American Dynamics AD2083/08 Installation And Operation Instructions Manual

Category
Security camera accessories
Type
Installation And Operation Instructions Manual

This manual is also suitable for

Model 2083/08
Code Translator
This manual describes the installation and operating procedures for the model 2083/08 Code Translator. The 2083/08 is an
interface unit used with American Dynamics Switching Systems. This unit translates codes to enable the use of all American
Dynamics Matrix Switchers with the 1261/1263/1265/1267 series of domes.
Installation and Operation Instructions
The software/firmware furnished with this equipment is confidential to and is copyrighted by SENSORMATIC ELECTRONICS
CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC.
The software/firmware is furnished to the purchaser under a license for use on a single system.
Information furnished by SENSORMATIC is believed to be accurate and reliable. However, no responsibility is assumed by
SENSORMATIC for its use; nor for any infringements of other rights of third parties which may result from its use. No license
is granted by implications or otherwise under any patent or patent rights of SENSORMATIC.
Copyright 1997 by Sensormatic. All rights reserved.
The installation of this product should be made by qualified
service personnel and should conform to all local codes.
QA301D
!
WW
WW
AA
AA
RR
RR
NN
NN
II
II
NN
NN
GG
GG
To reduce the risk of fire or shock hazard, do
not expose this product to rain or moisture.
AMERICAN
DYNAMICS
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVERS (OR BACK) .
NO USER-SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION
!
The lightning flash with arrowhead
symbol, within an equilateral
triangle, is intended to alert the
user to the presence of uninsulated
"dangerous voltage" within the
product's enclosure that may be of
sufficient magnitude to constitute a
risk of electric shock to persons.
The exclamation point within an
equilateral triangle is intended to
alert the user to the presence of
important operating and maintenance
(servicing) instructions in the
literature accompanying the product.
UU
UU
NN
NN
PP
PP
AA
AA
CC
CC
KK
KK
II
II
NN
NN
GG
GG
AA
AA
NN
NN
DD
DD
II
II
NN
NN
SS
SS
PP
PP
EE
EE
CC
CC
TT
TT
II
II
OO
OO
NN
NN
Unpack carefully. This is an electronic product and should
be handled as such. Compare the items received with the
packing list with your order.
Be sure to save:
1. The shipping cartons and insert pieces. They are the )
safest material in which to make future shipments of
the product.
2. The IMPORTANT SAFEGUARDS sheet.
3. These Installation and Operating Instructions.
MM
MM
AA
AA
II
II
NN
NN
TT
TT
EE
EE
NN
NN
AA
AA
NN
NN
CC
CC
EE
EE
User maintenance of this unit is limited to external cleaning
and inspection. For specific recommendations refer to the
IMPORTANT SAFEGUARDS sheet packaged with this product.
II
II
NN
NN
SS
SS
TT
TT
AA
AA
LL
LL
LL
LL
AA
AA
TT
TT
II
II
OO
OO
NN
NN
AA
AA
NN
NN
DD
DD
SS
SS
EE
EE
RR
RR
VV
VV
II
II
CC
CC
EE
EE
If you require information during installation of this
product or if service seems necessary, contact the
Sensormatic Repair and Service Department at (800)
442-2225. You must obtain a Return Authorization Number
and shipping instructions before returning any product for
service.
Do not attempt to service this product yourself. Opening or
removing covers may expose you to dangerous voltages or
other hazards. Refer all servicing to qualified personnel.
This equipment has been tested and
found to comply with Part 15 of the
FCC Rules.
Operation is subject to the
following two conditions: 1. This
device may not cause harmful
interference, and 2. This device
must accept any interference
received, including interference
that may cause undesired operation.
Table of Contents
Product Description...............................................................1
Installation.............................................................................1
Setup......................................................................................2
Connections...........................................................................3
Operation...............................................................................4
Typical Connections.................................................Appendix
PRODUCT DESCRIPTION
The 2083/08 Code Translator is used as an interface to
American Dynamics switching systems. The 2083/08 allows
retrofit or new installation of American Dynamic switchers
where the 1261/1263/1265/1267 series of dome camera control
systems are in place or desired.
When operating with the Control Code (B/W/S) interface the
2083/08 can control 64 cameras with 1650 Switchers, and 32
cameras with 2150 or 2350 Switchers. Multiple 2083/08 units
can be used to control 128 cameras with 1650 Switchers.
When using the Data Line interface the 2083/08 can control
512 cameras with 1995 or 2052 Systems, and 1024 cameras
with 2050 Systems.
FEATURES
UNIVERSAL MOUNT CABINET
LED POWER AND CODE INDICATORS
DIP SWITCH SELECTION FOR CAMERA GROUP
DIP SWITCH CONFIGURATION FOR BAUD RATE
SCREW TERMINAL WIRE CONNECTOR
INSTALLATION
This installation should be made by qualified service personnel
and should conform to all local codes. Safeguards must be
taken to avoid unintentional operation by employees and
maintenance personnel working about the premises, by falling
objects, by customers, by building vibration, and by similar
causes.
The universal cabinet of the 2083/08 Code Translator may be
surface or rack mounted in any convenient location with
adequate ventilation.
Rack Mounting
The 2083/08 is shipped with the mounting ears installed flush
with the front panel, and can be mounted to the front of a
standard 19-inch rack. The ears of the 2083/08 Code
Translator can be removed and reinstalled such that they are
flush with the rear panel. This allows the 2083/08 to be
mounted to the rear of a rack that is equipped with mounting
channels. For proper ventilation allow at least three feet (1 m)
from the rear of the racks to any wall and one EIA rack height,
1.75 inches (4.5 cm), between units in a rack.
Wall Mounting
The unit can be mounted to the wall by reinstalling the ears
perpendicular to the side of the unit. The bottom or top covers
can face toward the wall and the front or rear panel face
upwards.
1
DESCRIPTION
Figure 1 - 2083/08 Code Translator - Rear Panel
FRONT OR REAR PANEL
RACK MOUNTED WALL MOUNTED
RACK CHANNEL
TOP OR BOTTOM COVER
WALL
FRONT OR REAR PANEL
TOP COVER
MOUNTING EARS INSTALLED FLUSH
WITH THE FRONT OR REAR PANEL
120V
60Hz
T
+
R
+
R
T
T
T
R
+
R
T
+
R
+
R
T
T
+
T
R
+
R
T
+
R
+
R
T
T
+
T
R
+
R
T
+
R
+
R
T
T
+
T
R
+
R
GROUP
1
2
3
4
B W S
NO NC C
DATA LINE
IN
OUT
C
O
M
INPUT
OUTPUT
T
+
R
+
R
T
T
+
T
R
+
R
T
+
R
+
R
T
T
+
T
R
+
R
T
+
R
+
R
T
T
+
T
R
+
R
T
+
R
+
R
T
T
+
T
R
+
R
ABCD
ABCD
ABCD
ABCD
POWER
ALARM
CODE
S1
S2
S3
S4
Figure 2 - Mounting Options
SETUP
Camera Block Assignments
Four 8-position DIP switches (S1, S2, S3, and S4) are located
on the rear panel of the 2083/08, as shown in Figure 1, page 1.
The settings of these DIP switches determine the cameras
associated with the connectors in each of the four rear panel
groups (labeled GROUP 1, 2, 3, and 4). Each group is a block
of 250 cameras.
Table 1 shows the rear panel DIP switch settings as they
correspond to the camera number assignments. The active
positions of each switch are labeled A, B, C, and D on the rear
panel (see Figure 1).
Table 1 - S1, S2, S3, S4 SETUP
Video Input Switch Positions (0=OFF, 1=ON)
Camera #s A B C D
1-250 0000
251-500 0001
501-750 0010
751-1000 0011
1001-1024 0100
Baud Rate Selection
Two 8-position DIP switches (S5 and S6) are located on the
main PCB inside the 2083/08 (see Figure 3). Each DIP switch
has eight switch positions, numbered 1 through 8. The active
switch positions are used for setup of the communications
connectors baud rate.
The S5 DIP switch configures the baud rate for the RS-422
terminal pins of the dome interface connectors. For the
1261/1263/1265/1267 series domes, the baud rate must be set
to 9600; this is the factory default setting.
Table 2 shows the baud rate switch settings for S5.
Table 2 - S5 SETUP
(0=OFF, 1=ON)
Switch Positions
RS-422 Baud Rate 5 6
1200 0 0
2400 1 0
4800 0 1
9600 1 1
Set the unused switch positions of S5 to “0” (OFF). The S6
DIP switch is not used and all switch positions must be set to
"0" (OFF).
2
SETUP
S5
S6
FRONT
8
1
off
Figure 3 - Location of Internal DIP Switches
- CAUTION -
The following internal adjustments, requiring removal
of the top cover, will expose hazardous-voltage
components and allow access to dangerous electric
shock potentials. These adjustments should be made
only by qualified service personnel.
CONNECTIONS
Dome Interface Connectors
Eight 12-pin connectors on the rear of the 2083/08 Code
Translator panel are provided for transmitting RS-422 codes to
1261/1263/1265/1267 series domes. The transmit (T) signal
pins are labeled on each connector; the receive (R) pins are not
used. Each connector is supplied with a mating screw-terminal
connector (Figure 3) for attaching to external equipment.
Control Code Connector
The upper-right connector on the rear of the 2083/08 Code
Translator is a 12-pin connector. This is used to receive
Control Code signals from 1650, 2150, or 2350 switcher units
(B, W, and S lines). The mating screw-terminal connector is
shown below (Figure 5).
Connections on the above 12-pin connectors are easily made
by inserting signal and ground wires into the slots of the
mating connectors and tightening the hold down screws.
When all ties have been connected, insert the 12-pin mating
connectors into the rear panel. Use 18-AWG, twisted, shielded
pair cable, Belden 8760 or equivalent.
Data Line Connectors
Two DATA LINE BNC connectors are provided on the rear
panel, labeled IN and OUT. The IN BNC is used to receive
control data from the 1995, the 1996 CPU of 2050 systems, or
the 2052CPM of 2052 systems.
The OUT BNC is a loop-through connection to supply control
data to other units. This line must be terminated in 75 ohms,
either at the OUT connector if no other units are connected, or
at the last unit of the Data Line connection.
Use a good grade RG-59U video cable for all connections.
Note: When 1995 or 2050 systems with existing B/W/S
Control Code interfaces are used, they can be connected to
the 2083/08 Control Code Connector, as described in the
preceding paragraph (Figure 5).
See the Appendix for typical connections of the 2083/08 unit.
3
CONNECTIONS
HOLD DOWN SCREWS
THIS DIRECTION
INSERT CONNECTOR
T
+
R
+
R
+
+
T
R
R
T
T
Figure 4 - Mating Screw-Terminal Connector
HOLD DOWN SCREWS
INSERT CONNECTOR
THIS DIRECTION
B
W
S
B = BLACK
W = WHITE
S = SHIELD
Figure 5 - Control Code Mating Connector
OPERATION
Power Sources
DO NOT CONNECT THE UNIT TO A POWER SOURCE
UNTIL READY TO "POWER UP''. Make all connections to
the 2083/08 code input and interface connectors and set the
DIP switches prior to power up.
The 2083/08 Code Translator does not contain an On/Off
Switch. The socket outlet shall be located near the equipment
and shall be readily accessible. A green POWER LED
indicator located on the rear panel illuminates when power is
applied. The 120 V units are supplied with a pendant 3-wire
cord and plug for mating to the primary source outlet. The 230
V units are supplied with a Euro style IEC 320 type inlet. A
suitable detachable cord should be connected between the IEC
320 inlet and the power source. The cord should conform to all
national and local use code requirements. Two models are
available, depending on the power source:
AD2083/08 120VAC, 50/60 Hz
ADS2083/08X 230VAC, 50/60 Hz
The 2083/08 unit has fuse power protection. The fuse sizes for
replacement are:
120 V - 250 V, SB, 125 mA, 5 x 20 mm
230 V - 250 V, T, 125 mA, 5 x 20 mm
Operating Indicator
When the unit is receiving valid code, the green CODE LED,
on the rear panel, is illuminated. The LED stays lit for 5
seconds after code is removed. If this LED does not light, a
problem in the unit or its interconnection may be indicated.
Controlling 1261/1263/1265/1267 Domes
The 2083/08 supports the transmitted codes for
1261/1263/1265/1267 dome features. This includes the
standard American Dynamics keyboard functions for camera
Pan, Tilt, and Lens control.
The 1261/1263/1265/1267 series domes support the use of
auxiliary actions. The three dome auxiliary channels are
controlled via the normal keyboard AUX commands.
For those domes which implement preset capability, the
2083/08 supports keyboard commands for 64 presets per
receiver. For those domes which implement manual lens iris
control, the 2083/08 supports keyboard commands for
enabling/disabling automatic iris control.
All dome control keyboard commands supported by the
2083/08 are listed in Table 3.
4
OPERATION
IF YOU ENCOUNTER ANY PROBLEMS
OPERATING THIS UNIT, OR NEED ASSISTANCE,
CALL OUR TECHNICAL SUPPORT CENTER:
within the United States: 1-800-442-2225
outside the United States: (914) 624-7640
Table 3 - 1261/1263/1265/1267 Dome Commands
Dome Function Dome Action Keyboard Command
Pan, Tilt, Zoom, Focus, and Iris Functions Pan, Tilt, Zoom, Focus, and Iris Controls
Presets:
Set Preset 1 - 64 Saves camera position as preset 1 - 64 1 - 64 Set Shot
Goto Preset 1 - 64 Moves camera to preset position 1 - 64 1 - 64 Call Shot
Auxiliaries:
Set AUX 1 - 3 Activates Auxiliaries 1-3 1 - 3 AUX On
Clear AUX 1-3 Clears Auxiliaries 1-3 1 - 3 AUX Off
Other dome functions:
Disable Auto Iris Disables automatic control of lens iris * 70 Call Shot
Enable Auto Iris Enables automatic control of lens iris * 71 Call Shot
* These commands are applicable only for those domes which implement the manual iris control option. At
startup, the default is manual control of lens iris, if manual control is implemented.
APPENDIX
TYPICAL SYSTEM CONNECTIONS
1995 TO 2083/08
IN
120V
60Hz
T
+
R
+
R
T
T
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
GROUP
1
2
3
4
B W S NO NC C
DATA LINE
C
O
M
INPUT OUTPUT
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
ABCD
ABCD
ABCD
ABCD
POWER
ALARM
CODE
OUT
2083/08
1995
RST
LAN
1
IN OUT
LAN
2
IN OUT
PORT
10
PORT
9
PORT
8
PORT
7
PORT
6
PORT
5
PORT
4
PORT
3
PORT
1
PORT
2
COAX VIDEO CABLE
75 TERMINATION, IF NOT LOOPED
TO OTHER DATA LINE UNITS
A1
TYPICAL SYSTEM CONNECTIONS
1996 TO 2083/08
120V
60Hz
T
+
R
+
R
T
T
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
GROUP
1
2
3
4
B W S NO NC C
DATA LINE
IN
OUT
C
O
M
INPUT OUTPUT
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
ABCD
ABCD
ABCD
ABCD
POWER
ALARM
CODE
2083/08
COAX VIDEO CABLE
1
PORTS
PROG MON
DATA LINE
120V
60Hz
1
2
3
45678
9
10
2
1996
75 TERMINATION, IF NOT LOOPED
TO OTHER DATA LINE UNITS
A2
TYPICAL SYSTEM CONNECTIONS
2083/08 to 1261/1263/1265/1267 Domes
IN
120V
60Hz
T
+
R
+
R
T
T
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
GROUP
1
2
3
4
B W S NO NC C
DATA LINE
C
O
M
INPUT OUTPUT
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
ABCD
ABCD
ABCD
ABCD
POWER
ALARM
CODE
OUT
2083/08
T
+
R
+
R TTTR
+
R
+
1261/1263/1265/1267
DOME
14-pin CONNECTOR PLUG, J2
J2Pins:
3 - Transmit -
4 - Transmit +
123
4567
891011
121314
18 AWG SHIELDED TWISTED PAIR,
BELDEN 8760 OR EQUIVALENT
A3
TYPICAL SYSTEM CONNECTIONS
2150 TO 2083/08
BW S
BWS
18 AWG SHIELDED TWISTED PAIR,
BELDEN 8760 OR EQUIVALENT
120V
60Hz
T
+
R
+
R
T
T
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
GROUP
1
2
3
4
B W S NO NC C
DATA LINE
IN
OUT
C
O
M
INPUT OUTPUT
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
ABCD
ABCD
ABCD
ABCD
POWER
ALARM
CODE
2083/08
2150
RS232 PORTS
MONITORS
12
3
45
12
3
ALARMS
RELAY
KEYBOARDS
2345
2468101214161820222426283032
135791113151719212325272931
CAMERAS
-CODE-
120V
60Hz
BWS BWS BWS BWS
A4
TYPICAL SYSTEM CONNECTIONS
1650 TO 2083/08
120V
60Hz
T
+
R
+
R
T
T
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
GROUP
1
2
3
4
B W S NO NC C
DATA LINE
IN
OUT
C
O
M
INPUT OUTPUT
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
T
+
R
+
R
T
T
+
TR
+
R
ABCD
ABCD
ABCD
ABCD
POWER
ALARM
CODE
2083/08
W
B
S
BW S
18 AWG SHIELDED TWISTED PAIR,
BELDEN 8760 OR EQUIVALENT
1650
MONITOR
21
MONITOR
43
MONITOR
65
MONITOR
87
RS-232
12
34
J1
OUT
O
U
T
A
A
B
B
O
U
T
O
U
T
A
A
B
B
O
U
T
O
U
T
A
A
B
B
O
U
T
O
U
T
A
A
B
B
O
U
T
A5
Declaration of Conformity
Manufacturer:
Sensormatic CCTV Systems Division
Manufacturer’s Address:
Sensormatic CCTV Systems Division Sensormatic CCTV Systems Division
1 Blue Hill Plaza 600 Bradley Hill Road
Pearl River, New York, 10965 USA Blauvelt, NY 10913 USA
Sensormatic Electronics Corporation Sensormatic Electronics Corporation (IRL) LTD
State Rd. 110 Km 5.8 Melbourn Road, Bishopstown
Poblado San Antonio Cork, Ireland
Aguadilla P.R. 00690
Declares, that the product(s) listed below:
Name/Type: Code Translator
Model Number: ADS2083/08X
complies with the EMC Standards EN55022 (Class B), EN50082-1, and also complies with the
following safety standard: EN60950.
Additional information:
These products herein, comply with the requirements of the EMC Directive 89/336/EEC, and with the Low Voltage
Directive (LVD) 73/23/EEC. The equipment was tested in a typical configuration.
Pearl River, NY, USA 14 February, 1997
Ed Thompson
Engineering Manager
European Contact: Sensormatic GmbH
Am Schimmersfeld 7,
40880 Ratingen, Germany
SPECIFICATIONS
Electrical Ratings: AD2083/08 - 120VAC, 50/60 Hz, 8 W
ADS2083/08X - 230VAC, 50/60 Hz, 100 mA
Mounting: Desktop or rack-mount
Weight: 7 lbs. (3.2 Kg)
Dimensions: 3.5" H x 17" W x 7.75" D (89 x 432 x 197 mm)
An American Dynamics Product
Designed and built by
Sensormatic CCTV Systems Division
One Blue Hill Plaza
Pearl River, New York, 10965
Business: (914) 624-7600
Technical Support Center: 1-800-442-2225
FAX: (914) 624-7685
8000-0927-01 OP2083-08A
February, 1997 Printed in USA
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20

American Dynamics AD2083/08 Installation And Operation Instructions Manual

Category
Security camera accessories
Type
Installation And Operation Instructions Manual
This manual is also suitable for

Ask a question and I''ll find the answer in the document