ABB 2117 U-500 Operating instructions

Type
Operating instructions

This manual is also suitable for

1473-1-7978 14.06.2012
DALI potentiometer for broadcast operation
Pos: 2 /#Neustruktur#/ Modul-Struktur /Online-Dokumentati on/Titelblätter/ Dimmer/Titelbla tt - 2117 U @ 23\mod_13361231 92553_15.docx @ 208974 @ @ 1
DALI potentiometer for
broadcast operation
Insert 2117 U-500
Insert 2117/11 U-500
=== Ende der Liste für Textmarke Co ver ===
DALI potentiometer for broadcast
operation
| 1473-1-7978 — 2 —
Pos: 4 /#Neustruktur#/ Modul-Struktur /Online-Dokumentati on/Inhaltsverzei chnis (--> Für alle Dokumente <--)/Inhaltsverzeichnis @ 19\mod_132064904 4386_15.docx @ 109653 @ @ 1
1 Safety ....................................................................................................................................................................... 3
2 Intended use ............................................................................................................................................................ 3
3 Environment ............................................................................................................................................................. 3
4 Operation ................................................................................................................................................................. 4
4.1 Dimming speed ....................................................................................................................................... 4
4.2 Adjusting the basic brightness ................................................................................................................ 4
4.3 Deleting the basic brightness .................................................................................................................. 5
4.4 Activation with memory function .............................................................................................................. 5
4.5 Changing the switch-on brightness ......................................................................................................... 5
4.6 Deleting the switch-on brightness ........................................................................................................... 6
4.7 Adjusting the colour of the light for orientation ........................................................................................ 6
4.8 Changing the power-on level (optional setting): ...................................................................................... 7
4.9 Operation at several control points ......................................................................................................... 7
5 Technical data.......................................................................................................................................................... 8
6 Setup and function ................................................................................................................................................... 9
6.1 Features of function and equipment ........................................................................................................ 9
6.2 Possible combinations ............................................................................................................................ 9
7 Installation and electrical connection ..................................................................................................................... 10
7.1 Requirements for the electrician ........................................................................................................... 10
7.2 Mounting ............................................................................................................................................... 11
7.3 Inserting optical fibres ........................................................................................................................... 11
7.4 Electrical connection ............................................................................................................................. 12
=== Ende der Liste für Textmarke TOC ===
DALI potentiometer for broadcast
operation
Safety
| 1473-1-7978 — 3 —
Pos: 6 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Sicherheit @ 18\mod_130261 2791790_15.doc x @ 103357 @ 1 @ 1
1 Safety
Pos: 7 /#Neustruktur#/ Online-Dokument ation/Sicherhei tshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ @ 1
Warnin
g
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
Work on the 230V supply system may only be performed by authorised electricians!
Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 8 /#Neustruktur#/ Online-Dokument ation/Sicherhei tshinweise und Hinweise (--> Für alle Dokumente <--)/Allgemeine Hinweise/Hinweis - Basisorientiert-Kein SELV -- 2117 @ 21\mod_1331202989918_15.d ocx @ 201957 @ @ 1
Hint
DALI potentiometer 2117 U-500 and 2117/11 U-500 have basic insulation (no SELV).
Pos: 9 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bestimmungsgemäßer Gebrauch @ 18\mod_130276332 1316_15.docx @ 103483 @ 1 @ 1
2 Intended use
Pos: 10 /#Neustruktur #/Modul-Struktur /Online-Dokumenta tion/Bestimmungsge mäßer Gebrauch/Dimmer /Bestimmungsgemae sser Gebrauch - 2117 @ 21\mod_13312 02666263_15.doc x @ 201942 @ @ 1
DALI potentiometer 2117 U-500 and 2117/11 U-500 are used for light control in connection with DALI operating
devices according to IEC 62386, e.g., DALI electronic ballast units. No other DALI controllers must be combined
with DALI potentiometer 2117 U-500 and 2117/11 U-500.
Pos: 11.1 /#Neustrukt ur#/Modul-Strukt ur/Online-Dokumen tation/Überschr iften (--> Für alle Dokume nte <--)/1. Ebene/ U - Z/Umwelt @ 18\mod_1302614158 967_15.docx @ 103383 @ 1 @ 1
3 Environment
Pos: 11.2 /#Neustrukt ur#/Online-Dokumen tation/Sicher heitshinweise und Hin weise (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - Hinweis Elektrogeräte @ 18\mod_1302763973434_15.docx @ 103500 @ @ 1
Consider the protection of the environment!
Used electric and electronic devices must not be disposed of with domestic waste.
The device contains valuable raw materials which can be recycled. Therefore, dispose of the
device at the appropriate collecting depot.
Pos: 11.3 /#Neustrukt ur#/Online-Dokumen tation/Sicher heitshinweise und Hin weise (--> Für alle Dokumente <--)/Hinweise/Hinweis - Umwelt - Entsorgung Elektrogeräte @ 20\mod_13257606 95972_15.docx @ 136583 @ @ 1
All packaging materials and devices bear the markings and test seals for proper disposal. Always dispose of the
packaging material and electric devices and their components via the authorized collecting depots and disposal
companies.
The products meet the legal requirements, in particular the laws governing electronic and electrical devices and
the REACH ordinance.
(EU Directive 2002/96/EC WEEE and 2002/95/EC RoHS)
(EU REACH ordinance and law for the implementation of the ordinance (EC) No.1907/2006)
Pos: 12 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268 898668093_0.docx @ 52149 @ @ 1
DALI potentiometer for broadcast
operation
Operation
| 1473-1-7978 — 4 —
Pos: 13 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Bedienung @ 11\mod_1279185541 649_15.docx @ 83043 @ 1 @ 1
4 Operation
Pos: 14 /#Neustruktur #/Modul-Struktur /Online-Dokumenta tion/Bedienung/Di mmer/Bedienung - 2117 @ 21\ mod_1331210626890_15. docx @ 202059 @ 222222222 @ 1
4.1 Dimming speed
Fig. 1:
Slow rotation of the control element:
- Fine setting with up to 254 brightness levels.
Fig. 2:
Fast rotation of the control element:
- Large brightness changes in order to reach the desired setting quickly.
4.2 Adjusting the basic brightness
Fig. 3:
Turn the control element slowly to adjust the basic brightness.
1. Switch the lighting on.
2. Adjust the brightness.
3. Press the control element for 10 seconds.
- The load flashes once after the setting has been made.
ON
10 Sec.
DALI potentiometer for broadcast
operation
Operation
| 1473-1-7978 — 5 —
4.3 Deleting the basic brightness
Fig. 4:
Turn the control element slowly to delete the basic brightness.
1. Switch the lighting off.
2. Press the control element for 10 seconds.
- The load flashes once after the setting has been made.
4.4 Activation with memory function
At the factory, the DALI potentiometers are set to always switch on the illumination using the last brightness set
(memory function). The manual adjustment of the switch-on brightness overwrites this function.
4.5 Changing the switch-on brightness
Fig. 5:
To adjust a fixed switch-on brightness carry out the following steps:
1. Switch the lighting on.
2. Adjust the brightness.
3. Double click fast on the control element.
- The load flashes twice after the setting has been made.
The defined brightness overwrites the memory function (activation with the last brightness before deactivation).
Hint
If the illumination switches off after the double-click, the interval between the first and second button
operation was too long.
10 Sec.
OFF
ON
2x Click
DALI potentiometer for broadcast
operation
Operation
| 1473-1-7978 — 6 —
4.6 Deleting the switch-on brightness
Fig. 6:
To delete a fixed switch-on brightness carry out the following steps:
1. Switch the lighting on.
2. Double click fast on the control element.
- The load flashes twice after the setting has been made.
After the deletion of the switch-on brightness, the memory function continues to work (activation with the last
brightness before deactivation).
4.7 Adjusting the colour of the light for orientation
Fig. 7:
To change the colour of the light for orientation carry out the following steps:
1. Switch the lighting (load) off.
2. Press the control element, keep it pressed and turn it quickly back and forth three times.
3. Release the control element.
- The light for orientation flashes 3 times.
4. Select the colour of the LED by turning the control element.
5. Confirm the selection of the colour with a brief press of the control element.
- When the setting has been made the orientation light flashes 3 times.
OFF
2x Click
OFF
Press
Click
DALI potentiometer for broadcast
operation
Operation
| 1473-1-7978 — 7 —
4.8 Changing the power-on level (optional setting):
Fig. 8:
Changing the power-on level (switch-on brightness after mains power failure) effects a uniform brightness or
deactivation of all connected operating devices with the last set brightness value before the power failure.
To change the power-on level carry out the following steps:
1. Switch the lighting (load) off.
2. Press the control element, keep it pressed and turn it quickly back and forth three times.
3. Release the control element.
- The light for orientation flashes 3 times.
4. Press the control element for 10 seconds.
- After the setting has been made the lighting (load) flashes once and the light for orientation 3 times.
When the mains voltage returns, the DALI control unit now switches on at the last brightness set.
4.9 Operation at several control points
The DALI control units can be operated from several control points. In the process, the brightness of the last
operated potentiometer is always assumed first. This also applies to all other settings, such as basic brightness
and memory function.
The colour of the light for orientation must be selected individual for each DALI potentiometer in a system.
Pos: 15 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268 898668093_0.docx @ 52149 @ @ 1
OFF
Press
10 Sek.
DALI potentiometer for broadcast
operation
Technical data
| 1473-1-7978 — 8 —
Pos: 16 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/S - T/Technische Daten @ 11\ mod_1279185386320_15.d ocx @ 83019 @ 1 @ 1
5 Technical data
Pos: 17 /#Neustruktur #/Modul-Struktur /Online-Dokumenta tion/Technische Dat en/Dimmer/Technisc he Daten - 2117 @ 21\mod_133120 3423023_15.doc x @ 201983 @ @ 1
2117 U-500
Nominal voltage:
(via an external DALI power supply)
9.5 – 22.5 V
"
Power consumption:
(dependent on the colour of the orientation illumination)
7 – 15 mA
Protective circuit electronic
Maximum connectable DALI operating devices:
(dependent on an external power supply)
64
Operating temperature: 0° C – +35° C
Protective class: IP20
Maximum cable length in the system: 300 m
Number of colours of the light for orientation: 18 + Off
2117/11 U-500
Nominal voltage: 230 V~ ±10%, 50 / 60 Hz
Power consumption: 7 – 15 mA
Open circuit voltage, output voltage: 15.5 V
"
Maximum drawn current: 75 mA
Protective circuit electronic
Maximum connectable DALI operating devices: 37
Operating temperature: 0° C – +35° C
Protective class: IP20
Maximum cable length in the system: 300 m
Number of colours of the light for orientation: 18 + Off
Pos: 18 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268 898668093_0.docx @ 52149 @ @ 1
DALI potentiometer for broadcast
operation
Setup and function
| 1473-1-7978 — 9 —
Pos: 19 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/A - F/Aufbau und Funktion @ 11\ mod_1279185435352_15. docx @ 83027 @ 1 @ 1
6 Setup and function
Pos: 20 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/2. Ebene/A - F/Funktions- und Ausst attungsmerkmale @ 23\mod_1 336557630140_15.d ocx @ 209136 @ 2 @ 1
6.1 Features of function and equipment
Pos: 21 /#Neustruktur #/Online-Dokumen tation/Aufbau und Funkti on/Dimmer/Funkti onen - 2117 @ 21\mod_13312051 01538_15.docx @ 201999 @ @ 1
DALI potentiometer 2117 U-500 and 2117/11 U-500 are used to control the brightness of connected DALI
operating devices (e.g., DALI electronic ballast units, DALI LED modules, etc).
They operate in broadcast mode (uniform actuation of all DALI control units in the system).
For DALI potentiometer 2117 U-500 an additional external DALI power supply is required. Device 2117/11 U-500
has its own power supply.
Pos: 22 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/2. Ebene/G - L/Kombinationsmögli chkeiten @ 19\mod_1320312 769153_15.doc x @ 109520 @ 2 @ 1
6.2 Possible combinations
Pos: 23 /#Neustruktur #/Modul-Struktur /Online-Dokumenta tion/Kombinations möglichkeiten/Di mmer/Kombinations möglichkeiten - 2117 @ 23\ mod_1336994253800_15. docx @ 209443 @ @ 1
2117 U
2117/11 U
2115-21x
X X
6540-xxx
X X
6540-8xx-102
X X
Pos: 24 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.docx @ 52149 @ @ 1
DALI potentiometer for broadcast
operation
Installation and electrical
connection
| 1473-1-7978 — 10 —
Pos: 25 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/1. Ebene/M - O/Montage und elektrisc her Anschluss @ 23\mod_1336477 157864_15.doc x @ 209033 @ 1 @ 1
7 Installation and electrical connection
Pos: 26 /#Neustruktur #/Online-Dokumen tation/Sicherhei tshinweise und Hinweis e (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Niederspannungs- und 230 V-Leitungen @ 23\mod_133 6558868201_15.doc x @ 209164 @ @ 1
Warnin
g
Electric voltage!
Risk of death due to electrical voltage of 230 V during short-circuit in the low-voltage line.
- Low-voltage and 230 V lines must not be installed together in a flush-mounted socket!
Pos: 27 /#Neustruktur #/Online-Dokumen tation/Sicherhei tshinweise und Hinweis e (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Vorgeschaltete Sicherung abschalten @ 20\mod_132644171146 7_15.docx @ 137043 @ @ 1
Warnin
g
Electric voltage!
The upstream fuse must be disconnected when working on the lighting system.
Pos: 28 /#Neustruktur #/Online-Dokumen tation/Sicherhei tshinweise und Hinweis e (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Fachkenntnisse @ 23\mod_1336559183027_15.docx @ 209179 @ 2 @ 1
7.1 Requirements for the electrician
Warnin
g
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
Incorrect installation endangers your life and that of the user of the electrical system.
Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth and short-circuit;
5. Cover or barricade adjacent live parts.
Use suitable personal protective clothing.
Use only suitable tools and measuring devices.
Check the supply network type (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
Pos: 29 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268 898668093_0.docx @ 52149 @ @ 1
DALI potentiometer for broadcast
operation
Installation and electrical
connection
| 1473-1-7978 — 11 —
Pos: 30 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960 458_15.docx @ 103424 @ 2 @ 1
7.2 Mounting
Pos: 31 /#Neustruktur #/Online-Dokumen tation/Sicherhei tshinweise und Hinweis e (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_1 5.docx @ 103308 @ @ 1
Warnin
g
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
Work on the 230V supply system may only be performed by authorised electricians!
Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 32 /#Neustruktur #/Modul-Struktur /Online-Dokumenta tion/Montage/al le Geräte/Montage - UP-Dose n - DIN 49073-1 @ 21\mod_13312 10080219_15.doc x @ 202029 @ @ 1
The device must only be installed in suitable flush-mounted sockets (DIN 49073-1).
Pos: 33 /#Neustruktur #/Modul-Struktur /Online-Dokumenta tion/Montage/Di mmer/Montage - 2117 @ 21\mod_1331 210177831_15.doc x @ 202044 @ 2 @ 1
7.3 Inserting optical fibres
Fig. 9:
Insert the optical fibre directly into the two middle openings between the connecting terminals. In the process,
align the plastic lug in the direction of the potentiometer axis.
Hint
The glow lamps included with the control elements must not be used.
The control elements of the impuls series are not suitable for illumination!
Pos: 34 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Steuermodule - Online-Dokumentation (--> Für alle Dokumente <--)/++++++++++++ Seitenumbruc h ++++++++++++ @ 9\mod_1268 898668093_0.docx @ 52149 @ @ 1
! top
3855
3856
Art.
DALI potentiometer for broadcast
operation
Installation and electrical
connection
| 1473-1-7978 — 12 —
Pos: 35 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Überschriften (--> Für alle Dokumente <--)/2. Ebene/A - F/Elektrischer Anschlu ss @ 21\mod_1328177051724 _15.docx @ 138042 @ 2 @ 1
7.4 Electrical connection
Pos: 36 /#Neustruktur #/Modul-Struktur /Online-Dokumen tation/Anschluss/Di mmer/Anschluss - 2117 @ 21\mod_1331205283908 _15.docx @ 202014 @ @ 1
Fig. 10:
No. Function
1 DALI power supply
2 2 DALI operating device
3 2117 U-500
DALI potentiometer for broadcast
operation
Installation and electrical
connection
| 1473-1-7978 — 13 —
Fig. 11:
No. Function
1 DALI operating device
2 2117/11 U-500
Notes
If the DALI potentiometer 2117/11 U-500, is used in installations with an existing DALI power
supply, the terminals L and N must not be assigned. The device is then supplied with current
directly from the bus.
Up to 3 DALI potentiometers 2117/11 U-500 and 5 DALI potentiometers 2117 U-500 can be
operated in parallel. In the process, observe the maximum permissible power consumption.
When DALI operating devices, e.g. electronic ballasts, are connected, the specifications of the
respective manufacturer must be observed.
The DALI control line and mains line may lie together in one NYM cable.
Polyphase operation is permissible.
=== Ende der Liste für Textmarke Content ===
DALI potentiometer for broadcast
operation
1473-1-7978 | | 14.06.2012
Pos: 38 /#Neustruktur#/Modul-Struktur/Online-Dokumentation/Rückseiten (--> Für alle Dokumente <--)/Rückseite - Busch-Jaeger - Allgemein @ 20\mod_1327320074886_1 5.docx @ 137103 @ @ 1
A
member of the ABB Group
Busch-Jaeger Elektro GmbH
PO box
58505 Lüdenscheid
Freisenbergstraße 2
58513 Lüdenscheid
Germany
www.BUSCH-JAEGER.com
Central sales service:
Phone: +49 (0) 180 5 669900
Fax: +49 (0) 180 5 669909
Notice
We reserve the right to at all times make
technical changes as well as changes to the
contents of this document without prior notice.
The detailed specifications agreed to at the time
of ordering apply to all orders. ABB accepts no
responsibility for possible errors or
incompleteness in this document.
We reserve all rights to this document and the
topics and illustrations contained therein. The
document and its contents, or extracts thereof,
must not be reproduced, transmitted or reused by
third parties without prior written consent by ABB.
Copyright© 2012 Busch-Jaeger Elektro GmbH
A
ll rights reserved
=== Ende der Liste für Textmarke Backcover == =
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14

ABB 2117 U-500 Operating instructions

Type
Operating instructions
This manual is also suitable for

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI