Tile / Natural Stone
1 Tile / natural stone incl. adhesive ≥ 12 mm
2 Strongboard Tile and Laminate 5 mm
3 SpeedUp Eco heat panel + FH composite
pipe
30 mm
4 Support batten (30 mm)
5 SpeedUp Eco perimeter insulation
6 Moisture barrier (if necessary)
Technical Data
Floor finish ≥ 8 mm Tile dimensions min. 10 x 10 cm; max. 40 x 60 cm.
Natural stone thicknesses from 10 mm; Grout
width 3 mm
Construction height ≥ 47 mm Height including floor finish
Weight ~ 49 kg/m² Weight including floor finish
Thermal resistance (R) 0.75 m²K/W The minimum thermal resistance requirement of
EnEV is fulfilled
Thermal transmission
coefficient (U)
1.09 W/m²K
Distribution load ≤ 2.0 kN/m²
Point load (≥ 20 cm²) ≤ 2.0 kN Sum point load ≤ design load; please notice
special heavy objects (aquaria etc.)
Impact subsonic noise
reduction
19 dB Test value according to DIN ISO 14-8; applies to
concrete slabs thicker than 12 cm
Application area Residential spaces, hallways and attic spaces in residential buildings and hotel
rooms. Corresponds to categories A1, A2 and A3 of DIN 1055-3.
Requirements &
special features
A level, smooth and structurally sound surface is necessary for full surface
contact with the heating elements (elevated requirements according to DIN
18202 Table 3, row 4). Wooden joist floor, free from twist effects, free of
deflection Strongboard is only approved for use with Danfoss components. Lay
tiles using the combined method with Mapei adhesive and Elastorapid (see
installation instructions). Observe all installation instructions and
manufacturer’s instructions.
Additional
insulation
This construction applies to residential partition slabs between rooms at the
same temperature. No additional insulation is necessary. See “Overview of
maximum additional insulation” with regard to allowable equalisation
insulation.
Construction According to EnEV, EN 1264, DIN 1055, 4108 and 18202.
Construction number 35
Application Sheet
SpeedUp Eco - Strongboard for Tile and Laminate
Danfoss Heating Solutions VACSF302 © Danfoss 11/2010 1