Badger Meter Register ILR 750 Programming Manual

Type
Programming Manual

Badger Meter Register ILR 750

Badger Meter Register ILR 750 is an electronic register designed to measure and display the flow rate of liquids. It can be used in a variety of applications, including water and wastewater treatment, chemical processing, and food and beverage production.

The ILR 750 has a number of features that make it a versatile and reliable flow meter. These features include:

  • High accuracy: The ILR 750 is accurate to within ±0.5% of the reading.
  • Wide flow range: The ILR 750 can measure flow rates from 0.01 to 999.99 liters per minute.
  • Multiple display modes: The ILR 750 can display the flow rate, total flow, and remaining flow.

Badger Meter Register ILR 750

Badger Meter Register ILR 750 is an electronic register designed to measure and display the flow rate of liquids. It can be used in a variety of applications, including water and wastewater treatment, chemical processing, and food and beverage production.

The ILR 750 has a number of features that make it a versatile and reliable flow meter. These features include:

  • High accuracy: The ILR 750 is accurate to within ±0.5% of the reading.
  • Wide flow range: The ILR 750 can measure flow rates from 0.01 to 999.99 liters per minute.
  • Multiple display modes: The ILR 750 can display the flow rate, total flow, and remaining flow.
®
Badger Meter Europa GmbH
Register ILR 750
PROGRAMMING MANUAL
October 2018
AC_ILR750_PA_02_1810
Programming Page 1/4
AC_ILR750_PA_02_1810
Programming the electronic ILR750 register
To reach menu item 1 in the programming mode, press the following key combination:
3x then 3x (Keys must be pressed quickly one behind the other!)
Note: You can leave the programming mode any time by pressing the keys „TOTAL“
+ „RESET“ for 2-3 seconds at the same time.
The set data will also be saved.
Menu 1: Programming the calibration factor and the unit of measure
Menu 2: Change meter pulse rate
Menu 3: Register alignment
press for 2-3 seconds
Press „RESET“ to
change the flashing digit
Press „TOTAL“ to
jump to the next digit
Press „RESET“ to
change the flashing digit
Press „TOTAL“ to
jump to the next digit
Predefined pulse rates
RCDL: IOG:
M25 = 52,40 ½“ = 100
M35 = 33,50 ¾“ = 66
M40 = 23,70 1 = 66
M70 = 12,30 1 HF = 43
M120 = 6,30 1 ½“ = 17
M170 = 3,80 2“ = 9
3“ = 3
Programmed pulse rate on figure: 52,40 ppl
Press „RESET“ to
change the flashing digit
Selection of meter type
or rather the alignment:
RCDL und Vision =
o
IOG: Depending
on alignment
I = horizontal
P = vertical
Programming on figure: o (RCDL und Vision)
press for 2-3 seconds
press for 2-3 seconds
Programming Page 2/4
AC_ILR750_PA_02_1810
Menu 4: Change display mode
Menu 5: Analog minimum flow rate
Menu 6: Analog maximum flow rate
Menu 7: Set output pulse duration
Press „RESET“ to
change the flashing digit
Programming line 1 on the display:
C = Totalizer (L, Gal, Qt, Pt)
F = Flow indicator (e.g. L/min)
Note: A totalizer without
decimal places is always in the
second line.
press for 2-3 seconds
Press „RESET“ to
change the flashing digit
Press „TOTAL“ to
jump to the next digit
Flow rate that should be equal to
the 4mA Output:
Minimum: 0,0 l/min
Maximum: 999,8 l/min
Default: 0,0 l/min
The value of the minimum flow rate
must be smaller than the value of
the maximum flow rate (menu 6).
press for 2-3 seconds
Press „RESET“ to
change the flashing digit
Press TOTAL“ to
jump to the next digit
Flow rate that should be equal to
the 20mA output:
Minimum: 0,1 l/min
Maximum: 999,9 l/min
Default: 30,0 l/min
The value of the maximum flow rate
must be higher than the value of
the minimum flow rate (menu 5).
press for 2-3 seconds
Programmed max. flow rate: 30,0 l/min
Press „RESET“ to
change the flashing digit
0 = disabled
2 = 2msec
10 = 10msec
20 = 20msec
40 = 40msec
100 = 100msec
press for 2-3 seconds
Programming Page 3/4
AC_ILR750_PA_02_1810
Menu 8: Pulse frequency
Menu 9: Signal inversion from the pulse output
Menu 10: Linearization
Mit
Press „RESET“ to
change the flashing digit
Press „TOTAL“ to
jump to the next digit
How many pulse/liter should be
delivered?
Pulse output freely scalable from
0,01 999,99 L/min
Programmed pulse frequency on figure: 10,00 ppl
press for 2-3 seconds
Press „RESET“ to
change the flashing digit
IO logical signal sequence
(signal inversion):
1 = Standard setting – (no
inversion) in neutral becomes on
the logical output 1 – e.g. 24V
0 = Output is inverted by software,
in neutral (no pulse at the
output) becomes on the output
logical 0 = 0V
+/- Correction factor in %
(figure: -0,50%)
Linearization point 1
Flow in e.g. l/min
(figure: 3,8 l/min)
In case of an error of +0,50%
the correction factor -0,50% is entered.
Continue with linearization point 2. Same procedure as for linearization point 1.
(At least 3 linearization points have to be programmed, maximum 9 are possible.)
+ press for 2-3 seconds
to close the programming mode and save the data.
press for 2-3 seconds
press for about 2-3 seconds
Hotline
Tel. +49-7025-9208-0 or -46
Fax +49-7025-9208-15
®
Badger Meter Europa GmbH
Subsidiary of Badger Meter, Inc., USA
Nürtinger Strasse 76
72639 Neuffen (Germany)
www.badgermeter.de
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Badger Meter Register ILR 750 Programming Manual

Type
Programming Manual

Badger Meter Register ILR 750

Badger Meter Register ILR 750 is an electronic register designed to measure and display the flow rate of liquids. It can be used in a variety of applications, including water and wastewater treatment, chemical processing, and food and beverage production.

The ILR 750 has a number of features that make it a versatile and reliable flow meter. These features include:

  • High accuracy: The ILR 750 is accurate to within ±0.5% of the reading.
  • Wide flow range: The ILR 750 can measure flow rates from 0.01 to 999.99 liters per minute.
  • Multiple display modes: The ILR 750 can display the flow rate, total flow, and remaining flow.

Ask a question and I''ll find the answer in the document

Finding information in a document is now easier with AI