Master VV1238 Operating instructions

Type
Operating instructions

This manual is also suitable for

Master VV1238: Your gateway to a smarter and more connected home. With cutting-edge AI technology, this device learns your preferences and routines, allowing for personalized automation and control of your smart devices. From adjusting lighting and temperature to managing entertainment and security systems, the Master VV1238 puts the power of a smart home at your fingertips.

Master VV1238: Your gateway to a smarter and more connected home. With cutting-edge AI technology, this device learns your preferences and routines, allowing for personalized automation and control of your smart devices. From adjusting lighting and temperature to managing entertainment and security systems, the Master VV1238 puts the power of a smart home at your fingertips.

SPEC DATA SHEET
1 | Page MASTER PAINT & CHEMICAL CORP. CARR#127 KM 12.7 BO. MAGAS GUAYANILLA PR 00656
TEL: 787-835-4000 / FAX: 787-835-2965 / E-FAX: 787-966-7180
Rev. 0
Supersedes September, 2016
Masterflex Ultimate Armour 200®
Innovative Cross-Linking Technology
Over 200 hours of water ponding resistance
SECTION 1 - PRODUCT DESCRIPTION
SECTION 2 - TYPICAL USE
SECTION 3 - PRODUCT ADVANTAGE
SECTION 4 - COLO
R
SECTION 5 - GLOSS
Masterflex Ultimate Armour 200® is an innovative ultra white acrylic elastomeric roof sealer, based on an exclusive cross-linking technology
that resists critical water ponding conditions. It offers outstanding long-term durability and toughness to prevent leakage and fix roofs with
already leaking problems, caused by capillarity, cracks or joints. Highly resistant to damage caused by UV rays, dirt, water or other common
weather elements. It also has excellent adhesion to concrete, polyurethane foam, galvanized metal and aluminum. It can significantly reduce the
interior temperature up to 20 degrees, resulting in energy savings and cooling costs.
Masterflex Ultimate Armour 200® is used for waterproofing and protection of concrete, polyurethane foam, galvanized metal and
aluminum. With additional advantages it is highly resistant to water ponding (200 hours +). However, for a more durable and efficient
protection, all water ponding areas should be fixed with Masterflex Leveling Repair®. If water ponding areas are not fixed, they must be
repaired by the installation of an efficient drain system and annual maintenance. This maintenance should be done by applying two coats of
MASTERFLEX ULTIMATE ARMOUR 200®.
2 in 1: Primer & Sealer
Low water absorption and permeability
Roof Defense Technology: Polyfiber plus® Technology made out
of resins, fibers and additives.
Certified Roof Formula that reduces mold and mildew on the dry
sealer film, maintaining the roof white to save energy.
Brilliant Ultra White finished
Reflective flat finish
SECTION 6 - COMPOSITION
Cross linking acrylic polymer, titanium dioxide and reflective and inert pigments. Free of lead, chromates and mercury.
SECTION 7 – PHYSICAL AND CHEMICAL PROPERTIES
Viscosity: 115 +/- 5 KU (Stormer) Flash Point: None Weight per gallon: 11.30 +/- 0.15 lb/gal
Solids per Volume: 50 +/-1 % Solids per weight: 65+/-1 %
Excellent dirt pickup resistance
Ultra white. Reflects 98% of solar rays and reduces interior
temperature up to 20°.
Fast dry
LOW VOC: 50g/L volatile organic compounds
Remains flexible in any weather conditions
Excellent adhesion to concrete, polyurethane foam, galvanized
metal and aluminum
Coverage: 400 ft² per pail
SPEC DATA SHEET
2 | Page MASTER PAINT & CHEMICAL CORP. CARR#127 KM 12.7 BO. MAGAS GUAYANILLA PR 00656
TEL: 787-835-4000 / FAX: 787-835-2965 / E-FAX: 787-966-7180
Rev. 0
Supersedes September, 2016
SECTION 9 - APPLICATION
SECTION 10 – APPLICATION TOOLS
SECTION 11 – CAUTION
Before attempting to apply, mix the product well in a circular upward-downward motion, preferably with a mechanical agitator. Apply it
using a good quality long hair roller or an airless spray machine. In small areas and corners, it can be applied with a brush. For best results:
Apply in accordance with Guide Specifications, available at Master Paints and Chemical Corp. and at your retail store.
Airless Machine Application: Mix this product with a mechanical mixer. Remove the filter of the suction pump and the machine filter.
Program the machine to apply this product with 1,400 to 1,750 psi and use a fan width of 6 in order to control the overspray of material. Use a
pistol tip for a .29” to a .41” spray. Make sure that rain is not forecasted for that day. If the roof is too hot, spray it lightly with water so that
the sealer does not dry too quickly.
Recommended Film Thickness: 20 mils dry / 40 mils wet
Coverage: Two coats must be applied in order to get the recommended 20 mils dry film thickness (MDFT). Apply each coat in different
directions and wait 12 hours between each coat. Select a clear and sunny day for application.
Coverage 1 coat ft² (m²) per pail
Concrete Surfaces
400 ft² (37.5 m²) per pail @ 10 MDFT
Metal Surfaces
800 ft² (37.5 m²) per pail @ 5 MDFT
Foam Surfaces
400 ft² (37.5 m²) per pail @ 10 MDFT
Thinning: This product is ready to use and should be applied full strength as received in the can. Any thinning of the product will reduce the
percentage of solids, which will adversely affect the dry film thickness and the durability of the applied sealer.
Clean UP: Clean all application equipment with soap and water.
It can be applied using a brush, roller, or atomizer.
HARMFUL IF SWALLOWED. MAY CAUSE EYE, NOSE AND THROAT IRRITATION. AVOID CONTACT WITH SKIN AND EYES
AND AVOID BREATHING OF VAPORS AND SPRAY MIST. USE ONLY WITH ADEQUATE VENTILATION. When applying spray,
use respiratory protection (NIOSH/MSHA TC23C or equivalent), eye protection and protective clothing. Before use, ask and read the Safety
Data Sheet (SDS) of the product, available at Master Paint & Chemical Corp. Close container after each use. KEEP OUT OF REACH OF
CHILDREN.
SECTION 8 – SURFACE PREPA
R
ATION
Roof surface should be cleaned by eliminating all residues of dust, sand, cement, mold, mildew, and strange particles. Use a water pressure
machine. Roof’s drain system should be repaired if it does not allow water to exit. For concrete roofs, repair holes that are greater than ½ inch
or any water ponding area by using Masterflex Leveling Repair®.
Crack Repair: All joints and cracks have to be sealed. Apply Masterflex Elastomeric Crack Filler® with a spatula and the Masterflex
Fiberglass Patch Weave® on top of cracks, joints, and around all objects that are anchored to the roof, by covering at least two inches more on
each side. Let it dry for 24 hours before applying the roof sealer.
WARNING! If you scrape, sand, or remove old paint, you may release lead dust or fumes. LEAD IS TOXIC. EXPOSURE TO LEAD
DUST OR FUMES CAN CAUSE SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT
WOMEN SHOULD ALSO AVOID EXPOSURE. Wear a properly fitted NIOSH approved respirator and prevent skin contact to control
lead exposure. Clean up carefully with a HEPA vacuum and a wet mop. Before you start, find out how to protect yourself and your family by
contacting the USEPA National lead Information Hotline at 1-800-424 LEAD or log on to www.epa.gov/lead.
SPEC DATA SHEET
3 | Page MASTER PAINT & CHEMICAL CORP. CARR#127 KM 12.7 BO. MAGAS GUAYANILLA PR 00656
TEL: 787-835-4000 / FAX: 787-835-2965 / E-FAX: 787-966-7180
Rev. 0
Supersedes September, 2016
The information and recommendations set forth in this Product Data Sheet are based upon test conducted by Master Paints and
Chemical Corp. Since application variables are a major factor in product performance, this information should serve only as a
general guide. Improvements in coating technology may cause future technical data to vary from what is in this bulletin. Consult
your Master Paints and Chemical Corp. representative or call 787 835 4000 to obtain the most recent Product Data Sheet
SECTION 12 – FIRST AID
SECTION 14 – PACKAGING
1 gallon and 5 gallon pails
In case of skin contact, remove product from skin with soap and water. When eye contact with products occurs, rinse affected area with large
amounts of water at least 15 minutes and get immediate medical attention. If swallowed, medical attention is needed immediately. Do not
apply late in the day or when rain or dew is likely. Storage the air tight sealed product in a dry and well ventilated environment. For proper
disposal of excess material, please contact your local city waste management agency. PLEASE DO NOT DISPOSE OF REMNANTS IN
SEWERS.
SECTION 13 – LIMITED WARRANTY
Master Paints & Corp. warranties the original buyer of this product ONLY WHEN APPLIED ACCORDING TO SPECIFIED
INSTRUCTIONS IN THE PRODUCT LABEL (such as surface preparation, crack repair, recommended square feet coverage, and use of
patch weave to reinforce cracks and joints), that MASTERFLEX ULTIMATE ARMOUR 200®will seal against leaks in the roof area where
it is applied for FIVE (5) YEARS after date of purchase. This warranty is only valid when the total roof area is sealed with MASTERFLEX
ULTIMATE ARMOUR 200® including drains, inverted beams, parapets, eaves, and any other adjacent surface that can affect the product
performance. This warranty does not apply to adjacent roof structures that for some reason are joined to it. This product warranty is limited
exclusively to the surface where it was applied. Buyer remedies under this warranty are limited to the replacement of the product or a refund of
the product’s cost when the product does not meet our specifications and quality standards. This warranty does not cover application costs or
other related costs. This warranty will be the only and exclusive remedy available for the buyer and it is non-transferable. MASTER PAINTS
& CHEMICAL, CORP. DOES NOT WARRANTY AND WILL NOT BE LIABLE FOR DAMAGE PRODUCED FOR THE WRONGFUL
USE OF THIS PRODUCT, OR FROM NOT FOLLOWING SPECIFIED INSTRUCTIONS FOR THIS PRODUCT’S USE AND
APPLICATION BY A CONTRACTOR OR THIRD PARTY WITHOUT THE PROPER LICENSE FOR SEALING AND ROOF REPAIR IN
PUERTO RICO. This warranty does not cover problems caused by natural events such as hurricanes, storms, earthquakes, fire, floods, wind,
lightning, and structural defects or causes beyond the control of Master Paints & Chemical, Corp., including the abuse or bad use of the
product or negligence in its use or application. Warranty does not apply when the original application is altered, adequate maintenance is not
provided according to the specified product label instructions, or a structure or construction is added to it. Any claim under this warranty
should be done by written letter addressed to Master Paints & Chemical Corp. on or before 15 days after finding the alleged leak or defect. All
claims received will be verified during a reasonable time. To make this warranty valid, buyer should send by mail before 30 days after
purchasing this product, proof of purchase with his/her name and address to: Master Paints & Chemical, Corp., ATT: Customer Service
Department, P.O. 560248, Guayanilla, PR 00656-0248. This warranty does not apply to commercial works. For such matters, please
communicate with Master Paints & Chemical, Corp. at (787) 835-4000, 835-4001, 835-1295 or 787-740-5254.
SPEC DATA SHEET
4 | Page MASTER PAINT & CHEMICAL CORP. CARR#127 KM 12.7 BO. MAGAS GUAYANILLA PR 00656
TEL: 787-835-4000 / FAX: 787-835-2965 / E-FAX: 787-966-7180
Rev. 0
Supersedes September, 2016
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4

Master VV1238 Operating instructions

Type
Operating instructions
This manual is also suitable for

Master VV1238: Your gateway to a smarter and more connected home. With cutting-edge AI technology, this device learns your preferences and routines, allowing for personalized automation and control of your smart devices. From adjusting lighting and temperature to managing entertainment and security systems, the Master VV1238 puts the power of a smart home at your fingertips.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI