Focal Point Seem 4 LED Direct/Indirect FSM4BW Installation guide

Type
Installation guide
IS0704 Rev. B 2023 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 3
seem 4 led direct/indirect wall mount
FSM4BW
focal point
U -
individUal
S -
Start of rUn
i -
intermediate
e -
end of rUn
individUal
(Start of rUn)
Luminaires must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
configUrationS are rUn Specific, pleaSe conSUlt factory drawingS before beginning inStallation.
key
See additional
inStrUctionS
power off power on attention
intermediate
(end of rUn)
1
2' housing 3' & 6' housings
LOCATE J-BOX CENTER & INSTALL (J-BOX BY OTHERS. 4"x2" handy box.)
12.10" 18.10"
4', 7' & 8' housings 5' housing
luminaire outline
luminaire outline
luminaire outline
luminaire outline
24.10" 30.10"
2.62"
2.62"
2.62"
4.52"
4.52"
4.52"
4.52"
2.62"
individUal inStallationS follow StepS 1-3, 5 & 11
Flush Lens Down
Flush Lens Up Pop-Up Lens
0.5" Pop-Down Flush Lens Down
Pop-Up Lens
2
(FASTENERS BY OTHERS)
partS liStS
joiner
(72010)
(6-32 X 5/16 pan-Head
macHine Screw)
SHipped inStalled
joiner aSSembly
(a40688)
top bracket
joiner
(a38740-01)
bottom bracket
joiner
(a42759-01)
+
+
-
-
117
23 INSTALL REMAINING RAILS.
REMOVE END SECTION FROM
LAST RAIL IN RUN.
(FASTENERS BY OTHERS)
5
A
B
C116
AVOID ALL CONTACT WITH LED SURFACE,
LEDS ARE EASILY DAMAGED!
IS0704 Rev. B 2023 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 3
Luminaires must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
12
114
make electrical connections
WIRE NUTS FOR
DIMMING WIRES
BY OTHERS
11
10 X2
11 X2
8119
driver Service
2
AVOID ALL CONTACT WITH LED SURFACE,
LEDS ARE EASILY DAMAGED!
111
AVOID ALL CONTACT WITH LED SURFACE,
LEDS ARE EASILY DAMAGED!
Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls
and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC
is prohibited.
IS0704 Rev. B 2023 ©Focal Point, LLC 4141 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 3
113
EMERGENCY
SEE BATTERY MANUFACTURER
INSTRUCTIONS
A
emergency battery
maXimUm moUnting HeigHt: 17.75’
X4
ASYMMETRIC LENS
DISTRIBUTION DIRECTION
ASYMMETRIC ROOM FILL
LENS DISTRIBUTION
DIRECTION
12 12
  • Page 1 1
  • Page 2 2
  • Page 3 3

Focal Point Seem 4 LED Direct/Indirect FSM4BW Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document