffheaterafter3ofinactivityandcanbeshut
off.
AuxiliaryPort
AuxiliaryPortattherearoftheCounterTopModelstofeedCoffeeMachinesorotherappliances.
StainlessSteelTanks
Peaceofminddrinkingfromhighquality,sealedstainlesssteelreservoirs.
AdvancedFiltration
TheWL100WaterTreatmentSystemTowerequippedwitheasyaccess
filtermountingtraythatallowsdealerstooptimizefilterconfigurationfor
allwaterconditions.
HighCapacityRemovableDripTray
HighCapacityRemovableDripTraywithBioCote®protection.Driptrayis
twopieceforeasycleaningandcomesconfiguredwithoptionaldrainport.

WL100Operating,Installation,andServiceManual Page4Revision:5202016
WL100CERTIFICATIONS
Waterlogicwatertreatmentsystemshavebeentested,andcertifiedtorigorousNSFandUL
Standards.WebelievethatperformancetestingandcertificationsvalidateWaterlogicasaworld
leaderinwatertreatmentsystems.
WL100WaterTreatmentSystemCertificationsInclude
UL399CertifiedDrinkingWaterCooler
IntertekLabs(ETL)CertifiedtheWL100WaterTreatmentSystemstoANSI/UL399
StandardforDrinkingWaterCoolers.
BPAFree‐WaterlogictestsforBPAanddeclaresthatallofitsproductsareBisphenolA
FREEandcontainnoharmfulBPAplastics.
NSF/ANSI61CertifiedDrinkingWaterSystemComponents
TheWL100WaterTreatmentSystemhasbeentestedandcertifiedbyTheWater
QualityAssociation(WQA)toNSF/ANSI61,Section9.
EnergyStarCertified
TheWL100WaterTreatmentSystemhasbeentestedandcertifiedtotheEnergyStar,a
USEnvironmentalProtectionAgency(EPA)programthathelpsourcustomerssave
moneyandprotectourclimatethroughsuperiorenergyefficiency.
WaterlogicmanufacturingiscertifiedtoISO9001QualityManagement
Systems(certifiedbyMoodyInternational).ISO9001isthe
internationallyacceptedstandardforwellmanagedorganizationsthat
haveadoptedthekeyqualitymanagementprinciplestoitsoperationsto
bringconsistentqualityproductsandacultureofcontinuous
improvement.
SafeDrinkingWaterAct
WaterlogicwatertreatmentsystemsconformtotheSafeDrinkingWaterAct(SWDA)“leadfree”
amendmenteffectiveJanuary4,2014.
ADACompliance
Waterlogicdesignswatersystemstobeergonomicandmeetthehigheststandardsavailablewhile
consideringusebydisabledandphysicallyimpairedusers.SeeourADAPositionStatementfor
futuredetails.
WL100Operating,Installation,andServiceManual Page5Revision:5202016
INTRODUCTION
CarefullyreadandfollowallinstructionstoensureproperandefficientoperationofyourWL100
WaterTreatmentSystem.ContactWaterlogicoranAuthorizedWaterlogicDealerifyouhaveany
questions.
WaterlogicandAuthorizedWaterlogicDealersemploytrainedservicepersonnelwhoare
experiencedintheinstallation,functionandrepairofWaterlogicequipment.Thispublicationis
writtenforusebythesequalifiedindividuals.Waterlogicencouragesuserstolearnaboutproducts,
however,webelievethatproductknowledgeandserviceisbestobtainedbyconsultingWaterlogic
oranAuthorizedWaterlogicDealer.
Waterlogicwatertreatmentsystemsshouldbecombinedwithselectedwatertreatment
componentstocreateasystemspecificallytailoredforeachapplicationbytrainedandqualified
personnel.
ProductsmanufacturedandmarketedbyWaterlogicanditsaffiliatesareprotectedbypatents
issuedorpendingintheUnitedStatesandothercountries.
Waterlogicreservestherighttochangethespecificationsreferredtointhisliteratureatanytime,
withoutpriornotice.ChangesormodificationsnotexpresslyapprovedbyWaterlogiccouldvoidthe
warrantyanduser’sauthoritytooperatetheequipment.
SAFETYALERTSYMBOLS
Readandfollowallsafetyinformationcarefully.Thesignalwordsusedinthismanualareselectedas
shownbelowandbasedonanassessmentofthedegreeofpotentialinjuryordamage(severeor
minor)andtheoccurrenceofinjury(definitelyoccursorhasthepotentialtooccur)whenthe
warning
isignored:
DANGER!
Indicatesasituationwhich,whennotavoided,resultsindeathorsevereinjury.
WARNING!
Indicatesasituationwhich,whennotavoided,hasthepotentialtoresultindeathorsevere
injury;and/orseverepropertydamage.

CAUTION!
Indicatesasituationwhich,whennotavoided,resultsorhasthepotentialtoresultinminor
injury;and/orminorpropertydamage.

WL100Operating,Installation,andServiceManual Page6Revision:5202016
SAFETYPRECAUTIONS
Basicsafetyprecautionsshouldbefollowed,includingthefollowing:
DANGER!Ifincorrectlyinstalled,operatedormaintained,thisproductcancausedeathor
severeinjury.Thosewhoinstall,operate,ormaintainthisproductshouldbetrainedinitsproper
use,warnedofitsdangers,andshouldreadtheentiremanualbeforeattemptingtoinstall,
operate,ormaintainthisproduct.
WARNING!Unitistobeusedforitsintendedpurposeasdescribedinthismanual,and
untrainedindividualswhousethismanualassumetheriskofanyresultingpropertydamageor
personalinjury.
WARNING!HOTWATER.UnitproducesHotWaterupto87
o
C(189
o
F).Waterabove52°C
(125°F)cancausesevereburnsorscalding.Keepunauthorizedpeopleandchildrenawayfromthe
unittoavoidaccidentaldispensingofhotwater.Childrenshouldnotusewithoutsupervision.
DANGER!ELECTRICALSHOCKHAZARD.Alwaysunplugfrompowersupplypriortoservicing
equipmenttopreventelectricalshock.
WARNING!Thissystemtobeusedforwateronlyandisnotintendedforusewherewateris
microbiologicallyunsafeorwithwaterofunknownqualitywithoutadequatedisinfectionbefore
orafterthesystem.Thesystemisdesignedforthesupplementalbactericidaltreatmentofeither
treatedanddisinfectedpublicdrinkingwater,orotherdrinkingwater,whichhasbeentestedand
deemedacceptableforhumanconsumptionbythestateorlocalhealthagencyhavingjurisdiction.
Thesystemisdesignedtoreducenormallyoccurringnonpathogenicornuisancemicroorganisms
only.Systemisnotintendedfortreatmentofcontaminatedwater.
WARNING!DispenserCouldTiporFallcausingSeriousInjury.Alwaysinstallunitonafirm,flat,
andlevelsurfaceandsecuretheWL100WaterTreatmentSystemtothebasecabinetwiththe
screwprovidedtolockthecomponentstogether.Neverplaceheavyitemsontopofunitandnever
climb,stand,orhangonunitorstoragecabinettopreventinjuryanddamage.

CAUTION!INDOORUSEONLY.Donotinstalloutdoorsorwhereunitisindirectsunlight.Donot
installwhereambienttemperaturegoesbelow10°C(50°F)orabove36°(97°F).Avoidhigh
humidityandmoisture.Productlifeandperformancewillbeimpactedandwarrantycouldbe
voided.
WL100Operating,Installation,andServiceManual Page7Revision:5202016
MODEL/PARTDESIGNATIONS
BRANDNAME DESCRIPTION
MODEL‐
PARTNUMBER
WL100CounterTop
WaterlogicWL100CounterTopColdandHot 12CHCM
F100MHCTTCSWLU
WL100Tower
WaterlogicWL100TowerColdandHot 12CHC
F100FSHCTTCSWLU
SPECIFICATIONS
ITEM WL100CounterTop WL100Tower
WaterConnection ¼”QuickConnect
ColdWaterTemperature
ColdWaterTemperature
FactorySetPoint41°‐ 5°C
Adjustableto34° - 54° F.(1.1°‐12.2°C)
HotWaterTemperature 85°C(185°F)
HotWaterManualReset
Overload
105°C(221°F)
RecommendedService
Pressure
4060psi(275414kPa)UsePressureRegulator
MaximumServicePressure 100psi(689kPa)UsePressureRegulator
RatedServiceFlow 1.89Litersperminutes(0.5gallonsperminute)
EnvironmentalTemperature35°‐100°F(2°‐37°C)
Heater 500W
RefrigerantGas R134a,40g,1.41ounces R134a,45g,1.59ounces
R134aPressures High(230psi),Low(90psi)
SHIPPINGSPECIFICATIONS
ITEM WL100CounterTop WL100Tower
Width/Depth/Height
13.5”x16”x17.75”
#
(34cmx41cmx
45cm)
13.5”x16” x40.5”(34cmx41cmx
103cm)
Weight(dry) 40pounds(18kg) 50pounds(23kg)
ELECTRICALSPECIFICATIONS
ELECTRICALSUPPLY 120V/60Hz,1PH 15AmpService
COMPONENT POWER(approximate) AMPDRAW(approximate)
Heater 504 4.2Amps
Compressor 168 1.4Amps
WL100TOTAL 672 5.6Amps
#WL100CounterTopis17.75in.tallandmaynotfitbetweencountertopsandcabinets‐Checkinstallationtoensureadequateclearance.
WL100Operating,Installation,andServiceManual Page8Revision:5202016
OPERATINGINSTRUCTIONS
TheabovepictureshowsfrontLCDdisplayandcontrolpanelfortheWaterlogicWL100Water
TreatmentSystem.
ForColdWater PresstheBlue‐ColdWaterSelectButton
ForHotWater
PressthetwoRed‐HotWaterSelectButtonsatthe
sametime.
ThisisaSafetyFeaturetopreventaccidentaldispensing
ofhotwater.

ColdWaterDispense
PressBothforHot
WaterDispense
WL100Operating,Installation,andServiceManual Page9Revision:5202016
HOTTANKPRINCIPLESOFOPERATION
AllWaterlogicHotTankshaveabuiltinVentor
ExpansionChamberinthetopofthetankexceptfor
WL270(GF)units.
TheVentChamberallowsforexpansionofthewater
whenitisheated.
Thechambersareseparatedbyaweldedintank
baffle.
Wateralwaysflowsintothebottomofthetankand
outthetoptothefaucet.
Thehottankoutlettubehasarestrictorinitsbase.
Thisensuresthereservoirisalwaysfullbyallowing
morewaterinthanout.
Thereisasmallholeinthesideofthetankoutlettube
thatallowsairandwatertopassintothevent
chamberasitisheated.
Waterintheventchamberissuctionedbackthrough
theoutlettubeventholewhenwaterisdispensed.
Expansionofwaterasitisheatedinthereservoirwill
pushthewateroutthefaucetwhentheoutlettube
ventholebecomespluggedwithdebrisorscale.
ThesmallOutletVentHoleissusceptibletoscalebuild
upandisakeyindicatorthatdescalingisrequired.
Itiscriticaltodescalethehottankthroughthevent
lineandoutletlineonaregularbasistopreventthis
problem.
Descalingthroughtheinletand/oroutletlinesonly
willnotcleantheventchamberandoutletventhole
properly.

WL100Operating,Installation,andServiceManual Page10Revision:5202016
WL100WATERFLOWDIAGRAM
WL100Operating,Installation,andServiceManual Page11Revision:5202016
PROGRAMMINGINSTRUCTIONS
DISABLINGENERGYSAVINGSLEEPMODE
AllWL100WaterTreatmentSystemscomefromthefactorywithEnergySavingSleepMode
engagedtomeettheEnergyStarCertificationrequirements.EnergySavingSleepModedisables
theheatercircuitiftheunithasnotbeenusedforacontinuous3hourorlongerperiod.
Selectinganybutton"wakesup"theWL100WaterTreatmentSystemandturnstheheater
circuitbackon.TheHotTankwilltypicallytakelessthan10minutestoheatthewaterfrom
ambienttothe85°C(185°F)setpoint.
UnplugPowerCordandremoveTopCovertoaccessEnergySaverPCB.
WL100WaterTreatmentSystemcomeswiththe
EnergySavingSleepMode“ON”
PCBJumperJP7inthe"ON"position(Pin1and2)
DeactivatetheEnergySavingSleepModebymoving
PCBJumperJP7tothe"OFF"position(Pins2and3).
EnergySaverPCBP/NEN6131WLCPPN200075
PinNumbers
1 2 3
2
3
1
2
WL100Operating,Installation,andServiceManual Page12Revision:5202016
PROGRAMMINGINSTRUCTIONS
CHANGINGHOTWATERMODETOAMBIENTWATER
AllWL100WaterTreatmentSystemshavefactorysettingtoHotandCold,whichcanbechanged
toAmbientandColdWatersettings.
UnplugPowerCordandremoveTopCovertoaccessEnergySaverPCB.
Onthe
EnergySaverPCB,MovetheJumperonJP9fromPins1and2toPins2and3.
TheWL100WaterTreatmentSystemcomeswith
HotandColdWaterfactorysettings.
PCBJumperJP9inpositions‐Pin1and2
ChangetoAmbientandColdbymovingPCB
JumperJP9topositionsPin2and3
1 2
2 3
EnergySaverPCBP/NEN6131WLCPPN200075
1 2 3
PinN
u
m
be
r
s
WL100Operating,Installation,andServiceManual Page13Revision:5202016
ADJUSTINGCOLDSETPOINT
ThecoldsetpointcanbeadjustedbyaccessingtheColdThermostat
adjustmentscrewUndertheDecalattherearoftheunit.
ThiswillNOTVoidtheWarrantyasthecurrentDecalstatesonthebackof
theunit.Thefactorysetpointis5°C(41°F)thatisindicatedwiththedot
onsheetmetalaroundtheadjustmentscrewandbehindthedecal.
Turningtheadjustmentscrewclockwiselowersthesetpointtemperature
andtherangeisapproximately‐6.7°C(20°F)thruthefullrangeof
adjustment(~7:00tothe~5:00positions).
Youshouldbeabletoturnthescrewfromthefactorysetpoint5°C(41°F)
(~12:00position)about45degreesclockwise(2:30onaclock)toreduce
thesetpointtemperatureby‐14.4°C(6°F)andachievethe1.7–2.2°C(35
36°F)settingyouarelookingfor.

Trialthisbyadjustingandthenmeasurethewatertemperature1015
minutesafterthecompressorshutsoff(coldestpoint)toverifytheset
pointtemperature.

Eachunitwillvaryslightly.Trynottogomuchpastthe“3:00position”to
avoidfreezingthecoldtankasshownabove.
FUTUREPRODUCTIONWILLINCLUDECOLDTHERMOSTATCOVERLABEL
PartNumber:LP0326L0000/WLCPPNLP0326
WL100Operating,Installation,andServiceManual Page14Revision:5202016
PREINSTALLATIONPROCEDURES
DANGER!ELECTRICALSHOCKHAZARD.
Onlyqualifiedpersonnelwhohavereadandunderstandthisentiremanualshouldattemptto
install,orservicethisunit,failuretodosocouldresultindeathorseriousinjury.DONOTplug
intoanelectricalsupplyuntilspecificallyinstructed.
WARNING!ALWAYSSANITIZEBEFOREUSE.
Sanitizebeforeusetoeliminateanypotentialmicrobiologicalcontaminates.
MaterialsNeeded:
PersonalProtectiveEquipment.RubberorNitrileSafetyGlovesandProtectiveEyewear
PhillipsScrewdriver
TemperatureGauge
WaterPitcherorContainertocollectwaterfromthefaucet
19Liter(5gallon)containerordrainbasin
Sanitizer‐HouseholdBleach(5.25%SodiumHypochlorite)orCitric AcidBasedCleaner
¼”PlasticTubing,atleast4feetinlength,andassorted¼”quickconnectfittings
TDSMeterandTestStripsformeasuringchlorineOptional
SanitizingCartridgeanemptyWaterlogicFilterwithcartridgeremoved
1. UnpacktheWaterlogicWL100WaterTreatmentSystemandcheckexteriorfordamage.

Sanitizing
SanitizeusingaHouseholdBleach(5.25%SodiumHypochloritesolution)orotherapproved
cleanerthroughoutthecoldwatercircuit.Followallinstructionsonthesanitizerandflushwith
freshwaterthroughthefaucetuntilodorandtasteisacceptable.
WARNING!USEPROPERPERSONALPROTECTIVEEQUIPMENT
Alwaysensureproperventilationanduseproperpersonalprotectiveequipmentsuchasgloves
andeyeprotectionwhenusingchemicals.RefertoMaterialSafetyDataSheetforspecific
requirementsofeachchemicalproduct.Takeallnecessaryprecautionstopreventsanitizerfrom
contactingeyes,clothing,andanyothersurfacesincoulddamage(carpets).

2. Put5Millimeter(1Teaspoon)ofsanitizerperdirectionsoruseBleachSolution(5Millimeter=1
Teaspoon=1/6ounces=½capfull)ofhouseholdbleach(SodiumHypochlorite5‐10%
Concentration)intheSanitizingCartridge.Alwaysensuresanitizeriscompatiblewithstainless
steelandacetylplastic.
3. Connectsanitizingcartridgetoinletwatersupplyandconnecttoinletbulkheadfittingonbackof
unit.Turnonwatersupply.
4. ConnectpowertotheWL100WaterTreatmentSystem.DONOTTURNONRED
HEATERCOMPRESSORSWITCHATTHISTIME. RedCompressor/HeaterSwitch
mustbeintheO=OFFposition.
WL100Operating,Installation,andServiceManual Page15Revision:5202016
FilltheColdCircuitwithSanitizer
5. DepresstheMainDispensingButtonontheFrontControlPaneluntilcoldwater/sanitizing
solutioncomesoutthefaucet.NOTE:Containeranddrainbasinwillberequiredtocatchthe
waterfromthefaucet.
WARNING!UsePersonalProtectiveEquipment.GlovesandEyeProtectionRequired.Thefirst
8or11Liters(2or3gallons)ofwaterwillcontainconcentratedsanitizer.Useextremecare!
6. TurnoffwatersupplyandremoveSanitizingCartridgefrominletwatersupply.Reconnectwater
supplytoinletbulkheadfitting.
FlushFilters
CAUTION!FILTERFLUSHREQUIRED.
WL100WaterTreatmentSystemsarenotsuppliedwithfilters.Filtersshouldbeconfiguredto
optimizeyoursystem.Filtersneedtobeconfiguredandspecifiedtodothejobgiventhelocal
waterconditions,usage,maintenanceschedule,andplacementrestrictions.

Inorderforourfilterstoperformasrepresentedandtoprovidethebestqualitywaterpossible,it
isessentialthatfiltersbereplacedperiodically.Thefrequencyoffilterchangesdependsuponyour
waterqualityandyourwaterusage.Forexample,ifthereisalotofsedimentand/orparticlesin
yourwater,thenyouwillhavetochangeyourfiltersmorefrequentlythanalocationwithlittleto
nosediment.Besuretoreplaceyourfilterswheneveryounoticeadeclineintheperformance,
whetheritisadropinflowrateand/orpressureoranunusualtasteinthewater.
7. Flushthoroughlyperfiltermanufacturers’recommendationwithfreshwatertodrain.
8. Onceflushed,installthefilters.Followingtheflowdirectiononthefilter.
NOTE:

Filtersshouldnotbeflushedpriorto24hoursbeforeinstallationtolimitMicrobial
Growth.
9. ConnectWL100WaterTreatmentSystemtopower.
CAUTION!NEVERTURNONHEATERBEFOREFILLINGHOTTANK.
RedCompressor/HeaterSwitchmustbeintheO=OFFpositionwhiletheHot
Tankisempty.Damagecouldoccurwithinoneminuteandtheoverload(high
limit)willrequiremanualresetifHeateristurnedonwithanemptyHotTank.
WL100Operating,Installation,andServiceManual Page16Revision:5202016
FlushingtheSanitizerfromtheMachine
10. Placeapitcher,catchbasin,orothercontainerunderthefaucetoftheWL100WaterTreatment
System.
11. FlushtheColdTank.Runseveralgallonsofwaterthroughthefaucetbydispensingcoldwaterto
diluteandremovethesanitizerfromthecoldcircuit.Chlorineteststripscanbeusedtoevaluate
thewater.
12. Oncethesanitizerodor/taste hasbeenflushedoutofthecoldsideofthemachinethe
sanitizationprocessfortheColdCircuitisnowcomplete.
FilltheHotTank
13. PresstheHotWaterSelectButton,followedbytheMainDispensingButtontofilltheHotTank.
Waterwilldispensefromthefaucetoncethehottankisfull.Flushuntilwaterisclear.
WARNING!HOTCIRCUITISNOTSANITIZED.
WaterintheHotCircuitisnotsanitaryuntilthetemperatureexceeds77°C(171°F)foratleast
5minutes.
CompressorTest
14. SwitchRedCompressor/HeatertoonI=ONposition.AlwaysensureTanksarefull
ofwaterbeforeturningontheHeaterortheOverload(HighLimit)opensand
requiremanualreset.IftheWireCondenseratbackoftheWL100Water
TreatmentSystemiswarm,therefrigerationsystemisworking.

15. Oncethemachinereachesitstargettemperature,thecompressorwillshutoff.Drawaglassof
coldwaterandverifyithaschilledtopropertemperature.
HeaterTest
16. Alwaysensuretanksarefullofwaterbeforeturningontheheaterortheoverload(highlimit)will
openandrequiremanualreset.Itwilltaketheheaterapproximately10minutestoheatthe
waterfromambient75°F(24°C)tothefactorysetpointof185°F(85°C).Dispenseacupofhot
watertoensurethetemperature/odor/tasteisacceptable.
WARNING!HOTWATER.UnitproducesHotWaterupto87
o
C(189
o
F).Waterabove52
o
C
(125
o
F)cancausesevereburnsorscalding.Hotwatershouldbedispensedcarefullyintoinsulated
containertoavoidinjury.

WL100Operating,Installation,andServiceManual Page17Revision:5202016
WL100COUNTERTO PDRAININGINSTRUCTIONS
DrainingNotes
DraintheWL100WaterTreatmentSystemfortransportation.
WARNING!STOREUNITEMPTY.ALWAYSSANITIZEBEFOREREUSE.
Theunitmustbecompletelydrainedandsealedbeforestoringtoavoidstagnationandreduce
microbialgrowth).
PriortodrainingtheHotTank,turnofftheRedHeaterandCompressorSwitch
O=OFF,anddispense2LitersGallon)ofhotwaterfromtheWL100Water
TreatmentSystem.Ashotwaterisdispensedfromthefaucetoftheunit,colder
waterwillbeintroducedintotheHotTank.SincetheRedHeaterandCompressor
Switchisturnedoff,theHeaterwillnotenergizeandheattheincomingtapwater.
Followingthisprecautionpreventsexposingpersonnelandequipment(drains,catchbasin,etc.)
fromscaldinghotwater.
DisableColdandHotTanks
1. TurnofftheRedHeaterandCompressorSwitchtodisabletheheaterandcompressor.
RedCompressor/HeaterSwitchmustbeintheO=OFFposition
2. Dispense2litersGallon)ofwaterthroughtheHotTanktocoolthewater
temperatureintheHotTankandavoidburns.
WARNING!HOTWATER.UnitproducesHotWaterupto87
o
C(189
o
F).Waterabove52
o
C
(125
o
F)cancausesevereburnsorscalding.Hotwatershouldbedispensedcarefullyintoinsulated
containertoavoidinjury.
TurnoffWaterSupplyandBleedWaterPressure
3. IsolateWL100WaterTreatmentSystemfromfeedwaterbyturningoffthesupply.
4. Dispensecoldstillwatertorelieveanypressurebuiltupinthesystem.
DraintheColdWaterTankandCircuit
5. RemoveTopCover.
WL100Operating,Installation,andServiceManual Page18Revision:5202016
6. RemoveFrontPanel.Remove2Phillipscrewssecuring
FrontPanel.
7. UnseatFaucetAssemblyfromFrontPanel.
8. UncliptheWhite,RedandBlackwireconnectorsfrom
PCBtoallowFrontCovertoberemoved.
9. RemoveFrontPanel
10. Disconnecttubingtoallowwaterto
drainfromtheWL100Water
TreatmentSystem.
Catchwaterinapitcher,catchbasin
orothercontainer.
11. Dryinside oftheWL100Water
TreatmentSystem.
12. ReplaceFrontPanel.
WL100Operating,Installation,andServiceManual Page19Revision:5202016
WL100TOWERDRAININGINSTRUCTIONS
DrainingNotes
DraintheWL100WaterTreatmentSystemfortransportation.
WARNING!STOREUNITEMPTY.ALWAYSSANITIZEBEFOREREUSE.
Theunitmustbecompletelydrainedandsealedbeforestoringtoavoidstagnationandreduce
microbialgrowth).
Priortodrainingthehottank,turnofftheRedHeaterandCompressorSwitch(O=
OFF)anddispense2litersGallon)ofhotwaterfromtheWL100Water
TreatmentSystem.Ashotwaterisdispensedfromthefaucetoftheunit,colder
waterwillbeintroducedintotheHotTank.SincetheRedHeaterandCompressor
switchisturnedoff,theHeaterwillnotenergizeandheattheincomingtapwater.
Followingthisprecautionpreventsexposingpersonnelandequipment(drains,catchbasin,etc.)
toscaldinghotwater.
RedCompressor/HeaterSwitchmustbeintheO=OFFposition.
DisableColdandHotTanks
1. EnsuretheRedHeaterandCompressorSwitchisoff(O=OFF)todisabletheheater
andcompressor.
2. Dispense2litersGallon)ofwaterthroughthehottanktocoolthewater
temperatureinthehottankandavoidburns.
3. WARNING!HOTWATER.UnitproducesHotWaterupto87
o
C(189
o
F).Waterabove52°C
(125°F)cancausesevereburnsorscalding.Hotwatershouldbedispensedcarefullyintoinsulated
containertoavoidinjury.
4. Dispensecoldstillwatertorelieveanypressurebuiltupinthesystem.
DraintheColdWaterTankandCircuit
5. RemovetheLowerFrontPanelto
accesstankfeedlines.
WL100Operating,Installation,andServiceManual Page20Revision:5202016
6. RemovetheHotandColdwatersupplylinesfromtheinletlinesolenoids.
7. DisconnecttanklineoutletlinesfromHotandColdsolenoidstodrainintobasinorbucket.
8. TurnoutletfittingsoutwardtoavoidwaterspillingontotheCompressor.
9. ReconnectTubing
intoOutletElbowsoncedrained.
10. Dryinside ofBottomTrayasnecessary.
11. ReplaceLowerFrontPanel

/