Master VA0455 Operating instructions

Type
Operating instructions

This manual is also suitable for

Master VA0455 is a versatile and user-friendly digital multimeter designed to provide accurate and reliable measurements for various electrical tasks. It features a large, easy-to-read LCD display, automatic ranging, and a variety of measurement functions including AC/DC voltage, AC/DC current, resistance, capacitance, frequency, and duty cycle. The multimeter also comes with a built-in flashlight for working in low-light conditions and a continuity beeper for quick troubleshooting.

Master VA0455 is a versatile and user-friendly digital multimeter designed to provide accurate and reliable measurements for various electrical tasks. It features a large, easy-to-read LCD display, automatic ranging, and a variety of measurement functions including AC/DC voltage, AC/DC current, resistance, capacitance, frequency, and duty cycle. The multimeter also comes with a built-in flashlight for working in low-light conditions and a continuity beeper for quick troubleshooting.

MASTER PAINTS & CHEMICAL CORP. CARR # 127 KM. 12.7 BO. MAGAS. GUAYANILLA PR 00656
Tel: 787-835-4000 / Fax: 787-835-2965 / e-fax: 787-966-7180
Rev. May-05, 2014
Page 1 of 2 Supersedes May, 2012
Masterflex®
The Thickest Award Winning Roof Sealer
Professional Roof Sealer * 100% Acrylic Elastomeric
SECTION 1 - PRODUCT DESCRIPTION
SECTION 2 - TYPICAL USE
SECTION 3 - PRODUCT ADVANTAGE
SECTION 4 - COLOR
SECTION 5 - GLOSS
SPEC DATA SHEET
Masterflex is an 100% acrylic elastomeric sealer of one component, designed for fixing leaks in roofs and walls, caused by capillarity,
cracks or joints when adding new constructions to existing ones. Masterflex is highly flexible. It is a product that is internally plasticized
in order to retain its mechanical properties and its adhesion, even after years of exposure to the sun and the rain. Masterflex leaves a
brilliant white finish, reducing surface heat absorption up to 15°F.
Masterflex® is used for waterproofing and protecting asphalt, concrete, wood, roof tiles, galvanized metal (exposed for some time), built
up roofs, and roof asphalt shingles.
Maximum adhesion on concrete roofs, wood, asphalt
and metal
Higher water pounding resistance without membrane
deterioration eliminating all types of filtration
Super fast dry
Roof Sealer dry film is Mold & Mildew Resistant
Ultra white finish which reduces interior temperature
Dry Film Yields up to 80 sq. ft. per gallon
100% Elastomeric Acrylic
Brilliant Ultra White finished
Flat
SECTION 6 - COMPOSITION
100% Elastomeric Acrylic Resins, free of lead and, chromates and mercury.
SECTION 7 PHYSICAL AND CHEMICAL PROPERTIES
Viscosity: 110 115KU (Stormer) Flash Point: None
Weight per gallon: 11.2 +/- 0.15 Lbs Solids per Volume: 50%
Solids by weight: 60% VOC Content max (grams/liter) 43
2 in 1 Primer and Sealer
Fiber Reinforced for More Protection, Strength &
Durability
Thicker Coating Against Filtrations
Energy Star Partner
Low VOC
Saves Energy - Saves Money
Complies with ASTM D6083
MASTER PAINTS & CHEMICAL CORP. CARR # 127 KM. 12.7 BO. MAGAS. GUAYANILLA PR 00656
Tel: 787-835-4000 / Fax: 787-835-2965 / e-fax: 787-966-7180
Rev. May-05, 2014
Page 2 of 2 Supersedes May, 2012
SECTION 9 - APPLICATION
SECTION 10 APPLICATION TOOLS
SECTION 11 CAUTION
SECTION 12 FIRST AID
SECTION 13 PACKAGING
1 gallon and 5 gallon pails
It can be applied using a brush, roller, or atomizer.
Recommended Film Thickness: 20 mils dry / 40 mils wet
Coverage: (One Coat)
Concrete surface: 80 square feet per gallon @ 10 MDFT/ 400 square feet per pail @ 10 MDTF
Metal Surface: 160 square feet per gallon @ 5 MDTF/ 800 square feet per pail @ 5 MDTF
Wood Surface: 80 square feet per gallon @ 10 MDTF/ 400 square feet per pail @ 10 MDTF
Built- up roofs: 40 square feet per gallon @ 20 MDTF/ 200 square feet per pail @ 20 MDTF
This sealer contains acrylic resins. It can cause eye, skin, or throat irritation. Do not take internally. Close container after each use. When
spray applying, use respiratory protection (NIOSH/MSHA TC23C or equivalent), eye protection and protective clothing. For more information
read the MSDS, available at Master paints and Chemical Corp. KEEP OUT OF REACH OF CHILDREN
In case of skin contact, flush from skin with water and then wash thoroughly with soap and water. In case of eye contact, flush immediately
with large amounts of water for at least 15 minutes and get emergency medical attention. If swallowed, get medical attention immediately. For
more information, request Material Safety Data Sheet of the product available at Master Paints & Chemical Corp.
SECTION 8 SURFACE PREPARATION
The roof or surface should be free from dust, sand, cement, fungus and strange objects. A pressure washer machine is recommended. Before
applying Masterflex®, improve water drainage where it is necessary and repair areas where standing water last one day or more. Less severe
pounding areas must be re-coated annually with Masterflex®.
Masterflex® will resist standing water (for 100 hours). However, we recommend repairing and correcting excessive pounding water and
improperly drained areas for a better and efficient sealing by using the Leveling Repair from Master. Roof with excessive pounding water and
improperly drained areas require annual maintenance, applying two (2) coats of Masterflex®.
How to Correct Cracks: Make sure all joints and cracks are sealed with a putty knife by applying Master Elastomeric Crack Filler and the
Master Fiberglass Patching Weave over cracks, seams, flashing and around any standing object, about two inches to both sides and let dry for
24 hours before applying Masterflex®. Apply Master Elastometric Crack Filter with a putty knife. While product is wet, roll out polyester
weave. While product is still wet, apply another coat of Master Elastomeric Crack Filler over the polyester weave.
WARNING! If you scrape, sand, or remove old paint, you may release lead dust or fumes. LEAD IS TOXIC. EXPOSURE TO LEAD
DUST OR FUMES CAN CAUSE SERIOUS ILLNESS, SUCH AS BRAIN DAMAGE, ESPECIALLY IN CHILDREN. PREGNANT
WOMEN SHOULD ALSO AVOID EXPOSURE. Wear a properly fitted NIOSH approved respirator and prevent skin contact to control
lead exposure. Clean up carefully with a HEPA vacuum and a wet mop. Before you star, find out how to protect yourself and your family by
contacting the USEPA National lead Information Hotline at 1-800-424 LEAD or log on to www.epa.gov/lead.
Two coats must be applied in order to get the recommended dry film thickness (MDTF).
Thinning: Not recommended.
Dry time: 1-2 hours to touch
12 hours to recoat
The information and recommendations set forth in this Product Data Sheet are based upon test conducted by Master Paints and Chemical Corp.
Since application variables are a major factor in product performance, this information should serve only as a general guide. Improvements in
coating technology may cause future technical data to vary from what is in this bulletin. Consult your Master Paints and Chemical Corp.
representative or call 787 835 4000 to obtain the most recent Product Data Sheet.
  • Page 1 1
  • Page 2 2

Master VA0455 Operating instructions

Type
Operating instructions
This manual is also suitable for

Master VA0455 is a versatile and user-friendly digital multimeter designed to provide accurate and reliable measurements for various electrical tasks. It features a large, easy-to-read LCD display, automatic ranging, and a variety of measurement functions including AC/DC voltage, AC/DC current, resistance, capacitance, frequency, and duty cycle. The multimeter also comes with a built-in flashlight for working in low-light conditions and a continuity beeper for quick troubleshooting.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI