Focal Point Skydome LED 2', 3', 4' - Recessed FSDL-22/33/44 Installation guide

Type
Installation guide
IS0511 REV. C 2022 ©Focal Point, LLC 4201 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 3
skydomeled
FSDL 22 | 33 | 44
focal point included hardware key
power off
power on
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
attention
luMinaire MuSt Be inStalled prior to ceilinG
skydome 2x2
skydome 3x3
skydome 4x4
provided By otherS
4 - 1/4-20 hanGer rodS
4 - c-channelS (drywall only)
8 - levellinG Support BracketS
12.00”
23.50”
8.625”
24.00”
22.50” cut-out
1.1875” Min 1.50” Max
24”
23.50”
23.50”
22.50”
ceilinG cutout
diaMeter
36"
35.50"
35.50"34.50"
ceilinG cutout
diaMeter
48"
47.50"
47.50"
46.50"
ceilinG cutout
diaMeter
2” Min 2.1875” Max
24.00"
35.50"
36.00"
34.5" cut-out
8.625"
4 - 1/4 20 hanGer rodS (By otherS)
4 - 1/4 20 hanGer rodS (By otherS)
4 - 1/4 20 hanGer rodS (By otherS)
8.625"
36.00"
47.50"
48.00"
46.5" cut-out
unit weiGht: 24 lBS.
unit weiGht: 44 lBS.
unit weiGht: 58 lBS.
1.1875" Min 1.50" Max
2" Min 2.1875" Max
2" Min
2.1875" Max
1.1875" Min
1.50" Max
"
IS0511 REV. C 2022 ©Focal Point, LLC 4201 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 3
Luminaires must be installed by a qualified electrician (check with local and national codes for proper installation).
To prevent electrical shock, disconnect electrical supply before installation or servicing.
GRID
Make electrical connectionS
65
12
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
x4
ceilinG cutout diaMeter - Grid & drywall
skydome 2x2 – 22.10" Min 22.50" Max
skydome 3x3 – 34.10" Min 34.50" Max
skydome 4x4 – 46.10" Min 46.50" Max
SECURE TO STRUCTURE ABOVE
(hanGer rodS By otherS)
7
REST CEILING TILE ON OUTER RING
4x8 LEVEL LUMINAIRE WITH
INCLUDED BRACKETS
3x8
Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls
and/or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC
is prohibited.
IS0511 REV. C 2022 ©Focal Point, LLC 4201 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 3
1 2
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
Make electrical connectionS
4
8
5
USE OUTER RING AS PLASTER FRAME
DRYWALL
1
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
23x4 SECURE TO STRUCTURE ABOVE
(hanGer rodS By otherS)
7x8 LEVEL LUMINAIRE WITH
INCLUDED BRACKETS
6x8
EMERGENCY
SEE BATTERY MANUFACTURER
INSTRUCTIONS
eMerGency MaxiMuM MountinG heiGht:
16.00'
DRIVER SERVICE
  • Page 1 1
  • Page 2 2
  • Page 3 3

Focal Point Skydome LED 2', 3', 4' - Recessed FSDL-22/33/44 Installation guide

Type
Installation guide

Ask a question and I''ll find the answer in the document