Installation notes
DANLERS Limited, Vincients Road, CHIPPENHAM, Wiltshire, SN14 6NQ, UK.
Telephone: +44 (0)1249 443377 Fax: +44 (0)1249 443388
Company Registered Number 2570169 VAT Registration Number 543 5491 38
Products available from DANLERS
• PIRoccupancyswitches•Daylightlinkeddimmers•Manualhighfrequencydimmers
• Photocells • Radio remote controls • Time lag switches • Outdoor security switches
• Dimmers•Heating,ventilationandair-conditioningcontrols•Bespoke/O.E.M.products
Please call for more information or a free catalogue, or visit our website.
ThisproductconformstoBSEN60669-2-1andBSEN55015.
Pleaseensurethemostrecenteditionoftheappropriatelocalwiringregulationsareobserved
andsuitableprotectionisprovidede.g.a10ampcircuitbreakerandvoltagesurgeprotection.
Pleaseensurethatthisdeviceisdisconnectedfromthesupplyifaninsulationtestismade.
Thisproductiscoveredbyawarrantywhichextendsto5yearsfromthedateofmanufacture.
Precautions and Warranty
Plated time lag switches (3-wire versions)
TLSW A20 TLSW A120
TLSW A20 ILM TLSW A120 ILM
DANLERS3-wireplatedtimelagswitchesneedaneutralconnection.
Wherenoneutralispresenta2-wireplatetimelagswitchshouldbe
used(TLSW10).Thewallboxmustofatleast16mmdeep.
Ashortpresswillswitchtheloadonanditwillswitchoffautomatically
afterthetimelagperiodhasexpired.
The time lag on the TLSW A20 products can be set between
approximately 2 and 20 minutes.
The time lag on the TLSWA120 products can be set to between
approximately 12 and 120 minutes (2 hours).
Thebuttonontheilluminatedversions(TLSWA20ILMandTLSW
A120ILM)islitatalltimes(whentheloadisonoroff).
The load can be switched on from other locations by connecting
thesedevicesinparallelorbyconnectingDANLERSmatchingslave
switches,availableasbothaplatedsinglegangslave(SS1SL)and
atwogangslave(SS2SL).
Theseswitchescanonlybeconnectedtoa230V50HzACsupply.
Theycanswitchupto6amps(1500W)of:
• Fluorescentlamps,eitherhighfrequencyorswitchstart
•Incandescentormainshalogenlamps(recommendedwithintegralsafetyfuse)
•Electronicorwirewoundtransformers.
Theycanalsoswitchupto:
•2amps(500W)ofCFL,2Dlamps,LEDDriversandLEDlampsandttings.
•1amp(250W)ofFansorMetalHalidelamps.
Minimumload2Wresistive,suitableformostenergysavinglamps,
LEDsandemergencyttings.
For larger loads they can be used to operate a contactor.
14/04/15 INS984 TLSW Ax20
Troubleshooting
Slave switch does not operate the time lag switch:
•EnsureonlyDANLERSslaveswitchesareused.
•Ensureslavewiringislessthan10mlong.
Does not work with existing 2-way switches:
•Timelagsandslavescanusethewiringof2-wayswitching
circuits,butnotmixedwith2-wayswitches.
There is no Neutral connection available:
•DANLERS2-wire,TLSW10(ILM),shouldbeusedinstead.
Loading