Skov Replacement of load cells/amplifier Technical User Guide

Type
Technical User Guide
DOL 99B Feed Weigher 603664
Product description
This is a load cell or a load cell amplifier for a DOL 99B feed weigher.
Installation guide
Replace load cell
1. Mount the new load cell.
2. Tighten the nut. Then loosen the nut ¼ turn. See figure 1.
3. Connect the new wire. See wire colors in the table.
4. Carry out offset adjustment and calibration. See the section below.
Figure1: Mounting the load cell
Wire colors load cell variants
HBM HBM load cell Zemic load cell
U1 0 V - Blue Green Black
U2 V out + Brown Brown Green
U3 V out - White/Yellow Yellow White
U4 10 V + Black White Red
U5 Shield Shield Green-yellow shield Transparent shield
U6
U7
U8
U9
U10
U11 Brown
U12 Blue
Technical User Guide
Replace load cell amplifier
1. Replace the load cell amplifier
2. If the weigher is an upgraded DOL 99 or DOL 99-2 and it uses load cells with only one wire to the connec-
tion box, wire on the amplifier is cut. See figure 2, item (D) Selection of load cell type.
3. Carry out offset adjustment and calibration. See the section below.
(A) Calibration figures
(B) Adjustment screw (offset)
(C) Load cell amplifier
(D) Selection of load cell type
(E) Connection of low current
(F) Connection of high-voltage current
Figure2:
Offset adjustment
The drum is empty.
1. Connect a voltmeter between terminals U7 (+) and U9 (-).
2. Adjust the screw with small screwdriver until the voltage is 1.0 V DC (See fig. 2, item (B) Adjustment
screw).
Calibration
Also see Technical Manual for the controller.
SKOV A/S• Hedelund 4 •Glyngøre• DK-7870 Roslev
Tel. +45 72 17 55 55 • www.skov.com • E-mail: [email protected]
  • Page 1 1
  • Page 2 2

Skov Replacement of load cells/amplifier Technical User Guide