ACT ACTpro eLock User Instruction Manual

Type
User Instruction Manual
User Instruction Manual
Ref: 18-00087
THIS INSTALLATION GUIDE COVERS THE FOLLOWING PRODUCTS:
ACTpro eLock
ACTpro eLock 125Khz RFID
ACTpro eLock K
ACTpro eLock 125Khz RFID with external Key Override
ACTpro eLock K2
ACTpro eLock 125Khz RFID with internal & external Key Override
ACTpro eLock MF
ACTpro eLock MIFARE Classic/DESFire EV1
ACTpro eLock MFK
ACTpro eLock MIFARE Classic/DESFire EV1 with external Key Override
ACTpro eLock MFK2
ACTpro eLock MIFARE Classic/DESFire EV1 with internal & external Key Override
CARTON CONTENTS:
1. User Installation Manual (this document)
2. Front and Back escutcheons including 8mm spindle
3. Door drill template
4. 2 x Door handles and handle grub screws
5. 2 x 35mm and 2 x 45mm M5 Mounting screws
6. 2 x M3 6mm back cover fixing screws.
7. Screw cap cover
8. 2.5mm Hex Key
9. CR123A Battery
TOOLS REQUIRED:
1. Power drill
2. Drill bits 16mm and 8mm
3. Pozi screwdriver
4. Hex key 2.5mm (Supplied)
5. Thread locking adhesive
(ACT recommends Loctite 242).
The ACTpro eLock can be used on most mortise locks with 8mm spindle and is compatible with
door thicknesses from 36mm to 60mm.
The ACTpro eLock K and MFK versions support euro profile cylinder locks that are positioned 72mm
from the spindle centre; and has key override cut-out on the entry escutcheon only.
The ACTpro eLock K2 and MFK2 versions of the eLock support euro profile cylinder locks that are
positioned 72mm from the spindle centre; and has key override cut-out on the entry and exit escutcheon.
WIRELESS COMMUNICATIONS:
The ACTpro eLock and the eLock Hub communicate
wirelessly, operating at 868.8MHz. The communications
between the eLock and hub are secured using 128 bit
AES encryption.
The range of the wireless signal is dependent on the
characteristics of the building and it is recommended to
complete a site survey to determine the best location of
ACTpro eLock hubs.
OPERATION:
When a valid card is presented to the eLock, the LED will flash
green and the door will unlock.
If an invalid card is presented, the LED will flash red and the
door will remain locked.
Make sure cards and fobs are placed accurately over the card
read area on the ACTpro eLock. This is the area indicated by
the card logo on the front escutcheon.
DOOR MONITORING:
ACT supplies a door monitoring kit (order code ACTpro eLock
DM), which allows the door position to be monitored.
Wire the kit to the DOOR AJAR terminals on the ACTpro
eLock
BATTERY:
A low battery condition will be reported to the ACTenterprise
software. The ACTpro eLock will still continue to operate but
the battery should be replaced as soon as possible.
If the battery is completely flat, the ACTpro eLock can be
powered via the USB connector using a laptop or other USB
power source. Once the ACTpro eLock is powered over the
USB, presenting a valid card will unlock the door.
Depending on use, the battery can last up to 200,000
activations or 5 years.
CERTIFICATION:
ACT declares that this equipment fulfils the requirements
of EU EMC directive 2004/108/EC.
ENVIRONMENT:
Temperature: -10°C/+50°C
IP Rating: IP 55 - Not recommended for external use.
16mm
Installation Procedure Step by Step
Align the door drill template on the door. Use a spindle inserted through
the mortise lock to position the template correctly.
Drill the top hole using a 16mm bit. Drill the hole at
the bottom using an 8mm drill bit, drilling halfway from
either side of the door. (Top hole needs to be larger to
accommodate the eLock cable).
Mark the drill points on both sides of the door.
1
2
3
Fit the back escutcheon and spindle through the mortise lock. Thread the cable through
hole at the top of the back escutcheon. Push the spindle through the front escutcheon.
Thread the cable from the front escutcheon through
the top hole in the door. Do not force the cable or use
a sharp instrument to pass it through the door.
5
6
4
Ensure that the unit is aligned correctly. Screw
the units together tightly. Ensure the cable is
not trapped.
To default the ACTpro elock, insert battery and then hold down the tamper
switch and recessed button until the unit beeps and the LED flashes.
Insert the battery. The ACTpro eLock must only be
used with ACT supplied batteries. Note: Use of non-ACT
supplied batteries will invalidate the ACT warranty.
7
8
9
Plug in the ribbon cable connector. Note: Polarised guide
on the ribbon cable connector is on the right.
Apply thread locking adhesive to the handle
grub screws and fix handles securely.
Place the cover on unit. Screw the cover at the places indicated. The
bottom screw should be inserted first. Clip on the screw cap cover.
Peel off the protective cover.
10
11 12
Ireland Office
Unit C1, South City Business Park
Tallaght, Dublin 24
United Kingdom Office
4 Millennium House, Priestly Rd
Basingstoke, Hampshire, RG24 9NP
UK Lo-call 0845 300 5204
International +353 1 466 2570
www.accesscontroltechnology.com