CUBEManual Page19–Revision10‐8‐2018
HOTTANKDESCALING
TheHotTankrequiresremovalofmineraldeposits(descaling)onaregularbasis,dependingupon
filtrationandlocalwaterconditions.Descalingisanimportantprocessthatremovescalcium
deposits,orscale,thatcanbuildupinsideatankovertime.Calciumandscaleisnon‐toxicbutleft
unattended,itwillhinderyourunit’sperformance.
HotTankTroubleshooting:Hotwaterintermittentlyforcedoutthroughthefaucetisanindicator
thatdescalingisneeded.ThisoccurswhenscalehasdepositedontheexpansionslotinsidetheHot
Tankventchamberandblocksthenormalpathforwatertoexpand.
Descalingshouldtakeplaceevery6to12monthstopreservethelong‐termhealthofyourunit.Use
non‐toxiccleanersuchasScaleKleen,DEZCAL,20%CitricAcidSolution,orUndilutedVinegar
Solutiontoremovemineraldepositsasdirectedbythemanufacturer.
WARNING!PERSONALPROTECTIVEEQUIPMENTREQUIRED.Alwaysensureproperventilation
anduserubberornitrileglovesandeyeprotectionwhenusingchemicals.RefertoMaterial
SafetyDataSheetforspecificrequirementsofeachproduct.
CAUTION!STAINLESSSTEELTANKDESCALING.
TheHotTankismadefromstainlesssteel.Ensuredescalingsolutioniscompatiblewithstainless
andalwaysflushtheunitcompletely.Disposeinanenvironmentallysafemanner.
SeeHotTankDescalingVideoandtrainingprocedurelocatedonthePartnerAreaoftheWaterlogic
Websiteformoredetailedinstructions.www.waterlogic.us
MaterialsNeeded:
PersonalProtectiveEquipment.RubberorNitrileSafetyGlovesandProtectiveEyewear
PhillipsScrewdriver
TemperatureGauge
WaterPitcherorContainertocollectwaterfromthefaucet
5‐galloncontainerordrainbasin
CitricAcidBasedCleaner
¼”PlasticTubing,atleast4feetinlength,andassorted¼”quickconnectfittings
SanitizingCartridge
FoodColoring
1. Turnofftheincomingwatersupplyattheisolationpoint
2. Selectthecold‐watericonandthenselecttheDispenseButton,when
thewaterstopsflowingreleasethebutton.