Focal Point Nivo Solid Diffuser FNVL-22-AC Installation guide

Type
Installation guide
IS0516 REV. E 2016 ©Focal Point, LLC 4201 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 1 of 3
Luminaires must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, diconnect electrical supply before installation or servicing.
nivoTM
FNVL 2x2
focal point
key
power off
power on
attention
AVOID ALL CONTACT WITH LED SURFACE, LEDs ARE EASILY DAMAGED!
2x4 3x4
1
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
suction cups
(FLUSH LENS ONLY)
MATCH PART NUMBERS FOUND ON
LENS AND HOUSING PACKAGING
LABELS FOR CORRECT PAIRING
solid diffuser hollow diffuser
9/16" GRID HOUSING (G2, G3, T2) 15/16" GRID HOUSING (G1, T1)
SHIELDING MOUNTING LENS RAIL POSITION SHIELDING MOUNTING LENS RAIL POSITION
AC1, AC3, AC5, AC7
AX3, AX5, AX7
G3, T2 1AC1, AC3, AC5, AC7
AX3, AX5, AX7
T1 5
G2 2G1 6
ACZ, AC2, AC4, AC6
AX2, AX4, AX6
G3, T2 3ACZ, AC2, AC4, AC6
AX2, AX4, AX6
T1 7
G2 4G1 8
lens MountinG Guide
LENS RAIL POSITION
LENS RAIL
IS0516 REV. E 2016 ©Focal Point, LLC 4201 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 2 of 3
Luminaires must be installed by a qualied electrician (check with local and national codes for proper installation).
To prevent electrical shock, diconnect electrical supply before installation or servicing.
31 2
drywall installation
see focal point fraMe kit
instruction sheet is160 Make electrical connections
driVer serVice
2
AVOID ALL CONTACT WITH LED SURFACE,
LEDs ARE EASILY DAMAGED!
DISCONNECT LENS LANYARD FROM HOUSING
1
USE INCLUDED SUCTION CUPS
FOR REMOVAL OF FLUSH LENS
1a
Make electrical connections
7
CONNECT LENS LANYARD TO HOUSING.
8
5x4 6x4
4
Contractor is responsible for adequately reinforcing walls and/or ceilings to support luminaire weight. Focal Point, LLC accepts no responsibility for inadequately reinforced walls and/
or ceilings. The information contained in this drawing is the sole property of Focal Point, LLC. Any reproduction in part or whole without the written permission of Focal Point, LLC
is prohibited. US Patents: D605,340; D605,341; D605,342; D608,490; D620, 190S. European Patents: 001596313-0001, 001596313-0002, 001596313-0003, 001596313-0004,
001596313-0005, 001596313-0006, 001596313-0007, 001596313-0008, 001596313-0009. Canadian Patents: 130763, 130764, 130765, 130766.
IS0516 REV. E 2016 ©Focal Point, LLC 4201 S. Pulaski Rd., Chicago, IL 60632 | www.focalpointlights.com 3 of 3
0-10V DIMMING & NON-DIMMING STANDARD WIRING
WHITE (NEUTRAL) BLACK (LINE)
GREEN
PURPLE (+)
GRAY (-)
PURPLE
GRAY
**OPTIONAL**
(individually capped at factory
for non-dimming applications)
(if shorted together, xture will
automaticaly dim to lowest setting)
0-10V DIMMER
*OUTPUT WIRE VARIATIONS:
RED (+), BLUE (-)
RED (+), BLACK (-)
BLACK (+), YELLOW (-)
(-)*
(+)*
LED
reference driVer Manufacturer’s spec sheets for driVer specific wirinG diaGraMs.
eMerGency luMinaires wired accordinG to Battery MANUFACTURER’s instructions.
EMERGENCY
SEE BATTERY MANUFACTURER
INSTRUCTIONS
eMerGency MaxiMuM MountinG heiGht:
18.00'