Product and Documentation Changes
SKOV A/S reserve the right to change this manual and the product described herein without further notice. In
case of doubt, please contact SKOV A/S.
Date of change appears from the back page.
In case of maloperation or improper use, ventilation systems can result in production loss or
cause loss of lives among animals.
SKOV A/S recommend that ventilation systems should be mounted, operated and serviced only
by trained staff and that a separate emergency opening unit and an alarm system be installed as
well as maintained and tested at regular intervals, according to SKOV’s terms and conditions of
sale and delivery.
Notice All rights reserved. No part of this manual may be reproduced in any manner whatsoever without
written permission from SKOV A/S.
SKOV A/S have made reasonable efforts to ensure the accuracy of the information contained in this
manual. Should any mistakes or imprecise information occur in spite of this, SKOV A/S would
appreciate being notified thereof.
Irrespective of the above, SKOV A/S shall not have any liability with respect to loss or damage
caused or alleged to be caused by reliance on any information contained herein.
Copyright 2014 by SKOV A/S.
Mounting Guide 3
Tunnel Door Light
1 SURVEY OF COMPONENTS ............................................................................. 4
2 PLATE TYPES .................................................................................................... 6
3 WINCH MOTOR MOUNTED ON THE WALL BEFORE THE DOOR ................ 7
3.1 DA 75 ......................................................................................................................... 7
3.2 DA 175 ....................................................................................................................... 9
4 WINCH MOTOR MOUNTED ON THE END WALL .......................................... 12
5 MOUNTING OF LOCK RAIL SUPPORT .......................................................... 14
6 MEASURING OF PROFILE LENGTH .............................................................. 15
7 ASSEMBLY DOOR PROFILE AND LOCKING RAIL SUPPORT ................... 16
8 ASSEMBLY BRACKET ON THE DOOR ......................................................... 19
9 MOUNTING OF KIT .......................................................................................... 20
9.1 Winch Motor Mounted on the Wall before the Door.............................................20
9.2 Winch Motor Mounted on the end Wall .................................................................21
10 MOUNTING OF MOTOR .................................................................................. 22
10.1 DA 75 ........................................................................................................................22
10.2 DA 175 ......................................................................................................................23
11 ADJUSTMENT .................................................................................................. 24
12 REINFORCEMENT OF THE DOOR (OPTIONAL) ........................................... 25
4 Mounting Guide
Tunnel Door Light
1 Survey of Components
Tunnel door light
1 pc.
432034
DA 75A-6 winch motor 230V
2 pcs.
415078
Pulley PV 24-108, bracket
2 pcs.
415063
Pulley 45 PV 24-108, reel GF30%
1 pc.
413033
Eye joiner M8 ss
6 pcs.
419312
Coach screw 8x70 A2 DIN571
8 pcs.
419336
Rawlplug 10 mm
1 pc.
413042
Wire lock 2-4 mm A2
2 pcs.
415033
Coil spring Ø30 x 300 mm stainless
1 pc.
419324
Coach eye screw 6x50 FZB
1 pc.
413044
Shackle M6 A2 short
1 pc.
415091
Pulley, bracket f. Covered creep area
1 pc.
419311
Coach screw 6x50 A2 DIN571
1 pc.
522942
Nylon string Ø3x3140mm
1 pc.
604015
MG Tunnel door light EN
1 pc.
432037
DA 75A-6 winch motor 24V
2 pcs.
415078
Pulley PV 24-108, bracket
2 pcs.
415063
Pulley 45 PV 24-108, reel GF30%
1 pc.
413033
Eye joiner M8 ss
6 pcs.
419312
Coach screw 8x70 A2 DIN571
8 pcs.
419336
Rawlplug 10 mm
1 pc.
413042
Wire lock 2-4 mm A2
2 pcs.
415033
Coil spring Ø30 x 300 mm stainless
1 pc.
419324
Coach eye screw 6x50 FZB
1 pc.
413044
Shackle M6 A2 short
1 pc.
415091
Pulley, bracket f. Covered creep area
1 pc.
419311
Coach screw 6x50 A2 DIN571
1 pc.
522942
Nylon string Ø3x3140mm
1 pc.
604015
MG Tunnel door light EN
Mounting Guide 5
Tunnel Door Light
3 pc.
415078
Pulley PV 24-108, bracket
2 pcs.
415063
Pulley 45 PV 24-108, reel GF30%
1 pcs.
413033
Eye joiner M8 ss
15pcs.
419312
Coach screw Ø8x70 stainless A2, DIN571
15pc.
419336
Wall dowel 10mm
2 pcs.
413042
Wire lock 2-4 mm A2
2 pcs.
415033
Coil spring Ø30 x 300 mm stainless
1 pc.
419324
Coach eye screw Ø6x50 galv.
1 pcs.
419335
Rawlplug 8 mm
1 pc.
413044
Shackle M6 A2 short
1 pc.
415092
Tunnel door light pulley 90º DA 175
1 pc.
413032
Lifting eye nut M10 Delta DIN582
1 pc.
357103
Hex screw fully thread M10x25 A2 DIN933
1 pc.
413022
Steel wire 5 mm 7x19 A4 10 meter
1 pc.
604015
MG Tunnel door light EN
1 pc.
504994
R&P light bracket for door, A2
2 pcs.
357078
Hex screw fully threaded M6x35 A2 DIN933
2 pcs.
352823
Lock nut M6 A2 DIN985
2 pcs.
419240
Washer ø6.4/ø30x1.5 A2
1 pc.
522034
Line guide incl. 5x48 screw
1 pc.
419335
Rawplug 8 mm
2 pcs.
419336
Rawplug 10 mm
1 pc.
522007
DA 1200 Clamp for pull rod
1 pc.
522931
Nylon string Ø3x1500mm
2 pcs.
419311
Coach screw 6x50 A2 DIN571
1 pc.
401349
All-purpose holder for pull rod
7 pcs.
521508
Tunnel door light lock rail 150 mm
14 pcs.
352794
Chipboard screw 5x30 pan pozi A2
14 pcs.
419335
Rawlplug 8 mm
1 pc.
522656
Multi-edge door profile 10-25 mm, 3 m
0.5 pcs.
530189
MS mount. glue 299 290 ml
0.045 pcs.
413109
Pull rod M8x5500mm galv
25 pcs.
352784
Chipboard screw 4x13 pan pozi A2
1 pc.
Joiner M8 ss
6 Mounting Guide
Tunnel Door Light
1 pc.
521507
Aluminum profile 5500 mm
6 pcs.
357078
Hex screw fully threaded M6x35 A2 DIN933
6 pcs.
352823
Locknut M6, A2
6 pcs.
352844
Washer Ø6.4/Ø18x1.6, A2
2 Plate Types
Suitable for plates of a thickness between 10 25 mm.
Mounting Guide 7
Tunnel Door Light
3 Winch Motor Mounted on the Wall before the Door
3.1 DA 75
419335 Rawlplug 8 mm
352794 A2 5x30 screw pan. Poz
521508 Tunnel door light lock rail 150 mm
+ 415078 Pulley PV 24-108, bracket
+ 415063 Pulley 45 PV 24-108, reel GF30%
+ 419312 Coach screw 8x70 A2 DIN571
+ 419336 Wall dowel 10 mm
Note: When
setting up the
number of cables
in the motor’s
pulley, please
make sure that
the correct
amount of
pulleys are set
according to the
angle set from
projecting.
2 Coil springs’s
preload distance
Min. 150 cm.
Max. 240 cm.
+ 413033 Eye joiner M8 ss
+ 413044 Shackle M6 A2 short
+ 413042 Wire lock 2-4 mm A2
432034 DA 75A-6
winch motor 230V
432037 DA 75A-6
winch motor 24V
8 Mounting Guide
Tunnel Door Light
401349 All-purpose holder for pull rod
522007 DA 1200 Clamp for pull rod
522034 Line guide incl. 5x48 screw
522656 Multi edge door profile 10-25mm, 3m
530189 MS mount. glue 292 290 ml
502098 Pullrod M8 x 3000 galv.
352784 Chipboard screw 4x13 pan pozi A2
504994 R&P light bracket for door, A2
357078 Hex screw fully threaded M6x35 A2 DIN933
352823 Lock nut M6 A2 DIN985
419240 Washer ø6.4/ø30x1,5 A2
530189 MS mount.
glue 292 290 ml
Mounting Guide 9
Tunnel Door Light
3.2 DA 175
432116 DA 175-300 actuator 230V
432112 DA 175-300 actuator 24V
415092 Tunnel door light pulley 90º DA 175
413032 Lifting eye nut M10 Delta DIN582
357103 Hex screw fully thread M10x25 A2 DIN933
413022 Steel wire 5 mm 7x19 A4 10 meter
415078 Pulley PV 24-108, bracket
413042 Wire lock 2-4 mm A2
413044 Shackle M6 A2 short
413042 Wire lock 2-4 mm A2
413033 Eye joiner M8 ss
415033 Coil spring Ø30 x 300 mm stainless
419324 Coach eye screw Ø6x50 galv.
419335 Rawlplug 8 mm
419335 Rawlplug 8 mm
352794 A2 5x30 screw pan. Poz
521508 Tunnel door light lock rail 150 mm
10 Mounting Guide
Tunnel Door Light
413032 Lifting eye nut M10 Delta DIN582
357103 Hex screw fully thread M10x25 A2 DIN933
413022 Steel wire 5 mm 7x19 A4 10 meter
415078 Pulley PV 24-108, bracket
413042 Wire lock 2-4 mm A2
415092 Tunnel door light pulley 90º DA 175
415033 Coil spring Ø30 x 300 mm
stainless
419324 Coach eye screw Ø6x50
galv.
419335 Rawlplug 8 mm
413044 Shackle M6 A2 short
413042 Wire lock 2-4 mm A2
413033 Eye joiner M8 ss
415078 Pulley PV 24-108, bracket
415063 Pulley 45 PV 24-108, reel GF30%
432116 DA 175-300 actuator 230V
432112 DA 175-300 actuator 24V
419335 Rawlplug 8 mm
352794 A2 5x30 screw pan. Poz
521508 Tunnel door light lock rail 150 mm
Mounting Guide 11
Tunnel Door Light
401349 All-purpose holder for pull rod
522007 DA 1200 Clamp for pull rod
522034 Line guide incl. 5x48 screw
522656 Multi edge door profile 10-25mm, 3m
530189 MS mount. glue 292 290 ml
502098 Pullrod M8 x 3000 galv.
352784 Chipboard screw 4x13 pan pozi A2
504994 R&P light bracket for door, A2
357078 Hex screw fully threaded M6x35 A2 DIN933
352823 Lock nut M6 A2 DIN985
419240 Washer ø6.4/ø30x1,5 A2
530189 MS mount.
glue 292 290 ml
12 Mounting Guide
Tunnel Door Light
4 Winch Motor Mounted on the end Wall
419335 Rawlplug 8 mm
352794 A2 5x30 screw pan. Poz
521508 Tunnel door light lock rail 150 mm
+ 415033 Coil spring Ø30 x 300 mm stainless
+ 419324 Coach eye screw 6x50 FZB
522007 DA1200 Clamp for pull rod
401349 All-purpose holder for pull rod
522034 Line guide incl. 5x48 screw
+ 413033 Eye joiner M8 ss
+ 413044 Shackle M6 A2 short
+ 413042 Wire lock 2-4 mm A2
+ 415078 Pulley PV 24-108, bracket
+ 415063 Pulley 45 PV 24-108, reel GF30%
+ 419312 Coach screw 8x70 A2 DIN571
+ 419336 Wall dowel 10 mm
432034 DA 75A-6
winch motor 230V
432037 DA 75A-6
winch motor 24V
Mounting Guide 13
Tunnel Door Light
401349 All-purpose holder for pull rod
522007 DA 1200 Clamp for pull rod
522034 Line guide incl. 5x48 screw
522007 DA 1200 Clamp for pull rod
+ 415091 Pulley, bracket f. covered creep area
432034 DA 75A-6
winch motor 230V
432037 DA 75A-6
winch motor 24V
504994 R&P light bracket for door, A2
357078 Hex screw fully threaded M6x35 A2 DIN933
352823 Lock nut M6 A2 DIN985
419240 Washer ø6.4/ø30x1,5 A2
530189 MS mount.
glue 292 290 ml
522656 Multi edge door profile 10-25mm, 3m
530189 MS mount. glue 292 290 ml
502098 Pullrod M8 x 3000 galv.
352784 Chipboard screw 4x13 pan pozi A2
14 Mounting Guide
Tunnel Door Light
5 Mounting of Lock Rail Support
Remark: The mounting area needs min. 60 mm of height.
Step : Mark the 56 mm. level from the bottom frame edge along the door frame, it is the lock rail’s bottom
position. The first and last lock rail positions at the same line of frame’s inside. The 475 mm. pitch is for each
lock rail (gap max 325 mm.) or adjustable at the actual place.
Step : Fasten by A2 5x30 screw pan. Poz.
Mounting Guide 15
Tunnel Door Light
6 Measuring of Profile Length
16 Mounting Guide
Tunnel Door Light
7 Assembly Door profile and Locking rail support
Slide the prepared profile for length of door opening into the groove of the mounted lock rail support.
Recheck the open-close rotation (60°) along these
profiles.
Correct assembly
Wrong assembly
Mounting Guide 17
Tunnel Door Light
18 Mounting Guide
Tunnel Door Light
Gluing
Mounting Guide 19
Tunnel Door Light
8 Assembly Bracket on the door
Mounting Brackets for Winch motor before Door
Mounting Brackets for Winch motor on the end wall
20 Mounting Guide
Tunnel Door Light
9 Mounting of Kit
9.1 Winch Motor Mounted on the Wall before the Door
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28

Skov Tunnel Door Light Mounting Guide

Type
Mounting Guide

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI