DANLERS DSSGD CB400W is a soft-start grid dimmer, designed to fit into Crabtree grid plates. It allows for smooth switching and dimming of various types of lighting, including incandescent lamps, mains halogen lamps, dimmable compact fluorescent or LED lamps, and dimmable electronic transformers. With a maximum load capacity of 400W, it can handle a substantial amount of lighting. The soft-start feature gradually increases the output voltage, which can extend the lifespan of lamps, especially low voltage ones.

DANLERS DSSGD CB400W is a soft-start grid dimmer, designed to fit into Crabtree grid plates. It allows for smooth switching and dimming of various types of lighting, including incandescent lamps, mains halogen lamps, dimmable compact fluorescent or LED lamps, and dimmable electronic transformers. With a maximum load capacity of 400W, it can handle a substantial amount of lighting. The soft-start feature gradually increases the output voltage, which can extend the lifespan of lamps, especially low voltage ones.

Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
E-mail: [email protected] Web: www.danlers.co.uk
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Also available from DANLERS
• PIRoccupancyswitches•Daylightlinkeddimmers•Manualhighfrequencydimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers•Heating,ventilationandair-conditioningcontrols•Bespoke/O.E.M.products
Please call for more information or a free catalogue, or visit our website.
ThisproductconformstoBSEN60669-2-1andBSEN55015:1993
Pleaseensurethemostrecenteditionoftheappropriatelocalwiringregulationsareobserved
andsuitableprotectionisprovidede.g.6ampsovercurrent,1kVovervoltage.Pleaseensure
thatthisdeviceisdisconnectedfromthesupplyifaninsulationtestismade.
Thisproductiscoveredbyawarrantywhichextendsto5yearsfromthedateofmanufacture.
Precautions and Warranty
Soft Start Grid Dimmers
DSSGD MK400W DSSGD CB400W DSSGD EU400W
DANLERS‘leadingedge’softstartdimmersaresuitableforttinginto
MKGridPlus(MK),Crabtreegrid(CB)andEurodataplates(EU).
Thesoftstartfeatureelectronicallyrampsup(virtuallyindiscernible)
theoutputvoltagewhichcangreatlyincreaselamplife,particularly
forlowvoltagelamps.
Ashortpresswillswitchtheloadofforrestoreitsoftlytoitsprevious
setting.Aholdingpresswilldimtheloadupanddowninturn.
Theloadcanbeswitchedanddimmedfromseverallocationsbyusing
DANLERSmatchingslaveswitches.Ordercodes:SSGSMK,SSGS
CBandSSGSEU.
DANLERSsoftstartgriddimmerscancontrol40-400Wof:
• Incandescentlamps
• Mainshalogenlamps(mustincludeintegralsafetyfuse)
• MostdirectlydimmablecompactuorescentorLEDlamps
• Dimmableelectronictransformers(max.6transformers).
Theyarealsosuitableforcontrolling40-250Wof:
•Dimmable,wirewound,toroidaltransformers.
Themaximumtotalloadforgridplatesisasfollows:
 Numberofgangs Maximumloadwattage
• 2 630W
• 3or4 1000W
• 6,8,9or12 1000Wperrow
• 8or24 1200Wperrow
If the load is less than 40W resistive e.g. when dimming compact
uorescentthelampmayicker.Theloadcanbeaugmentedusing
aloadresistorconnectedatthemainslampttingoracrosstheinput
tothelowvoltagetransformer.Orderas:RESLOADE.
05/12/13 INS920 DSSGD400W
Loading
Lamp dims up and down constantly:
• Ensureslaveswitchhasbeenused,nottwowayswitch
• Buttonpressedtoohardandjammed.Releasebutton
• Slavewiringmorethan10mlong.Useshieldedortwistedwiring.
Load cannot be controlled by slave switch:
• EnsureonlyDANLERSslaveswitchesareused.
Load can only be switched off or dimmed down by slave switch:
• EnsurethattheslaveswitchisconnectedtoLandnottoV.
Lamp ickers:
• Minimumloadnotreached.FitRESLOADE
• Electronictransformerunstable.Trytting:RESLOADE
• Loadincompatiblewith‘leadingedgedimming’
Please consider using DANLERS Quiet Grid dimmer.
Soft start dimmer fails after some time:
• Halogenlamp,notincorporatinganintegralsafetyfuse,failed.
Soft start dimmer ‘buzzes’:
• Thiscanoccurwith‘leadingedge’dimmers,
Please consider using DANLERS Quiet Grid dimmer.
Soft start dimmer gets warm:
• Thiscanoccurwithdimmers,especiallywhencontrollinglargeloads.
Troubleshooting
Thesoftstartgriddimmersneedthefollowingdepthwallboxes:
• DSSGDMK400W 35mm(minimum)
• DSSGDCB400W 40mm(minimum)
• DSSGDEU400W 35mm(minimum)
Installation procedure
1.Pleasereadthesenotescarefullybeforecommencingwork.
Incaseofdoubtpleaseconsultaqualiedelectrician.
Makesurethepowerisisolatedfromthecircuit.
2.Thesoftstartgriddimmershouldbeconnectedas:
L Live
V Variable (dimmed) output
S Slaveconnection
3.Typicalwiringdiagramsareshownopposite.
4.Existingtwo-waystrapperlinescanusuallybeusedtolinktheLive
andSlavewiresfromthesoftstartdimmertotheslaveswitch(es).
5.ThetwoterminalsonDANLERS Slave Switches are labelled as:
GridSlaveswitches L,S
PlatedSlaveswitches Pushbutton
The terminal connections are interchangeable.
6.Oncethewiringhasbeencompletedandveried,switchonthesupply
and test the operation.
Grid wall box depths Typical wiring diagrams
Example of a typical 2-way circuit
load
LN
230 VAC
Multi-way switching and dimming
(lights can be switched and dimmed from any position)
LN
230 VAC
load
V
LL
S
SS
L
Slave
Switch Slave
Switch
Soft start
dimmer
Unused existing wire
terminate safely
1-way switching and dimming
load
L
N
230 VAC
V
Soft Start
Grid Dimmer
S
Optional RESLOADE,
Augmenting load.
See minimum load.
L
  • Page 1 1
  • Page 2 2

DANLERS DSSGD CB400W Installation guide

Type
Installation guide
This manual is also suitable for

DANLERS DSSGD CB400W is a soft-start grid dimmer, designed to fit into Crabtree grid plates. It allows for smooth switching and dimming of various types of lighting, including incandescent lamps, mains halogen lamps, dimmable compact fluorescent or LED lamps, and dimmable electronic transformers. With a maximum load capacity of 400W, it can handle a substantial amount of lighting. The soft-start feature gradually increases the output voltage, which can extend the lifespan of lamps, especially low voltage ones.