  • Hello! I am an AI chatbot trained to assist you with the Danfoss SpeedUp Eco - Strongboard Carpet User guide. I’ve already reviewed the document and can help you find the information you need or explain it in simple terms. Just ask your questions, and providing more details will help me assist you more effectively!
Application sheet
SpeedUp Eco
Carpet
Strongboard carpet
1
2
3
4
5
1 Carpet ≥ 5 mm
2 Strongboard carpet 10 mm
3 SpeedUp Eco heat panel + FH composite pipe 30 mm
4 Support batten (30mm)
5 Load bearing panel ≥ 15 mm
6 Wood bre insulation - additional insulation 30 mm
7 SpeedUp Eco perimeter insulation
8 If necessary moisture barrier
Floor nish ≥ 5 mm Carpet
Construction height ≥ 90 mm Height including oor nish
Weight ~ 35 kg / m² Weight including oor nish
Thermal resistance R 1,26 m²K / W The minimum thermal resistance requirement of DIN EN 1264 is
fullled. For water table ≤ 5 m the R-value must be increased.
Thermal transmission coecient U 0,70 W / m²K In renovations and building extensions up to 50 m² U-value = 0.5
W/m²K must be maintained.
Always follow the planning data.
Design load ≤ 2,0 kN / m²
Point load (≥ 20 cm²) ≤ 1,0 kN Sum point load ≤ design load; please notice special heavy ob-
jects (aquaria etc.)
Impact subsonic noise reduction 22 dB Test value according to DIN ISO 140-8; applies to concrete slabs
thicker than 12 cm (DIN 4109: m’ > 276 kg/m²)
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Requirements & special features
A level, smooth and structurally sound surface is necessary for full surface contact with
the heating elements (elevated requirements according to DIN 18202 Table 3, row 4).
Structural sealing according to DIN 18195 must be placed beneath the oor panel in
case of structures facing the ground, and otherwise on the unnished oor. Strongboard
Carpet and synthetics must be primed after it is layed. If necessary, provide construction
with additional sealing against moisture from below (vapour barrier/seal). Observe all
installation instructions and manufacturer’s instructions.
Additional insulation
30 mm wood bre insulation 150 kPa, alternatively: 20 mm GUTEX Thermosafe wd = 50
kPa. Renovation: 50 mm wood bre insulation 150 kPa, WLG 050 / 40 mm wood bre
insulation 50 kPa, WLG 040.
Construction
According to EnEV, EN 1264, DIN 1055, 4108 and 18202
Construction number 91
Technical Data Floors/ceilings facing unheated rooms or the ground