WaterLogic WL270 is multi-stage water filtration system capable of both heating and cooling of water to a temperature of your choice. The water filtration system includes an advanced ultraviolet (UV) lamp that disinfects the water by eliminating up to 99.99% of bacteria, viruses, and cysts. The filters remove chlorine, bad taste, odours and other contaminants, providing you with clean and healthy water. The system is designed to be easy to use and maintain, with an intuitive control panel and clear instructions.

WaterLogic WL270 is multi-stage water filtration system capable of both heating and cooling of water to a temperature of your choice. The water filtration system includes an advanced ultraviolet (UV) lamp that disinfects the water by eliminating up to 99.99% of bacteria, viruses, and cysts. The filters remove chlorine, bad taste, odours and other contaminants, providing you with clean and healthy water. The system is designed to be easy to use and maintain, with an intuitive control panel and clear instructions.

WL270Manual Page12Revision222017
SERVICEREQUIREMENTS
WARNING!Readandunderstandthecontentsofthismanualbeforeattemptingtoservice
WL270WaterTreatmentSystem.Failuretofollowtheinstructionsinthismanualcould
resultindeath,seriouspersonalinjury,orseverepropertydamage.Onlytrainedand
qualifiedtechniciansshouldattempttoinstall,maintain,orserviceWaterlogicEquipment.
1. Visuallyinspectallelectricalandwaterconnectionsforsignsofwearordamage.
DANGER!HIGHVOLTAGEELECTRICALHAZARD.Unplugbeforeinspectionandservice.
2. WaterlogicrecommendschangingtheUVLampAssemblyandtheUVLampWiringHarnessmust
bereplacedevery12months.

WARNING!ULTRAVIOLETRADIATION.Protectyourskinandeyesagainstultravioletrays.
NeverlookdirectlyatanoperatingUVlight.DisconnectbeforeremovingUVLamp.
CAUTION!UVLAMPSAREHAZARDOUS.LampsareconsideredHazardousWasteandmust
bedisposedofaccordingly.RefertoProductMSDSsheetfordetails.
3. CleantheQuartzSleevethatsurroundstheUVlampwithanonabrasivecloth,descaling
solution,orultrasonicbathifneededwhenchangingUVLamps.
CAUTION!UVSYSTEMISFRAGILE.NeverhandletheUVlamporQuartzSleevewithbare
hands.UVLampandquartzsleevemustbefreeofoilsandcontaminantstoensureproper
operation.Useasoftnonabrasiveclothtoclean.
4. InspecttheQuartzSleeveOringforwearordamageandreplaceasnecessary.
NOTE:WhenreplacingtheUVLamptheUVLamp
wiringharnessmustalsobereplaced.
NOTE:TheGlowStartershownmayappearblackened
whichisnormal.
WL270Manual Page13Revision222017
5. Ensurethereisadequate(minimumof2”)clearancearoundtheunitandcleanthecondenser
grillandcompressorfantoprovideefficientcoolingsystemoperation.
6. SanitizetheColdTankperinstructionsinthepreinstallationprocedures.
7. Cleanandsanitizeexternalsurfacesoftheunit.Usesoapandwaterorchemicalsthatare
compatiblewithABSplasticandwillnotdamageordegradetheproductsurfaces.
8. RemoveandcleantheFaucet.Replaceasneeded.
WARNING!SANITIZERMAYCONTAINHAZARDOUSCHEMICALS.Useofproperpersonal
protectiveequipmentsuchasrubberglovesandeyeprotectionisrequired.

WL270Manual Page14Revision222017
REPLACEMENTCOMPONENTS
Component WLCPPartNo. FrequencyofReplacement
QuartzSleevefor8WattLamp 101400
Clean12months,orasrequired
PNCT2002
8WUVLampAssembly 102350
Every12months
PNCT2083
HotTankAssembly1.6Liter
110V/500W
HT3028
Every5Years
WLCPPartNo.191071
CarbonAirFilter PU4108
Every12months
WLCPPN191052
ReplacementpartscanbeobtainedfromWaterlogicoranAuthorizedWaterlogicDealer.
SeePartsLayouts,Drawings,andListsforadditionalrepairparts.
HotTankService
HotTanks(withcontrols)mustbereplacedatleastevery35yearsdependingonusage.Descaling
HotTankmayberequiredonaregularbasisdependinguponfiltrationandlocalwaterconditions.
SeeServiceSection.
NOTE:
Attheendofthisproduct’slife,ensurethatitisdisposedofinanenvironmentallyfriendlymanner
whichisfullycompliantwithallFederal/State/LocalRequirementsandGuidelines.

WL270Manual Page15Revision222017
HOTTANKDESCALINGINSTRUCTIONS
TheHotTankrequiresremovalofmineraldeposits(descaling)onaregularbasis.Typically
descalingshouldtakeplaceevery6to12monthstopreservethelongtermhealthofyourunit.
UsenontoxiccleanersuchasScaleKleen,DEZCAL,20%CitricAcidSolution,orUndilutedVinegar
Solutiontoremovemineraldepositsasdirectedbythemanufacturerdependinguponfiltration
andlocalwaterconditions.
Descalingisanimportantprocessthatremovescalciumdeposits,orscale,thatcanbuildup
insideatankovertime.Calciumandscaleisnontoxicbutleftunattendedwillhinderyourunit’s
performance.
WARNING!PERSONALPROTECTIVEEQUIPMENTREQUIRED.Alwaysensureproper
ventilationanduserubberornitrileglovesandeyeprotectionwhenusingchemicals.Referto
MaterialSafetyDataSheetforspecificrequirementsofeachproduct.
CAUTION!STAINLESSSTEELTANKDESCALING.
TheHotTankismadefromstainlesssteel.Ensuredescalingsolutioniscompatiblewith
stainlessandalwaysflushtheunitcompletely.Disposeinanenvironmentallysafemanner.
MaterialsNeeded:
PersonalProtectiveEquipment.RubberorNitrileSafetyGlovesandProtectiveEyewear
PhillipsScrewdriver
TemperatureGauge
WaterPitcherorContainertocollectwaterfromthefaucet
5galloncontainerordrainbasin
CitricAcidBasedCleaner
¼”PlasticTubing,atleast4feetinlength,andassorted¼”quickconnectfittings
SanitizingCartridge
FoodColoring
1. ChecktoensurethattheRedHeaterandCompressorPowerSwitchistheO=OFF
position.
NOTE:SwitcheshaveinternalLEDthatilluminateswhenplacedinI=ONposition.
2. Turnoffthewatersupplyandunplugtheunit.
3. RemovetopCover
4. RemoveReservoirLid
5. RemoveHotTankDraincaponbackofunitandallowallwatertodrainfromunit.
WL270Manual Page16Revision222017
6. Whenunithasfinisheddraining,replaceHotTankdraincap.
7. Removereservoirfromunit.
8. Mixdescalerperinstructions.
9. AdddescalingmixturetotheHotTankthroughtheHotTankfill
portallocatedinthewaterinletport.
10. ReplaceReservoir.
11. Turnonwatersupplyandpluginunit.
12. Allowreservoirtofill.
13. TurnontheRedHeaterandCompressorPowerSwitch.I=ONposition.
14. AllowdescalingmixturetoremaininHotTankfor15minutes(exposuretimemay
beaffectedbylocalwaterconditions).
15. Flushunituntilalldescalerisremoved.
WARNING!HOTWATERHAZARD.UnitProducesVeryHotWaterandSteam.Alwaysuse
insulatedandchemicallycompatiblecontainersandletunitcooldownbeforedrainingtheHot
Tanktoavoidinjury.
CAUTION!MUSTREPLACEHOTTANK35YEARSDEPENDINGONUSAGE.TheHotTankand
itscontrolsmustbereplacedaminimumofevery35yearsdependingonusagetoensure
efficientanddependableoperation.
WARNING!REINSTALLALLPANELSANDCOVERS.Alwaysreinstallallpanels,protective
covers,andfastenersafterservicingequipment.Failuretodosocouldresultinsevere
personalinjuryandwillvoidthecertificationsandwarrantyoftheequipment.

HotTankfillportaltoadd
descalingmixtureto.
WL270Manual Page17Revision222017
RESETTINGTHEHOTTANKOVERLOADORHIGHLIMITSAFETY
1.
TurnoffRedHeaterandCompressorPowerSwitchO=OFFonrearofunit.
2. UnplugthePowerCordfromrearofunit.
3.
Remove4PhillipScrewsfromtheAccessPanelonrear
ofunitandLowerAccessPanel.
4.
LocateprotectivemetalboxonrearofHotTank.Pushdownontopofmetalboxto
accessthermostatandoverload
WL270Manual Page18Revision222017
5.
Presstheresetbutton
6.
Reattachthemetalboxbydepressingthetopflapofthemetalboxsoitsnapsbackinto
itsoriginalpositionontheHotTank.
7.
ReplacetheAccessPaneland4Philipsscrews.
8. PluginthePowerCord.
9.
MakesurethehotandcoldtanksarefilledwithwaterBEFOREturningontheRed
HeaterandCompressorPowerSwitch
CAUTION!NEVERTURNONHEATERBEFOREFILLINGHOTTANK.
RedHeaterandCompressorPowerSwitchmustbeintheO=OFFposition
whiletheHotTankisempty.Damagecouldoccurwithinoneminuteand
theoverload(highlimit)willrequiremanualresetifheateristurnedon
withanemptyHotTank.
10. Verifythecoolerisfullyoperationalbeforeinstallingitatthecustomers’site.

WL270Manual Page19Revision222017
WL270DRAWINGSANDPARTSLISTS

WL270Manual Page20Revision222017
No
WLCPPart
No.
Description PartNo Stocked?
1
195005 BlackTopCover PL1254 Yes
191033 BlueTopCover PL1254A Yes
2 191038 ReservoirCover PL1259 Yes
3 191019 SidePanelSilver ST8212 Yes
4 191034
TopFrontPanelforDripTray
*RequesttobeshippedwithHot
WaterSafetyStickerP/NLP7169
WLCPPN120001
PL1255 Yes
4.1 120001 HotWaterSafetySticker LP7169 Yes
5
195010 BlackTopFrontInsertPanel PL1257 Yes
191036 BlueTopInsertPanel PL1257A Yes
5.1 191014 FrontPanelDisplaySticker LP7180 Yes
6
192025 BlackDripTrayGrill PL1270 Yes
191048 BlueDripTrayGrill PL1270A Yes
7 192020 BlackDripTrayBody PL1289B Yes
WL270Manual Page21Revision222017
191032 BlueDripBody PL1289F Yes
8
195015 BlackFrontBottomPanel PL1149A Yes
191031 BlueFrontBottomPanel PL1149B Yes
9 191035 FrontBottomPanel‐Silver PL1256 Yes
10 191049 LeakTray PL1292 Yes
11 191021 SidePanelBracket ST8229 Yes
12 121602 BottomShelf ST8035 Yes
13 102200
Compressor(R134a1/8HP)
120V/60Hz
CO9001A Yes
13.1 105018 CompressorOverload CO9015 Yes
13.2 103003 CompressorStarterRelay CO9016 Yes
14.1 191025 LeakLevelSensorBracket ST8232 Yes

14.2 191005 LeakDetectionFloatsConnection EL5131 Yes
15 103099 3”FilterClip PU4024 Yes

WL270Manual Page22Revision222017
103098 2”FilterClipforInLineFilter PU4025 Yes

16 191016 FilterBracket ST8206CN Yes
17.1
145011
1of2
Drainvalvecaponly(for5/16"&
1/4"size)
CT2028 Yes
17.2
145011
2of2
Drainvalvebodyonlyfor5/16" CT2031A Yes
17.3 NA
Drainvalvenutonly(for1/4"and
5/16")
CT2082 No
17.4 191049 RubberORingforDrainHole PL1293 Yes
17.5 NA DrainValveClamp5/16” CT2046 No
18 191050 HotWaterFaucetAssembly PL1260D Yes
19 191051
AmbientandColdFaucet
Assembly
PL1260E Yes
20 191018 UpperShelf ST8211 Yes
21 128058 SidePanelPlasticHandle PL1123 Yes

22 103083 UnitRubberFeet ST8016 Yes
WL270Manual Page23Revision222017
23 191001 InletSolenoidvalve120V PU4096 Yes
23.1 CU0001 SolenoidCushion CU0001 Yes
24 191020 InletSolenoidValveFixingBracket ST8214 Yes
25 191008
InletSolenoidValveJGAdaptor
1/4(CI320816S)
PU4104 Yes
26 191026 CoverofInletSV ST8233 Yes
27 191000 WireCondenserforGravityFed CO9040 No
28.1 103010 UVLampBallast110V/60Hz EL5006ACN Yes
28.2 191006 BallastWire EL5076 Yes
29 191022
BackPanelAccessPanelfor
ElectronicsService
ST8230 No

30.1 191090 SocketforPlugConnection EL5029 Yes

30.2 191015 GasketforPowerSocket ST8052 Yes

31.1 103014
FuseHolderandFuse120V/15A
withOneWire
EL5053 Yes

WL270Manual Page24Revision222017
31.2 103013 Fuse120V/15A EL5010 Yes
32 103008
RedCompressorandHeater
Switch
EL5004 Yes

33.1 191069 ColdTankThermostat CT2070A Yes

33.2 LP0326 ColdThermostatcoverLabel LP0326L0000 Yes
34 191017 SilverBackPanel ST8210 Yes
121210 UVLampRetainingThreadedNut PL1128 Yes
36 102350 UVLamp8WAssembly CT2083 Yes
36.1 191074 WireHarnessAssembly EL5079 Yes
37 102500 BlackORingforQuartzSleeve CT2006 Yes
38 101400 QuartzSleevefor8WLamp CT2002 Yes
39 191057 Siliconseal‐forInletPorttoTanks PU4109 Yes
WL270Manual Page25Revision222017
40 191039 WaterInlettoPorttoTanks PL1261 Yes
41 128006
HotTankFixingBracket400mmfor
1.6L
ST8120 Yes

42 191071
HotTankAssembly1.6Liter110V
500w
HT3028 Yes

42.1 191079
OverloadwithManualreset
95°C/203°F
HT3035 Yes

42.2 191078
HotTankThermostat
83°C/181°F
HT3034 Yes

42.3 126900
ThermostatandOverloadMetal
Cover
ST8289 Yes
42.4 192065 HotTankReplacementTube AK0067 Yes
43 191070 4LiterColdTank CT2068 No
44 191076 AirfilterSiliconCap PL1290 Yes
45 191052 Carbonairfilter PU4108 Yes
46 191056 ReservoirCoverSeal(Silicon) PU4099 Yes
WL270Manual Page26Revision222017
47 191004 WaterLevelControllerwithWire PU4100 Yes
48 191072 FloaterAssembly PU4097 Yes
48.1 191073 Floaterfitting&NutforGravity PU4098 Yes
48.2 191005 LeakDetectionFloat PU4100C Yes
49 191037 PlasticReservoir‐3Gallons PL1258 Yes
50 191042
MechanicalPushButtonfor
Ambient‐Green
PL1264 Yes
51 191041 MechanicalPushButtonforCold PL1263 Yes
52 191040 PushButtonforHot(Right)‐Red PL1262 Yes
53 191043 HotSafetyPushButton(Left)‐RedPL1265 Yes
54 191046 FaucetPushpin PL1268 Yes
55 191044 HotSafetyPushButtonpin PL1266 Yes
56 NA FaucetSpring PL1260A6 No
57 191047 FaucetBracket PL1269 Yes
58 191045 HotSafetyPushButtonSafetyLock PL1267 Yes
WL270Manual Page27Revision222017

59.1 191002 MainPCB EN6112 Yes
59.2 NA DisplayPCBCover PL1347 No

Not
Shown
191023 RORailBracket‐LeftHandSide ST8231A Yes
Not
Shown
191024 RORailBracket‐RightHandSide ST8231B Yes
Not
Shown
191074 WireHarnessAssembly EL5079 Yes
Not
Shown
103062
JGLLDPETube‐Blue8mm
JohnGuestP/NPE0806100MB
PU4014A Yes
Not
Shown
Purchase
fromJohn
Guest
JGLLDPETube‐Blue
O.D.1/4"JohnGuestP/NPE08BI
1000FB
PU4031A No
Not
Shown
107040 SiliconTube5/16"forHotWater PU4064 Yes
Not
Shown
191003 StraightConnectorforSiliconTubePU4101 Yes
Not
Shown
191058 SiliconElbowTube25*40 PU4110 Yes
Not
Shown
103007 PowerCord120V1825mm EL5001B Yes

WL270Manual Page28Revision222017
WL270WATERFLOWDIAGRAM

Storage
(
11.6L
)
LeakDetection
Sensor
WL270Manual Page29Revision222017
ADJUSTINGCOLDSETPOINT
Thecoldsetpointcanbeadjustedbyaccessingthecoldthermostat
adjustmentscrewUndertheDecalattherearoftheWL270Water
TreatmentSystem.
ThiswillNOTVoidtheWarrantyasthecurrentDecalstatesontheback
oftheWL270WaterTreatmentSystem.Thefactorysetpoint
is~5°C
(41°F)andisindicatedbythedotonsheetmetalaroundtheadjustment
screwandbehindthedecal.
Turningtheadjustmentscrewclockwiselowersthesetpointtemperature
andtherangeisapproximately20°Fthruthefullrangeofadjustment
(~7:00tothe~5:00positions).
Youshouldbeabletoturnthescrewfromthefactorysetpointof5°C
(41°F)(~12:00position)about45degreesclockwise(2:30onaclock)to
reducethesetpointtemperatureby6°Fandachievethe3536°Fsetting
youarelookingfor.

Trialthisbyadjustingandthenmeasurethewatertemperature1015
minutesafterthecompressorshutsoff(coldestpoint)toverifytheset
pointtemperature.

DonotadjustpasttheMaxColdPositionat3:00positiontoavoid
freezingthecoldtank.
FutureProductionincludesaColdTankAdjustmentStickerasshown.
WL270Manual Page30Revision222017
WL270ELECTRICALDIAGRAM
DANGER!HIGHVOLTAGEELECTRICALHAZARD.PCB(PrintedCircuitBoard)containsHigh
Voltage.Onlytrainedandqualifiedtechniciansshouldattemptlivetesting.
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19

WaterLogic WL270 User manual

Type
User manual

WaterLogic WL270 is multi-stage water filtration system capable of both heating and cooling of water to a temperature of your choice. The water filtration system includes an advanced ultraviolet (UV) lamp that disinfects the water by eliminating up to 99.99% of bacteria, viruses, and cysts. The filters remove chlorine, bad taste, odours and other contaminants, providing you with clean and healthy water. The system is designed to be easy to use and maintain, with an intuitive control panel and clear instructions.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI