Venmar 20-minute lighted push button for EVO5 500 HRV or EVO5 700 HRV HEPA User guide

Type
User guide

Venmar 20-minute lighted push button for EVO5 500 HRV or EVO5 700 HRV HEPA is a device that allows you to manually control the ventilation of your home. It can be used to increase the airflow in your home for a period of 20 minutes, which can be helpful for purging stale air or bringing in fresh air. The push button is lighted, which makes it easy to find in the dark. It can be easily mounted on a wall, and the installation process is simple and straightforward.

Venmar 20-minute lighted push button for EVO5 500 HRV or EVO5 700 HRV HEPA is a device that allows you to manually control the ventilation of your home. It can be used to increase the airflow in your home for a period of 20 minutes, which can be helpful for purging stale air or bringing in fresh air. The push button is lighted, which makes it easy to find in the dark. It can be easily mounted on a wall, and the installation process is simple and straightforward.

INSTALLATION AND USER GUIDE FOR 20-MINUTE LIGHTED PUSH-BUTTON TIMER
READ AND SAVE THESE INSTRUCTIONS
Always disconnect the unit before making any connections. Failure in disconnecting power could result in electric
shock or damage of the wall control or electronic module inside the unit.
WARNING
!
Cut a 2³/8 x 1³/8” hole in a wall, at a
convenient location for the push button.
Route the push-button cable from the
unit to this hole. See figure at right.
Temporarily place the push button over
the hole and mark both mounting screw
hole positions.
Remove the push button, drill both screw
holes (3/16” Ø) in wall and insert the wall
anchors (included).
Strip the end of the cable to access the wires.
NOTE: Although this is a 4-wire cable, only 3 of them will be
used for connection.
Strip the end of 3 wires. Connect wires to the terminals, no matter
the wire color: one wire to “OL, another one to OC’ and a last
one to “I’. Note which wire color has been chosen for each
terminal. See illustration below.
IOC
OL
20-MINUTE LIGHTED PUSH BUTTON
REAR VIEW
VE0268A
First wire
Fourth wire
(NOT USED)
Third wire
Second wire
V
C0125A
Ø 3/16”, typ.
Unplug the ventilation unit.
VC0126
Mount the push button to the wall.
Perform the electrical connection to the terminal connector of
the unit, as shown below. For more details, refer to the installation
manual of the ventilation unit.
NOTE: To avoid miswiring, refer to the notes about the color of
the wires taken on step .
NO C NC I OC OL Y R G B
20-MINUTE LIGHTED PUSH BUTTON
REAR VIEW
VE0269A
IOC
OL
Plug the ventilation unit and test the
push button by pressing on its center (A).
The ventilation unit will exchange air
with the outside on high speed for a
20-minute period, and the indicator (B)
will light up. To stop activation before
the end of the 20-minute cycle, press
one more time.
VC0127
A
B
Do not use the installation procedure leaflet enclosed in the shipping bag of the 20-minute lighted push button; use this one instead.
21350 rev. 01
  • Page 1 1

Venmar 20-minute lighted push button for EVO5 500 HRV or EVO5 700 HRV HEPA User guide

Type
User guide

Venmar 20-minute lighted push button for EVO5 500 HRV or EVO5 700 HRV HEPA is a device that allows you to manually control the ventilation of your home. It can be used to increase the airflow in your home for a period of 20 minutes, which can be helpful for purging stale air or bringing in fresh air. The push button is lighted, which makes it easy to find in the dark. It can be easily mounted on a wall, and the installation process is simple and straightforward.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI