Danfoss SpeedUp Eco - Direct load User guide

Type
User guide

Danfoss SpeedUp Eco - Direct load

Danfoss SpeedUp Eco - Direct load is a heating system designed for use in residential and commercial spaces, offering a range of features for efficient and comfortable heating.

The system consists of heat panels and composite pipes that work together to provide even heat distribution, with the heat panels featuring a low profile of only 30mm for easy installation, making it a suitable choice for renovations or new constructions.

The system boasts a high thermal resistance of 1.35 m²K/W, ensuring energy efficiency. Additionally, it provides impact subsonic noise reduction of 21 dB, contributing to a quieter living environment.

Danfoss SpeedUp Eco - Direct load

Danfoss SpeedUp Eco - Direct load is a heating system designed for use in residential and commercial spaces, offering a range of features for efficient and comfortable heating.

The system consists of heat panels and composite pipes that work together to provide even heat distribution, with the heat panels featuring a low profile of only 30mm for easy installation, making it a suitable choice for renovations or new constructions.

The system boasts a high thermal resistance of 1.35 m²K/W, ensuring energy efficiency. Additionally, it provides impact subsonic noise reduction of 21 dB, contributing to a quieter living environment.

Application sheet
SpeedUp Eco
Massive wooden planks on battens
Direct load
1
2
3
4
5
1 Wooden planks ≤ 22 mm
2 SpeedUp Eco heat panel + FH composite pipe 30 mm
3 Support batten (30mm)
4 Wood bre insulation 150 kPa 30 mm
5 SpeedUp Eco perimeter insulation
6 If necessary construction sealing
Floor nish ≤ 22 mm Massive wooden planks or parquet
Construction height ≤ 72 mm Height including oor nish
Weight ~ 26 kg / m² Weight including oor nish
Thermal resistance R 1,35 m²K / W The minimum thermal resistance requirement of DIN EN 1264 is
fullled.
Thermal transmission coecient U 0,66 W / m²K If the architectural design species better thermal insulation, this
must be taken into account.
Design load ≥ 2,0 kN / m²
Point load (≥ 20 cm²) ≥ 2,0 kN Sum of point loads not exceeding rated design load; particularly
heavy objects (such as aquariums and bathtubs) must be consid-
ered separately.
Impact subsonic noise reduction 21 dB Test value according to DIN ISO 140-8; applies to concrete slabs
thicker than 12 cm (DIN 4109: m’ > 276 kg/m²)
Application area
Residential spaces, hallways and attic spaces in residential buildings and hotel rooms.
Corresponds to categories A1, A2 and A3 of DIN 1055-3. Oce spaces, hallways in oce
buildings, medical oces, stations and spaces with human occupancy, and commercial
spaces with oor areas up to 50 m² in residential or oce buildings. Corresponds to
categories B1, D1 and D2 of DIN 1055-3.
Requirements & special features
A level, smooth and structurally sound surface is necessary for full surface contact with
the heating elements (elevated requirements according to DIN 18202 Table 3, row 4). The
R value must be increased if the groundwater level is less than or equal to 5 m. A U value
not exceeding 0.5 W/m²K must be maintained in existing buildings and additions with
areas up to 50 m². If necessary, protect oorboards and prefabricated parquet against
moisture penetration from below according to the manufacturer’s instructions (vapour
barrier). Observe all installation instructions and manufacturers instructions.
Additional insulation
30 mm wood bre insulation 150 kPa; alternative: 20 mm Gutex Thermosafe wd ≥ 50 kPa.
Existing buildings: wood bre insulation 60 mm 150 kPa, WLG 050; alternatively 40 mm
50 kPa, WLG 040.
Construction
According to EnEV, EN 1264, DIN 1055, 4108 and 18202
Construction number 89
Technical Data Floors/ceilings facing unheated rooms or the ground
6
© Danfoss 11/2008
VA.CS.M1.02
Danfoss HES
  • Page 1 1

Danfoss SpeedUp Eco - Direct load User guide

Type
User guide

Danfoss SpeedUp Eco - Direct load

Danfoss SpeedUp Eco - Direct load is a heating system designed for use in residential and commercial spaces, offering a range of features for efficient and comfortable heating.

The system consists of heat panels and composite pipes that work together to provide even heat distribution, with the heat panels featuring a low profile of only 30mm for easy installation, making it a suitable choice for renovations or new constructions.

The system boasts a high thermal resistance of 1.35 m²K/W, ensuring energy efficiency. Additionally, it provides impact subsonic noise reduction of 21 dB, contributing to a quieter living environment.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI