DANLERS TLSW A20 Installation guide

Type
Installation guide

This manual is also suitable for

DANLERS TLSW A20 ILM

This device is a time lag switch with an illuminated button. It can be used to control lighting, fans, or other electrical devices. The time lag can be set between approximately 2 and 20 minutes, which makes it ideal for a variety of applications. For example, you could use it to turn off the lights in a room after you leave, or to turn on a fan after a set period of time.

The TLSW A20 ILM is easy to install and use. It has two terminal blocks on the reverse, which should be connected as follows:

  • Block 1:
    • L: Live input
    • N: Neutral input
    • SL: Switched Line output

DANLERS TLSW A20 ILM

This device is a time lag switch with an illuminated button. It can be used to control lighting, fans, or other electrical devices. The time lag can be set between approximately 2 and 20 minutes, which makes it ideal for a variety of applications. For example, you could use it to turn off the lights in a room after you leave, or to turn on a fan after a set period of time.

The TLSW A20 ILM is easy to install and use. It has two terminal blocks on the reverse, which should be connected as follows:

  • Block 1:
    • L: Live input
    • N: Neutral input
    • SL: Switched Line output
Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIRoccupancyswitches•Daylightlinkeddimmers•Manualhighfrequencydimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers•Heating,ventilationandair-conditioningcontrols•Bespoke/O.E.M.products
Please call for more information or a free catalogue, or visit our website.
ThisproductconformstoBSEN60669-2-1andBSEN55015.
Pleaseensurethemostrecenteditionoftheappropriatelocalwiringregulationsareobserved
andsuitableprotectionisprovidede.g.a10ampcircuitbreakerandvoltagesurgeprotection.
Pleaseensurethatthisdeviceisdisconnectedfromthesupplyifaninsulationtestismade.
Thisproductiscoveredbyawarrantywhichextendsto5yearsfromthedateofmanufacture.
Precautions and Warranty
Plated time lag switches (3-wire versions)
TLSW A20 TLSW A120
TLSW A20 ILM TLSW A120 ILM
DANLERS3-wireplatedtimelagswitchesneedaneutralconnection.
Wherenoneutralispresenta2-wireplatetimelagswitchshouldbe
used(TLSW10).Thewallboxmustofatleast16mmdeep.
Ashortpresswillswitchtheloadonanditwillswitchoffautomatically
afterthetimelagperiodhasexpired.
The time lag on the TLSW A20 products can be set between
approximately 2 and 20 minutes.
The time lag on the TLSWA120 products can be set to between
approximately 12 and 120 minutes (2 hours).
Thebuttonontheilluminatedversions(TLSWA20ILMandTLSW
A120ILM)islitatalltimes(whentheloadisonoroff).
The load can be switched on from other locations by connecting
thesedevicesinparallelorbyconnectingDANLERSmatchingslave
switches,availableasbothaplatedsinglegangslave(SS1SL)and
atwogangslave(SS2SL).
Theseswitchescanonlybeconnectedtoa230V50HzACsupply.
Theycanswitchupto6amps(1500W)of:
• Fluorescentlamps,eitherhighfrequencyorswitchstart
•Incandescentormainshalogenlamps(recommendedwithintegralsafetyfuse)
•Electronicorwirewoundtransformers.
Theycanalsoswitchupto:
•2amps(500W)ofCFL,2Dlamps,LEDDriversandLEDlampsandttings.
•1amp(250W)ofFansorMetalHalidelamps.
Minimumload2Wresistive,suitableformostenergysavinglamps,
LEDsandemergencyttings.
For larger loads they can be used to operate a contactor.
14/04/15 INS984 TLSW Ax20
Troubleshooting
Slave switch does not operate the time lag switch:
•EnsureonlyDANLERSslaveswitchesareused.
•Ensureslavewiringislessthan10mlong.
Does not work with existing 2-way switches:
•Timelagsandslavescanusethewiringof2-wayswitching
 circuits,butnotmixedwith2-wayswitches.
There is no Neutral connection available:
•DANLERS2-wire,TLSW10(ILM),shouldbeusedinstead.
Loading
Installation procedure
1.Pleasereadthesenotescarefullybeforecommencingwork.
Incaseofdoubtpleaseconsultaqualiedelectrician.
Makesurethepowerisisolatedfromthecircuit.
Ifafourlugmetalbackboxistobeused,thetopandbottomlugs
mustberemoved
2.TheTLSWAx20(ILM)hastwoterminalblocksonthereverse,which
should be connected as:
 Block1 L Liveinput
N Neutral input
 SL SwitchedLineoutput
 Block2 PushButton Forconnectiontoslaveswitch(es).†
Must not be connected to the mains.
3.Existingtwo-waystrapperlinescanusuallybeusedtoconnect
thesetimelagswitchesinparallelortoconnectslaveswitch(es),
asshowninthewiringdiagramsopposite.
4.Thetimelagisadjustedviaaspindle(seeillustrationbelow)by
insertinganarrow(at)screwdriverthroughtheholelocatedon
thebottomedgeofthedevice:
TLSW A20 (ILM) TLSW A120 (ILM)
Notes:
†ThetwoterminalsonDANLERSslaveswitchesarelabelledas:
PlatedSlaveswitches: PushButton
GridSlaveswitches: L,S
Ifgridslaveswitchesareusedwithplatedtimelagswitches,the
LandSterminalsmustbeconnectedonlytothePushButton
terminalsonthetimelagswitch,nottolive.
Typical wiring diagrams
1-way TLSW x20 (ILM)
load
L
N
230 VAC
SL
Push
Button
L
TLSW x20 (ILM)
N
TIME
2
mins
20
mins
APPROXIMATE
SETTINGS
10 mins
Example of a typical 2-way circuit
load
LN
230 VAC
Multi-way TLSW x20 (ILM) with slave switches
LN
230 VAC
load
SL
L
Push button
Slave
SwitchSlave
Switch
TLSW x20
(ILM)
Unused existing wire
terminate safely
Push button SS 1SL
SS 1SL
N
Multi-way TLSW x20 (ILM) in parallel
LN
230 VAC
load
SL
LL SLSL
L
Push buttonPush button Push button
TLSW x20
(ILM)
TLSW x20
(ILM)TLSW x20
(ILM)
NNN
TIME
12
mins
120
mins
APPROXIMATE
SETTINGS
60 mins
  • Page 1 1
  • Page 2 2

DANLERS TLSW A20 Installation guide

Type
Installation guide
This manual is also suitable for

DANLERS TLSW A20 ILM

This device is a time lag switch with an illuminated button. It can be used to control lighting, fans, or other electrical devices. The time lag can be set between approximately 2 and 20 minutes, which makes it ideal for a variety of applications. For example, you could use it to turn off the lights in a room after you leave, or to turn on a fan after a set period of time.

The TLSW A20 ILM is easy to install and use. It has two terminal blocks on the reverse, which should be connected as follows:

  • Block 1:
    • L: Live input
    • N: Neutral input
    • SL: Switched Line output

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI